Fluke 1550B Fluke 1550B MegOhmMeter Datasheet - Page 2

Electrical specifications, Mechanical specifications, Power, Environmental specifications, Software - enclosure

Page 2 highlights

Specifications Electrical specifications Environmental specifications The meter's accuracy is specified for one year after calibration at operating temperatures of 0 °C to 35 °C. For operating temperatures outside the range (-20 °C to 0 °C and 35 °C to 50 °C), add +/- .25 % per °C, except on the 20 % bands add +/- 1 % per °C. Insulation resistance measurement Test Voltage (dc) 250 V 500 V 1000 V 2500 V 5000 V Range 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ Accuracy (± reading) 5 % 20 % 5 % 20 % 5 % 20 % 5 % 20 % 5 % 20 % Short circuit current Bar graph range Insulation test voltage accuracy Induced ac mains current rejection Charging rate for capacitive load greater than 1 mA and less than 2 mA 0 to 1 TΩ -0 % to +10 % at 1 mA load current 2 mA maximum 5 seconds per µF Leakage current Capacitance measurement Live circuit indicator Range 1 nA to 2 mA 0.01 uF to 15.00 µF Accuracy ± (5 % + 2 nA) ± (15 % rdg + 0.03 µF) 30 V to 600 V ac/dc, 50/60 Hz ± (5 % + 2 V) Operating temperature Storage temperature Relative humidity Operating altitude Enclosure sealing Shock, vibration EMI immunity Safety Input overload protection -20 °C to 50 °C (-4 °F to 122 °F) -20 °C to 65 °C (-4 °F to 149 °F) 80 % at 31 °C decreasing linearly to 50 % at 50 °C 0 to 2000 meters IP-40 MIL-PRF-28800F, CLASS II EN 61326 EN 61010-1, CAT III, 600 V, EN61557, PARTS 1 & 2 600 V ac continuous Software specifications Quicklink 1550B Software requires a PC running Windows® 95, 98, Me, 2000, NT4.0 Two-year warranty Included accessories Test leads and low leakage probes Alligator clips Interface adapter and cable Quicklink 1550B PC software Line cord Soft carrying case with waterproof bottom User's manual CD with 12 languages Getting Started Guide Optional accessories 25 foot extension leads Timer Ramp 0 to 99 minutes; settable in 1 minute increments; indicated to within 1 second 0 % to 100 % of selected test voltage, or until breakdown Mechanical specifications Dimensions (L x W x H) Weight (with battery) 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13.0 in) 4 kg (8.8 lbs) Power Battery type 12 volt, lead-acid, rechargeable Charger input (AC) 85 to 250 V ac 50/60 Hz 50 VA Battery life (typical) Note: At higher temperatures, the battery requires more frequent charging. Test voltages 250 V 500 V 1 kV 2.5 kV 5 kV Number of tests 4138 3913 3462 2043 1000 Fluke. Keeping your world up and running. Authorized Distributor OptimuFmlukEe nCeorrpgoyraPtiroonducts Ltd. PO Box 9090, Everett, WA USA 98206 333, 11Fl9u7ke9 E-u4ro0ptehBS.Vtr.eet S.E. CalgarPyO, ABolxbe11r8ta6, 5T620Z2 B4DM3 Eindhoven, The Netherlands Toll FreFInoerth8me7oU7r.eS-7.iAn6.fo6(8r-0m50a4)t1i4o24n3-c5a8ll5: 3 or Main 4F0a3x -(242556)-434663-56116 Fax 40IF3na-xE2u(35r1o6p4-e30/)M423-E16a7s5t/2A2fr2ica (31 40) 2 675 200 or In Canada (800)-36-FLUKE or info@oFFparoxtmim(9o0ut5hm)er8e9cno0eu-n6rgt8r6iye6.sc+o1m(425) 446-5500 or www.MFayxF+l1uk(4e2S5)to4r4e6.-c5o11m6 Web access: http://www.fluke.com/ ©2003 Fluke Corporation. All rights reserved. Trademarks are the property of their respective owners. Printed in U.S.A. 10/2003 1629685 D-ENG-N Rev D

