Fluke 289 Fluke 289 Digital Multimeter Product Datasheet - Page 2

The new Fluke 289 True-rms, Industrial Logging Multimeter, with TrendCapture - cable

Page 2 highlights

The new Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture maximizes plant productivity in the most demanding industrial settings. Solve problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment. The Fluke 289 puts powerful diagnostic capabilities in your hands, and helps you take troubleshooting and predictive maintenance to the next level. It is the ultimate handheld tool for any difficult application that requires precision and true-rms accuracy combined with a large graphic display. The Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture includes all the advanced digital multimeter features you'd expect from a Fluke tool plus: • Large 50,000 count, 1/4 VGA display with white backlight for fast, accurate viewing of measurements • Logging Function with TrendCapture plots measurements as a single line to help detect anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings on the meter • "i" button Unsure about a measurement function? Select it, then press the "i" button for instant access to on-board help screens • Log multiple sessions or log data continuously for over 200 hours TrendCapture displays V dc logged date • LoZ low input impedance prevents false readings due to "ghost voltage." It is also the recommended mode when testing for absence or presence of live power • Low Pass filter helps you make accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment • 50 Ohm Range useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current "i" button provides instant on-screen help • Soft keys and scroll buttons for easy navigation control, access to secondary functions. Create custom displays too • Saved measurements for naming and recalling measurements made in the field • Field upgradeable and expandable meter lets you stay current as new capabilities are added • Events and trends recording Helpful for trouble- shooting intermittent problems or profiling loads 0.025 % basic dc accuracy allows you to measure with confidence. FlukeView Forms software compatible with built-in IR Port Simple user-defined interface to save, name, & recall measurements "Softkey" interface dramatically enhances ease of use "i" button "i" button provides instant on-screen help Specifications: Function Range & Resolution Basic Accuracy DC Volts AC Volts 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V 0.025 % 0.4 % (true-rms) DC Current AC Current 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A 0.15 % 0.7 % (true-rms) Temperature -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) (excluding probe) 1.0 % Resistance Capacitance 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF 0.05 % 1.0 % Frequency 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz 0.005 % For more detailed specifications go to www.fluke.com/289 N10140 Transfer data to PC using optional cable and FlukeView Forms Software Image depicts Lo Ohms measurement on nonenergized motor.

  • 1
  • 2
  • 3

The new Fluke 289 True-rms
Industrial Logging Multimeter
with TrendCapture
maximizes plant productivity
Large 50,000 count, 1/4 VGA
display with
white backlight for fast, accurate viewing of
measurements
Logging Function with TrendCapture
plots
measurements as a single line to help detect
anomalies over time, storing up to 10,000
readings. Using on-board TrendCapture, you can
graphically view logged readings on the meter
“i” button
Unsure about a measurement function?
Select it, then press the “i” button for instant
access to on-board help screens
Log multiple sessions or log data
continuously for over 200 hours
LoZ
low input impedance prevents false readings
due to “ghost voltage.” It is also the recommended
mode when testing for absence or presence of
live power
Low Pass filter
helps you make accurate voltage
and frequency measurements on adjustable
speed motor drives and other electrically noisy
equipment
50 Ohm Range
useful for measuring and
comparing differences in motor winding
resistance, low ohm measurements, or other
contact resistance. Two terminal 50 ohm range
with 1 milliohm resolution, 10 mA source current
Soft keys and scroll buttons for easy
navigation control,
access to secondary
functions. Create custom displays too
Saved measurements
for naming and recalling
measurements made in the field
Field upgradeable
and expandable meter lets
you stay current as new capabilities are added
Events and trends recording
Helpful for trouble-
shooting intermittent problems or profiling loads
in the most demanding industrial settings. Solve problems on motor
drives, in-plant automation, power distribution and electro-mechanical
equipment. The Fluke 289 puts powerful diagnostic capabilities
in your hands, and helps you take
troubleshooting and predictive
maintenance to the next level. It is the ultimate handheld tool for
any difficult application that requires precision and true-rms
accuracy combined with a large graphic display.
The Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
includes all the advanced digital multimeter features you’d expect from a
Fluke tool plus:
TrendCapture displays V dc logged date
“i” button provides instant on-screen help
0.025 % basic dc accuracy allows you
to measure with confidence.
Transfer data to PC using
optional cable and FlukeView
Forms Software
Image depicts Lo Ohms
measurement on
nonenergized motor.
FlukeView Forms
software compatible with built-in IR Port
Simple user-defined interface
to save, name, & recall measurements
“Softkey” interface
dramatically enhances ease of use
”i” button
“i” button provides instant on-screen help
Specifications:
Function
Range & Resolution
Basic Accuracy
DC Volts
50.000 mV,500.00 mV, 5.0000 V, 50.000 V,
0.025 %
AC Volts
500.00 V, 1000.0V
0.4 %
(true-rms)
DC Current
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA,
0.15 %
AC Current
5.0000 A, 10.000 A
0.7 %
(true-rms)
Temperature
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
1.0 %
(excluding probe)
Resistance
50.000
Ω
, 500.00
Ω
, 5.0000 k
Ω
, 50.000 k
Ω
,
0.05 %
500.00 k
Ω
, 5.0000 M
Ω
, 50.00 M
Ω
, 500.0 M
Ω
Capacitance
1.000 nF,10.00 nF
100.0 nF, 1.000 µF, 10.00 µF,
1.0 %
100.0 µF, 1000 µF, 10.00 mF, 100.00 mF
Frequency
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
0.005 %
For more detailed specifications go to www.fluke.com/289
N10140