Fisher and Paykel CPV3-366-N Installation Guide - Page 13

Cooktop burners, Leak testing, Fisher & Paykel Authorized Service Center.

Page 13 highlights

lifting off COOKTOP BURNERS yellow tip stable blue flame LEAK TESTING GAS z To check that the ignition system operates correctly, light each burner by itself, then all burners in combination. z Check for a well-defined blue flame without any yellow tipping. z If any abnormality is evident, check that the components of the burner assembly are located properly. ● No air shutter adjustment is possible on the rangetop. Correct operation is achieved with factory installed settings for the correct gas type. z When installing the burner port ring, align the two locating pins in the bottom side of the port ring with the locating notch and center holes on the top side of the simmer ring, and make sure these are properly engaged. z Incorrect installation may produce a potentially dangerous flame and result in poor burner performance. z If proper operation cannot be obtained, contact Customer Care or your nearest Fisher & Paykel Authorized Service Center. z The rangetop must not be used until proper operation has been achieved. ON z Ensure all dials are set to OFF before connecting rangetop to gas supply. z After final gas connection is made, turn gas supply on and test all connections in gas supply piping for gas leaks with a soapy water solution. z In order to avoid property damage or serious personal injury, never use a match or open flame. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak. air shutter GRILL AND GRIDDLE BURNERS (SOME MODELS ONLY) Each valve and air shutter is individually tested and adjusted prior to shipment. Normally adjustment is not required, however, vibration during transit, gas conversion or variations in the local gas supply may make minor adjustments n­ ecessary. Check for the proper burner flame characteristics and adjust air shutters if necessary. Burner flames should be blue and stable with no yellow tips, excessive noise or lifting of the flame from the burner. If any of these conditions exist, check that the air shutter or burner ports are not blocked. If the condition persists, adjust the air shutter as below: z If the flame is too yellow, indicating insufficient air open the shutter to increase air inlet. z If the flame is noisy or tends to lift away from the burner, indicating too much air, close the shutter to reduce air. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

13
Each valve and air shutter is individually tested and adjusted prior to shipment. Normally adjustment is not required, however,
vibration during transit, gas conversion or variations in the local gas supply may make minor adjustments necessary.
Check for the proper burner flame characteristics and adjust air shutters if necessary. Burner flames should be blue and stable
with no yellow tips, excessive noise or lifting of the flame from the burner. If any of these conditions exist, check that the air
shutter or burner ports are not blocked.
If the condition persists, adjust the air shutter as below:
z
If the flame is too yellow, indicating insufficient air open the shutter to increase air inlet.
z
If the flame is noisy or tends to lift away from the burner, indicating too much air, close the shutter to reduce air.
air shutter
z
Ensure all dials are set to
OFF
before connecting rangetop to gas supply.
z
After final gas connection is made, turn gas supply on and test all connections in gas supply
piping for gas leaks with a soapy water solution.
z
In order to avoid property damage or serious personal injury, never use a match or open
flame. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten
again and retest connection for leak.
ON
GAS
COOKTOP BURNERS
LEAK TESTING
z
To check that the ignition system operates correctly, light each burner by itself, then all
burners in combination.
z
Check for a well-defined blue flame without any yellow tipping.
z
If any abnormality is evident, check that the components of the burner assembly are
located properly.
No air shutter adjustment is possible on the rangetop. Correct operation is achieved with
factory installed settings for the correct gas type.
z
When installing the burner port ring, align the two locating pins in the bottom side of the
port ring with the locating notch and center holes on the top side of the simmer ring, and
make sure these are properly engaged.
z
Incorrect installation may produce a potentially dangerous flame and result in poor
burner performance.
z
If proper operation cannot be obtained, contact Customer Care or your nearest
Fisher & Paykel Authorized Service Center.
z
The rangetop must not be used until proper operation has been achieved.
GRILL AND GRIDDLE BURNERS (SOME MODELS ONLY)
lifting off
stable blue flame
yellow tip