Fluke 51 Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet - Page 1

Fluke 51 Manual

Page 1 highlights

50 Series II Thermometers Fluke 54 II Laboratory accuracy. Wherever you go. The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool. • Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only) plus MIN, MAX, or AVG • Relative time clock on MIN, MAX, and AVG provides a time reference for major events • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy • Readout in °C, °F, or Kelvin (K) • Sleep mode increases battery life • Battery door allows easy battery replacement without breaking the calibration seal Additional features for the 53 and 54 Series II: • Data Logging up to 500 points of data with user adjustable recording interval • Real time clock captures the exact time of day when events occur • Recall function allows logged data to be easily reviewed on the meter display • IR communication port allows data to be exported to optional FlukeView® Temperature PC software Features Thermocouple types Number of inputs Time stamp Splash/Dust resistant Dual display with backlight Min/Max/Avg recording (T1-T2) True differential Data logging up to 500 points IR data port for interface to PC Compatible with optional FlukeView Software 51 II J,K,T,E Single Relative Time ● ● ● 52 II J,K,T,E Dual Relative Time 53 II J,K,T,E,N,R,S Single Time of Day ● ● ● ● ● ● 54 II J,K,T,E,N,R,S Dual Time of Day ● Fluke 51 II Fluke 52 II Fluke 53 II Included Accessories Impact absorbing holster Two bead probe thermocouples 80PK-1 (54+52) One bead probe thermocouple 80PK-1 (51+53) Ordering Information Fluke 51 II Thermometer Fluke 52 II Thermometer Fluke 53 II Thermometer Fluke 54 II Thermometer FVF-SC1 FlukeView Forms Software including interface cable Specifications Temperature range: J-type Thermocouples K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples R** and S-type** Thermocouples Temperature accuracy Above -100°C (-148°F): J, K, T, E, and N-type** R** and S-type** Below -100°C (-148°F): J, K, E, and N-types T-type -210°C to 1200°C -200°C to 1372°C -250°C to 400°C -150°C to 1000°C -200°C to 1300°C 0°C to 1767°C (-346°F to 2192°F) (-328°F to 2501°F) (-418°F to 752°F) (-238°F to 1832°F) (-328°F to 2372°F) (32°F to 3212°F) ± [ 0.05% + 0.3°C (0.5°F) ] ± [ 0.05% + 0.4°C (0.7°F) ] ± [ 0.20% + 0.3°C (0.5°F) ] ± [ 0.50% + 0.3°C (0.5°F) ] **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples. Battery life: 1000 hours typical, AA Size (HxWxD): 173 x 86 x 38 mm Weight: 0.4 kg Three Year Warranty Recommended Accessories 11080-eng Rev. 01 C25 80PK-26 80PK-25 FVF-SC1 TPAK

  • 1

C25
80PK-26
80PK-25
FVF-SC1
TPAK
50 Series II Thermometers
Laboratory accuracy. Wherever you go.
Additional features for the 53 and
54 Series II:
Data Logging up to 500 points of data
with user adjustable recording interval
Real time clock captures the exact time of
day when events occur
Recall function allows logged data to be
easily reviewed on the meter display
IR communication port allows data to be
exported to optional FlukeView
®
Temperature PC software
Features
Specifications
Recommended Accessories
Battery life:
1000 hours typical, AA
Size (HxWxD):
173 x 86 x 38 mm
Weight:
0.4 kg
Three Year Warranty
11080-eng
Rev. 01
Included Accessories
Impact absorbing holster
Two bead probe thermocouples 80PK-1
(54+52)
One bead probe thermocouple 80PK-1
(51+53)
Ordering Information
Fluke 51 II
Thermometer
Fluke 52 II
Thermometer
Fluke 53 II
Thermometer
Fluke 54 II
Thermometer
FVF-SC1
FlukeView Forms
Software including
interface cable
51 II
52 II
53 II
54 II
Thermocouple types
J,K,T,E
J,K,T,E
J,K,T,E,N,R,S
J,K,T,E,N,R,S
Number of inputs
Single
Dual
Single
Dual
Time stamp
Relative Time
Relative Time
Time of Day
Time of Day
Splash/Dust resistant
Dual display with backlight
Min/Max/Avg recording
(T
1
-T
2
) True differential
Data logging up to 500 points
IR data port for interface
to PC
Compatible with optional
FlukeView Software
Temperature range:
J-type
Thermocouples
-210°C to 1200°C
(-346°F to 2192°F)
K-type
Thermocouples
-200°C to 1372°C
(-328°F to 2501°F)
T-type
Thermocouples
-250°C to 400°C
(-418°F to 752°F)
E-type
Thermocouples
-150°C to 1000°C
(-238°F to 1832°F)
N-type**
Thermocouples
-200°C to 1300°C
(-328°F to 2372°F)
R** and S-type** Thermocouples
0°C to 1767°C
(32°F to 3212°F)
Temperature accuracy
Above –100°C (-148°F):
J, K, T, E, and N-type**
± [ 0.05% + 0.3°C (0.5°F) ]
R** and S-type**
± [ 0.05% + 0.4°C (0.7°F) ]
Below –100°C (-148°F):
J, K, E, and N-types
± [ 0.20% + 0.3°C (0.5°F) ]
T-type
± [ 0.50% + 0.3°C (0.5°F) ]
**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples.
The Fluke 50 Series II contact
thermometers offer fast response and
laboratory accuracy (0.05% + 0.3°C) in
a rugged handheld test tool.
Large backlit dual display shows any
combination of T
1
, T
2
(52 and 54 only),
T
1
-T
2
(52 and 54 only) plus MIN, MAX,
or AVG
Relative time clock on MIN, MAX, and
AVG provides a time reference for major
events
Electronic Offset function allows
compensation of thermocouple errors to
maximize overall accuracy
Readout in °C, °F, or Kelvin (K)
Sleep mode increases battery life
Battery door allows easy battery
replacement without breaking the
calibration seal
Fluke 51 II
Fluke 52 II
Fluke 53 II
Fluke 54 II