430 Series II Power Quality and Energy Analyzer selection table Model Standard compliance Volt Amp Hz Dips and swells Harmonics Power and energy Energy loss calculator Unbalance Monitor Inrush Event waveform capture Flicker Transients Mains signaling Power wave Power inverter efficiency 400Hz C1740 Soft Case C437-II Hard Case with rollers SD card (Max 32 GB) Fluke 434-II IEC 61000-4-30 Class S • • 8 GB Fluke 435-II IEC 61000-4-30 Class A • 8 GB Fluke 437-II IEC 61000-4-30 Class A • 8 GB All models include the following accessories TL430 test lead set, 4 x i430 thin flexi current probes, BP290 battery, BC430 power adapter with international power adapter set, USB cable A-B mini and PowerLog CD. Technical specifications Specifications are valid for models Fluke 434-II, Fluke 435-II, Fluke 437-II unless otherwise specified. Specificatons for Amp and Watt readings are based upon i430-Flexi-TF unless otherwise specified. Input characteristics Voltage inputs Number of inputs Maximum input voltage Nominal voltage range Max. peak measurement voltage Input impedance Bandwidth Scaling Current inputs Number of inputs Type Range Input impedance Bandwidth Scaling 4 (3 phase + neutral) dc-coupled 1000 Vrms Selectable 1 V to 1000 V 6 kV (transient mode only) 4 MΩ//5 pF > 10 kHz, up to 100 kHz for transient mode 1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable 4 (3 phase + neutral) dc- or ac-coupled Clamp or current transformer with mV output or i430flex-TF 0.5 Arms to 600 Arms with included i430flex-TF (with sensitivity 10x) 5 Arms to 6000 Arms with included i430flex-TF (with sensitivity 1x) 0.1 mV/A to 1 V/A and custom for use with optional ac or dc clamps 1 MΩ > 10 kHz 1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable MyFlukeStore 1.877.766.5412 www. 3 FluSkehCooprpofroatrioFnlukFelukper4o30duSecritess IoI Tnhrleine-ePhaaste: Energy and Power Quality Analyzers .com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Technical specifications
Specifications are valid for models Fluke 434-II, Fluke 435-II, Fluke 437-II unless otherwise specified.
Specificatons for Amp and Watt readings are based upon i430-Flexi-TF unless otherwise specified.
Input characteristics
Voltage inputs
Number of inputs
4 (3 phase + neutral) dc-coupled
Maximum input voltage
1000 Vrms
Nominal voltage range
Selectable 1 V to 1000 V
Max. peak measurement voltage
6 kV (transient mode only)
Input impedance
4 MΩ//5 pF
Bandwidth
> 10 kHz, up to 100 kHz for transient mode
Scaling
1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable
Current inputs
Number of inputs
4 (3 phase + neutral) dc- or ac-coupled
Type
Clamp or current transformer with mV output or i430flex-TF
Range
0.5 Arms to 600 Arms with included i430flex-TF (with sensitivity 10x)
5 Arms to 6000 Arms with included i430flex-TF (with sensitivity 1x)
0.1 mV/A to 1 V/A and custom for use with optional ac or dc clamps
Input impedance
1 MΩ
Bandwidth
> 10 kHz
Scaling
1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable
430 Series II Power Quality and Energy Analyzer selection table
Model
Fluke 434-II
Fluke 435-II
Fluke 437-II
Standard compliance
IEC 61000-4-30 Class S
IEC 61000-4-30 Class A
IEC 61000-4-30 Class A
Volt Amp Hz
Dips and swells
Harmonics
Power and energy
Energy loss calculator
Unbalance
Monitor
Inrush
Event waveform capture
Flicker
Transients
Mains signaling
Power wave
Power inverter efficiency
400Hz
C1740 Soft Case
C437-II Hard Case with rollers
SD card (Max 32 GB)
8 GB
8 GB
8 GB