Fluke 1587 FE 1587-1577 Users Manual - Page 40

Electrical Specifications, AC Voltage Measurement, 1587 and 1587T Accuracy

Page 40 highlights

1587/1577 Users Manual Altitude Operating 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V Storage 12,000 m Over-Range Capability 110% of range except for capacitance which is 1 % Compliance to EN 61557 IEC61557-1, IEC61557-2 Electrical Specifications AC Voltage Measurement 1587 and 1587T Accuracy Range Resolution 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V [1] 1 kHz bandwidth. 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz to 60 Hz ± (% of Rdg + Digits) + (1 % + 3) + (1 % + 3) + (1 % + 3) + (1 % + 3) + (2 % + 3) 60 Hz to 5000 Hz ± (% of Rdg + Digits) + (2 % + 3) + (2 % + 3) + (2 % + 3) + (2 % + 3) [1] + (2 % + 3) [1] 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

1587/1577
Users Manual
30
Altitude
Operating
........................................................
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Storage
............................................................
12,000 m
Over-Range Capability
........................................
110% of range except for capacitance which is 1 %
Compliance to EN 61557
....................................
IEC61557-1, IEC61557-2
Electrical Specifications
AC Voltage Measurement
1587 and 1587T Accuracy
Range
Resolution
50 Hz to 60 Hz
±
(% of Rdg + Digits)
60 Hz to 5000 Hz
±
(% of Rdg + Digits)
600.0 mV
0.1 mV
+
(1 % + 3)
+
(2 % + 3)
6.000 V
0.001 V
+
(1 % + 3)
+
(2 % + 3)
60.00 V
0.01 V
+
(1 % + 3)
+
(2 % + 3)
600.0 V
0.1 V
+
(1 % + 3)
+
(2 % + 3)
[1]
1000 V
1 V
+
(2 % + 3)
+
(2 % + 3)
[1]
[1]
1 kHz bandwidth.