Fluke 124B User Manual - Page 81

Dual Input Meter, Screen Update, Source, Sensitivity A and B, Slope, Display Modes

Page 81 highlights

Industrial ScopeMeter® Specifications Trigger Screen Update Free Run, On Trigger Source A, B Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV @ 40 MHz 125B, 124B 1.5 divisions 123B 4 divisions @ 60 MHz 125B, 124B 4 divisions 123B NA Slope Positive, Negative Advanced Scope Functions Display Modes Normal Captures up to 25 ns glitches and displays analog-like persistence waveform. Smooth Suppresses noise from a waveform. Envelope Records and displays the minimum and maximum of waveforms over time. Auto Set (Connect-and-View) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level. Dual Input Meter The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C. Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1 %. More than one waveform period must be visible on the screen. 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Industrial ScopeMeter®
Specifications
71
Trigger
Screen Update
.......................................................
Free Run, On Trigger
Source
....................................................................
A, B
Sensitivity A and B
@ DC to 5 MHz
...................................................
0.5 divisions or 5 mV
@ 40 MHz
125B, 124B
.....................................................
1.5 divisions
123B
................................................................
4 divisions
@ 60 MHz
125B, 124B
.....................................................
4 divisions
123B
................................................................
NA
Slope
.......................................................................
Positive, Negative
Advanced Scope Functions
Display Modes
Normal
.................................................................
Captures up to 25 ns glitches and displays analog-like persistence waveform.
Smooth
................................................................
Suppresses noise from a waveform.
Envelope
.............................................................
Records and displays the minimum and maximum of waveforms over time.
Auto Set (Connect-and-View
)
Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user
adjustment of amplitude, time base, or trigger level.
Dual Input Meter
The accuracy of all measurements is within
±
(% of reading + number of counts) from 18
°
C to 28
°
C.
Add 0.1x (specific accuracy) for each
°
C below 18
°
C or above 28
°
C. For voltage measurements with 10:1 probe, add probe uncertainty
+1 %. More than one waveform period must be visible on the screen.