  • 1
  • 2

Short circuit current
greater than 1 mA and less than 2 mA
Bar graph range
0 to 1 T
Insulation test voltage
-0 % to +10 % at 1 mA load current
accuracy
Induced ac mains
2 mA maximum
current rejection
Charging rate for
5 seconds per μF
capacitive load
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
©2003 Fluke Corporation. All rights reserved.
Trademarks are the property of their respective owners.
Printed in U.S.A.
10/2003
1629685 D-ENG-N Rev D
Fluke.
Keeping your world
up and running.
Specifications
Electrical specifications
The meter’s accuracy is specified for one year
after calibration at operating temperatures of 0
°C to 35 °C. For operating temperatures outside
the range (-20 °C to 0 °C and 35 °C to 50 °C),
add +/- .25 % per °C, except on the 20 % bands
add +/- 1 % per °C.
Insulation resistance measurement
Test Voltage
Range
Accuracy
(dc)
(± reading)
250 V
200 k
to 5 G
5 %
5 G
to 50 G
20 %
500 V
200 k
to 10 G
5 %
10 G
to 100 G
20 %
1000 V
200 k
to 20 G
5 %
20 G
to 200 G
20 %
2500 V
200 k
to 50 G
5 %
50 G
to 500 G
20 %
5000 V
200 k
to 100 G
5 %
100 G
to 1 T
20 %
Timer
0 to 99 minutes; settable in 1 minute increments;
indicated to within 1 second
Ramp
0 % to 100 % of selected test voltage, or until
breakdown
Mechanical specifications
Dimensions (L x W x H)
170 mm x 242 mm x 330 mm
(6.7 in x 9.5 in x 13.0 in)
Weight (with battery)
4 kg (8.8 lbs)
Power
Battery type
12 volt, lead-acid, rechargeable
Charger input (AC)
85 to 250 V ac 50/60 Hz 50 VA
Battery life (typical)
T
est voltages
Numb
er of tests
Note: At higher temperatures,
250 V
4138
the battery requires more
500 V
3913
frequent charging.
1 kV
3462
2.5 kV
2043
5 kV
1000
Environmental specifications
Operating temperature
-20 °C to 50 °C (-4 °F to 122 °F)
Storage temperature
-20 °C to 65 °C (-4 °F to 149 °F)
Relative humidity
80 % at 31°C decreasing linearly
to 50 % at 50 °C
Operating altitude
0 to 2000 meters
Enclosure sealing
IP-40
Shock, vibration
MIL-PRF-28800F, CLASS II
EMI immunity
EN 61326
Safety
EN 61010-1, CAT III, 600 V,
EN61557, PARTS 1 & 2
Input overload protection
600 V ac continuous
Software specifications
Quicklink 1550B Software requires a PC running
Windows
®
95, 98, Me, 2000, NT4.0
Two-year warranty
Included accessories
Test leads and low leakage probes
Alligator clips
Interface adapter and cable
Quicklink 1550B PC software
Line cord
Soft carrying case with
waterproof bottom
User’s manual CD with 12 languages
Getting Started Guide
Optional accessories
25 foot extension leads
Range
Accuracy
Leakage current
1 nA to 2 mA
± (5 % + 2 nA)
Capacitance
0.01 uF to 15.00 μF
± (15 % rdg + 0.03 μF)
measurement
Live circuit
30 V to 600 V
± (5 % + 2 V)
indicator
ac/dc, 50/60 Hz
Authorized Distributor
Optimum Energy Products Ltd.
333, 11979 - 40th Street S.E.
Calgary, Alberta
T2Z 4M3
Toll Free 877-766-5412
Main 403-256-3636
Fax 403-256-3431
www.MyFlukeStore.com