Fender Bandmaster Owner Manual - Page 7
Corrective, Check - amp
View all Fender Bandmaster manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
REAR PANEL FUNCTIONS A.C. ACcr'^^^'w OUTLET (110-120 V AC, 60 Hz) (Load Limit 200 Watts) This socket is provided as a convenience to be used for any A.C. accessory. UHUUND SWITCH Gives player control of polarity. Position on each side is ground to each side of the A.C. line respectively. The center position disconnects all but the third line chassis ground. Try each position to find the minimum hum. FUSE Caution Disconnect amplifier A.C. plug from outlet before changing fuse. Remove fuse by pressing in and unscrewing cap. Use fuse type specified on chassis back plate. ON/OFF SWITCH Turns amplifier on and off. mnn3BY ovvi I t-ri Allows tube filaments to remain heated during standby periods. Amplification is instantly available without warm-up time. No danger of unwanted sound when in quiet periods. SPEAKER JACK Connects speakers to amplifier. EXTENSION SPEAKS„ JAC„ Provides a connection to an extension speaker enclosure. VIRPATO ANTI PFVFPR lAriec Plug-in connections to pedal and to reverb unit. CORRECTIVE CHECK If your amp is set up but does not function, check the following items: Is the amp power supply cable plugged into the wall? Is there power at the wall outlet where the amp is plugged in? Is the speaker plugged into the amplifier speaker jack? Are the tone control knobs turned up above 4? Is the volume control on your instrument turned up? Is the fuse good? If, after checking all of the above, the system is still not performing correctly, consult your authorized Fender Service Dealer. 5