Page 1 highlights

Fluke 114 Electrical Multimeter Technical Data Compact true-rms meter for electrical troubleshooting The Fluke 114 is the troubleshooting tool for "go/no-go" testing. It includes a feature to prevent false readings caused by ghost voltage. Actual size R N10140 Features include: • AutoVolt: automatic ac/dc voltage selection • Large white LED backlight to work in poorly lit areas • Resistance and continuity • Min/Max/Average to record signal fluctuations • CAT III 600 V safety rated General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any terminal and earth ground Surge protection Display Bar graph Operating temperature Storage temperature Battery Battery life 600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Digital: 6,000 counts, updates 4/sec 33 segments, updates 32/sec -10 °C to + 50 °C -40 °C to + 60 °C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight

  • 1
  • 2

Technical Data
Fluke 114
Electrical Multimeter
Features include:
AutoVolt: automatic ac/dc voltage selection
Large white LED backlight to work in poorly lit areas
Resistance and continuity
Min/Max/Average to record signal fluctuations
CAT III 600 V safety rated
Compact true-rms
meter for electrical
troubleshooting
The Fluke 114 is the troubleshooting
tool for “go/no-go” testing. It includes
a feature to prevent false readings
caused by ghost voltage.
General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 95 %.
The accuracy specifications take the form of:
± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between
any terminal and earth
ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4/sec
Bar graph
33 segments, updates 32/sec
Operating temperature
-10 °C to + 50 °C
Storage temperature
-40 °C to + 60 °C
Battery
9 volt Alkaline, NEDA 1604A/
IEC 6LR61
Battery life
400 hours typical, without backlight
N10140
R
Actual size