Fluke 437-II Manual - Page 10

Contacting a Service Center, Safety Information: Read First, Warning, Caution - 437 series ii

Page 10 highlights

Fluke 434-II/435-II/437-II Users Manual # Description 1 Power Quality Analyzer Fluke 43x Series II + Side Strap, Battery Pack BP290 (28 Wh) and 8 GB SD Memory Card Installed 2 Decal Set for Input Sockets (EU & UK, EU, China, UK, US, Canada) 3 Hang Strap 4 Alligator Clips. Set of 5 5 Test Leads, 2.5 m + Color Coding Clips. Set of 5 6 Power Adapter 7 Line Plug Adapter Set (EU, US, UK, Australia/China, Switzerland, Brazil, Italy) or Regional Power Cord. 8 Safety Instructions Booklet (Multi-Language) 9 CD-ROM with Manuals (Multi-Language), PowerLog Software, and USB drivers 10 USB Interface Cable for PC Connection (USB-A to mini-USB-B) 11 Flexible 6000 A AC Current Probe (not in Basic Version) Fluke 434-II/435-II: Fluke 437-II: 12 Soft Carrying Case C1740 Hard Case with Rollers C437-II Contacting a Service Center To locate a Fluke authorized service center, visit us on the World Wide Web at: www.fluke.com or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in the U.S. and Canada +31-40-2675200 in Europe +1-425-446-5500 from other countries Safety Information: Read First The Fluke 434-II/435-II/437-II Three Phase Energy and Power Quality Analyzer complies with: IEC/EN61010-1-2001, CAN/CSA C22.2 No 61010-1-04 (including cCSAus approval), UL std No 61010-1, Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements, Rated: 600V CAT IV 1000V CAT III Pollution Degree 2. Use the Analyzer and its accessories only as specified in the Users Manual. Otherwise, the protection provided by the Analyzer and its accessories might be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the Analyzer. The following international symbols are used on the Analyzer and in this manual: 1-4 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

Fluke 434-II/435-II/437-II
Users Manual
1-4
#
Description
1
Power Quality Analyzer Fluke 43x Series II + Side Strap, Battery Pack BP290 (28 Wh) and 8 GB
SD Memory Card Installed
2
Decal Set for Input Sockets (EU & UK, EU, China, UK, US, Canada)
3
Hang Strap
4
Alligator Clips. Set of 5
5
Test Leads, 2.5 m + Color Coding Clips. Set of 5
6
Power Adapter
7
Line Plug Adapter Set (EU, US, UK, Australia/China, Switzerland, Brazil, Italy) or Regional Power
Cord.
8
Safety Instructions Booklet (Multi-Language)
9
CD-ROM with Manuals (Multi-Language), PowerLog Software, and USB drivers
10
USB Interface Cable for PC Connection (USB-A to mini-USB-B)
11
Flexible 6000 A AC Current Probe (not in Basic Version)
Fluke 434-II/435-II:
Fluke 437-II:
12
Soft Carrying Case C1740
Hard Case with Rollers C437-II
Contacting a Service Center
To locate a Fluke authorized service center, visit us on the World Wide Web at:
www.fluke.com
or call Fluke using any of the phone numbers listed below:
+1-888-993-5853 in the U.S. and Canada
+31-40-2675200 in Europe
+1-425-446-5500 from other countries
Safety Information: Read First
The Fluke 434-II/435-II/437-II Three Phase Energy and Power Quality Analyzer
complies with:
IEC/EN61010-1-2001,
CAN/CSA C22.2 No 61010-1-04 (including
c
CSA
us
approval),
UL std No 61010-1,
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory
Use, Part 1: General requirements, Rated: 600V CAT IV 1000V CAT III Pollution
Degree 2.
Use the Analyzer and its accessories only as specified in the
Users Manual
. Otherwise,
the protection provided by the Analyzer and its accessories might be impaired.
A
Warning
identifies conditions and actions that pose hazard(s) to the user.
A
Caution
identifies conditions and actions that may damage the Analyzer.
The following international symbols are used on the Analyzer and in this manual:
Shop for Fluke products online at:
1.877.766.5412
www.
MyFlukeStore
.com