Selection Table 120 and 190 Series ScopeMeter® Test Tools Bandwidth Max. real time sample rate Equivalent time sample rate Max. record length (per input) Number of inputs Input sensitivity Independently floating isolated inputs Display and Display Modes Display Persistence Envelop Mode Waveform compare FFT Pass/Fail testing Triggering Connect-and-View™ Triggering Edge, single, free run Video Video line select Pulse width External Advanced Functions Cursors Zoom Dual Input TrendPlot™ ScopeRecord™ Mode Automatic capture and replay of last 100 screens Bus Health test mode Advanced Power Measurements Waveform mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz 20 MHz 2.5 GS/s 1.0 GS/s 2.5 GS/s 1.0 GS/s 500 MS/s 25 MS/s 25 MS/s 25 MS/s (covered by real time sample rate) 2.5 GS/s 2.5 GS/s 1.25 GS/s 3000 points 512 points (min/max pairs) 2 scope inputs, 1 DMM input (all fully isolated from each other) 2 scope or DMM inputs 2 mV/div. to 100 V/div. 5 mV/div. to 100 V/div. 5 mV/div. to 50 V/div. • • - Color Monochrome Monochrome Digital persistence with On/Off - variable decay • • • visual + automatic visual only - • - harmonics - mode • - - • • • • • • • • • • • - • • Using optional ITP120 • • • • - • - • - • • - - • - • - • • - - • 10 • - 10 20 20 10 5000 counts, measures volts - amps - ohms - continuity - diode - temperature 1000 V CAT II / 600 V CAT III certified 600 V CAT III certified (1) 4 hours, NiMH 7 hours, NiMH Adapter/battery charger included Using optional Optically Isolated interface cable (either RS-232 or USB) or PAC91 printer adapter cable Three years on instrument / One year on standard accessories (1) Maximum input voltage 1000 V CAT II with VPS40, 40 MHz, 10:1 Voltage Probe (standard included with Fluke 125 and Fluke 124) Detailed technical specifications and optional accessories can be found in the technical datasheet and on the Fluke web site. Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123/S SCC190 SCC120 OC4USB PM9080 SW90W Color ScopeMeter (200 MHz / 2.5 GS/s) Color ScopeMeter (200 MHz / 2.5 GS/s) + SCC190 Color ScopeMeter (100 MHz / 1 GS/s) Color ScopeMeter (100 MHz / 1 GS/s) + SCC190 ScopeMeter (200 MHz / 2.5 GS/s) ScopeMeter (200 MHz / 2.5 GS/s) + SCC190 ScopeMeter (100 MHz / 1 GS/s) ScopeMeter (100 MHz / 1 GS/s) + SCC190 ScopeMeter (60 MHz / 500 MS/s) ScopeMeter (60 MHz / 500 MS/s) + SCC190 Industrial ScopeMeter (40 MHz, with Bus Health) Industrial ScopeMeter (40 MHz, Bus Health) + SCC120 kit) Industrial ScopeMeter (40 MHz) Industrial ScopeMeter (40 MHz) + SCC120 kit Industrial ScopeMeter (20 MHz) Industrial ScopeMeter (20 MHz) + SCC120 kit FlukeView® Software + Cable + Case (190 Series) FlukeView® Software + Cable + Case (120 Series) Optically-isolated USB-interface cable Optically-isolated RS-232 adapter/cable FlukeView® ScopeMeter Software for Windows® • ScopeMeter test tools come standard with a complete accessory package including line voltage adapter and battery pack (installed). ScopeMeter 190B and 190C Series come with probes, probe accessories and multimeter test leads. • Optional accessories ordering information can be found in the technical datasheet or on the Fluke web site. Fluke. Keeping your world up and running.™ Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2004, 2007 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 2/2007 1629090 B-EN-N Rev E

  • 1
  • 2
  • 3
  • 4
  • 5

Selection Table
Fluke 199C
Color ScopeMeter (200 MHz / 2.5 GS/s)
Fluke 199C/S
Color ScopeMeter (200 MHz / 2.5 GS/s) + SCC190
Fluke 196C
Color ScopeMeter (100 MHz / 1 GS/s)
Fluke 196C/S
