Fluke 177/EFSP Manual - Page 17

Function, Range, Resolution, Model 175, 0 mA accuracy specified up to 600 mA overload.

Page 17 highlights

True RMS Multimeters Specifications Function DC Amps4 Hz (AC- or DCcoupled, V or A 2, 3 input ) Temperature MIN MAX AVG Range 1 60.00 mA 400.0 mA6 6.000 A 10.00 A7 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz Resolution 0.01 mA 0.1 mA 0.001 A 0.01 A 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz Accuracy ±( [ % of Reading ] + [ Counts ] ) Model 175 Model 177 Model 179 1.0 % + 3 1.0 % + 3 1.0 % + 3 0.1 % + 1 0.1 % + 1 0.1 % + 1 -40 °C to +400 °C -40 °F to +752 °F 0.1 °C 0.1 °F NA NA 1 % + 105 1 % + 185 For DC functions, accuracy is the specified accuracy of the measurement function ±12 counts for changes longer than 350 ms in duration. For AC functions, accuracy is the specified accuracy of the measurement function ±40 counts for changes longer than 900 ms in duration. 1. All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range. 2. Frequency is specified from 2 Hz to 99.99 kHz in Volts and from 2 Hz to 30 kHz in Amps. 3. Below 2 Hz, the display shows zero Hz. 4. Amps input burden voltage (typical): 400 mA input 2 mV/A, 10 A input 37 mV/A. 5. Does not include error of the thermocouple probe. 6. 400.0 mA accuracy specified up to 600 mA overload. 7. > 10A unspecified. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

True RMS Multimeters
Specifications
13
Accuracy ±( [ % of Reading ] + [ Counts ] )
Function
Range
1
Resolution
Model 175
Model 177
Model 179
DC Amps
4
60.00 mA
400.0 mA
6
6.000 A
10.00 A
7
0.01 mA
0.1 mA
0.001 A
0.01 A
1.0 % + 3
1.0 % + 3
1.0 % + 3
Hz
(AC- or DC-
coupled, V or
A
2, 3
input )
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 1
0.1 % + 1
0.1 % + 1
Temperature
-40
°
C to +400
°
C
-40
°
F to +752
°
F
0.1
°
C
0.1
°
F
NA
NA
1 % + 10
5
1 % + 18
5
MIN MAX AVG
For DC functions, accuracy is the specified accuracy of the measurement function
±
12 counts for changes longer than 350 ms in
duration.
For AC functions, accuracy is the specified accuracy of the measurement function
±
40 counts for changes longer than 900 ms in
duration.
1.
All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range.
2.
Frequency is specified from 2 Hz to 99.99 kHz in Volts and from 2 Hz to 30 kHz in Amps.
3.
Below 2 Hz, the display shows zero Hz.
4.
Amps input burden voltage (typical): 400 mA input 2 mV/A, 10 A input 37 mV/A.
5.
Does not include error of the thermocouple probe.
6.
400.0 mA accuracy specified up to 600 mA overload.
7.
> 10A unspecified.