Color ScopeMeter (100 MHz / 1 GS/s) + SCC190
Fluke 199B
ScopeMeter (200 MHz / 2.5 GS/s)
Fluke 199B/S
ScopeMeter (200 MHz / 2.5 GS/s) + SCC190
Fluke 196B
ScopeMeter (100 MHz / 1 GS/s)
Fluke 196B/S
ScopeMeter (100 MHz / 1 GS/s) + SCC190
Fluke 192B
ScopeMeter (60 MHz / 500 MS/s)
Fluke 192B/S
ScopeMeter (60 MHz / 500 MS/s) + SCC190
Fluke 125
Industrial ScopeMeter (40 MHz, with Bus Health)
Fluke 125/S
Industrial ScopeMeter (40 MHz, Bus Health) + SCC120 kit)
Fluke 124
Industrial ScopeMeter (40 MHz)
Fluke 124/S
Industrial ScopeMeter (40 MHz) + SCC120 kit
Fluke 123
Industrial ScopeMeter (20 MHz)
Fluke 123/S
Industrial ScopeMeter (20 MHz) + SCC120 kit
SCC190
FlukeView
®
Software + Cable + Case (190 Series)
SCC120
FlukeView
®
Software + Cable + Case (120 Series)
OC4USB
Optically-isolated USB-interface cable
PM9080
Optically-isolated RS-232 adapter/cable
SW90W
FlukeView
®
ScopeMeter Software for Windows
®
ScopeMeter test tools come standard with a complete accessory package including line
voltage adapter and battery pack (installed). ScopeMeter 190B and 190C Series come
with probes, probe accessories and multimeter test leads.
Optional accessories ordering information can be found in the technical datasheet or
on the Fluke web site.
Ordering information
Bandwidth
Max. real time sample rate
Equivalent time sample rate
Max. record length (per input)
Number of inputs
Input sensitivity
Independently floating
isolated inputs
Display and Display Modes
Display
Persistence
Envelop Mode
Waveform compare
FFT
Pass/Fail testing
Triggering
Connect-and-View™ Triggering
Edge, single, free run
Video
Video line select
Pulse width
External
Advanced Functions
Cursors
Zoom
Dual Input TrendPlot™
ScopeRecord™ Mode
Automatic capture and replay
of last 100 screens
Bus Health test mode
Advanced Power
Measurements
Waveform mathematics
Save set-ups and screens
True-rms multimeter
Safety, Power and Warranty
Safety (EN61010-1)
Battery
Line power
PC and printer interface
Warranty
190C ScopeMeter Series
190B ScopeMeter Series
1±0 Series
Fluke 199C
Fluke 19µC
Fluke 199B
Fluke 19µB
Fluke 19±B
Fluke 1±´
Fluke 1±³
Fluke 1±²
200 MHz
100 MHz
200 MHz
100 MHz
60 MHz
40 MHz
40 MHz
20 MHz
2.5 GS/s
1.0 GS/s
2.5 GS/s
1.0 GS/s
500 MS/s
25 MS/s
25 MS/s
25 MS/s
(covered by real time sample rate)
2.5 GS/s
2.5 GS/s
1.25 GS/s
3000 points
512 points (min/max pairs)
2 scope inputs, 1 DMM input (all fully isolated from each other)
2 scope or DMM inputs
2 mV/div. to 100 V/div.
5 mV/div. to 100 V/div.
5 mV/div. to 50 V/div.
Color
Monochrome
Monochrome
Digital persistence with
On/Off
variable decay
visual + automatic
visual only
h
armonics
mode
Using optional ITP120
10
10
20
20
10
5000 counts, measures volts – amps – ohms – continuity – diode – temperature
1000 V CAT II / 600 V CAT III certified
600 V CAT III certified
(1)
4 hours, NiMH
7 hours, NiMH
Adapter/battery charger included
Using optional Optically Isolated interface cable (either RS-232 or USB) or PAC91 printer adapter cable
Three years on instrument / One year on standard accessories
(1)
Maximum input voltage 1000 V CAT II with VPS40, 40 MHz, 10:1 Voltage Probe (standard included with Fluke 125 and Fluke 124)
Detailed technical specifications and optional accessories can be found in the technical datasheet and on the Fluke web site.
1±0 and 190 Series ScopeMeter
®
Test Tools
Fluke Corporation
PO Box 9090,
Everett, WA USA 98206
Fluke.
Keeping your world up and running.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
©2004, 2007 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 2/2007 1629090 B-EN-N Rev E