Pressure module specifications (all specifications in % of full span. Specifications reflect a confidence interval of 95%.) Model Range/ Resolution Reference Range (approx)/ uncertainty Stability Temperature Total 1 Resolution (23 ± 3ºC) (1 year) (0 to 50ºC) uncertainty Differential FLUKE-700P00 FLUKE-700P01 FLUKE-700P02 FLUKE-700P22 FLUKE-700P03 FLUKE-700P23 FLUKE-700P04 FLUKE-700P24 1 in. H2O/0.001 10 in. H2O/0.01 1 psi/0.0001 1 psi/0.0001 5 psi/0.0001 5 psi/0.0001 15 psi/0.001 15 psi/0.001 0.25 kPa/0.0002 2.5 kPa/0.002 6900 Pa/0.7 6900 Pa/0.7 34 kPa/0.001 34 kPa/0.001 103 kPa/0.01 103 kPa/0.01 0.300 0.200 0.150 0.100 0.050 0.025 0.025 0.025 0.025 0.050 0.070 0.020 0.020 0.010 0.010 0.010 0.025 0.050 0.080 0.030 0.030 0.015 0.015 0.015 0.350 0.300 0.300 0.150 0.100 0.050 0.050 0.050 Gage FLUKE-700P05 FLUKE-700P06 FLUKE-700P27 FLUKE-700P07 FLUKE-700P08 FLUKE-700P09 30 psi/0.001 100 psi/0.01 300 psi / 0.01 500 psi/0.01 1000 psi/0.1 1500 psi/0.1 207 kPa/0.01 690 kPa/0.07 2070 kPa / 0.1 3400 kPa/0.1 6900 kPa/0.7 10 MPa/0.001 0.025 0.025 0.025 0.025 0.025 0.025 0.010 0.010 0.010 0.010 0.010 0.010 0.015 0.015 0.015 0.015 0.015 0.015 0.050 0.050 0.050 0.050 0.050 0.050 Absolute (not compatible with Fluke 701 or 702) FLUKE-700PA3 FLUKE-700PA4 FLUKE-700PA5 FLUKE-700PA6 5 psi/0.0001 15 psi/0.001 30 psi/0.001 100 psi/0.01 34 kPa/0.001 103 kPa/0.01 207 kPa/0.01 690 kPa/0.07 0.050 0.050 0.050 0.050 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.070 0.070 0.070 0.070 Vacuum (not compatible with Fluke 701 or 702) FLUKE-700PV3 -5 psi/0.0001 FLUKE-700PV4 -15 psi/0.001 -34 kPa/0.001 -103 kPa/0.01 0.040 0.040 0.015 0.015 0.015 0.015 0.070 0.070 Dual FLUKE-700PD2 ±1 psi/0.0001 ±6900 Pa/0.7 FLUKE-700PD3 ±5 psi/0.0001 ±34 kPa/0.001 FLUKE-700PD4 ±15 psi/0.001 ±103 kPa/0.01 FLUKE-700PD5 -15/30 psi/0.001 -100/207 kPa/0.01 FLUKE-700PD6 -15/100 psi/0.01 -100/690 kPa/0.07 FLUKE-700PD7 -15/200 psi/0.01 -100/1380 kPa/0.1 0.150 0.040 0.025 0.025 0.025 0.040 0.025 0.015 0.010 0.010 0.010 0.015 0.025 0.015 0.015 0.015 0.015 0.015 0.200 0.070 0.050 0.050 0.050 0.070 High FLUKE-700P29 FLUKE-700P30 FLUKE-700P31 3000 psi/0.1 5000 psi/0.1 10000 psi/1 20.7 M Pa/0.001 34 M Pa/0.001 69 M Pa/0.007 0.050 0.050 0.050 0.010 0.010 0.010 0.020 0.020 0.020 0.080 0.080 0.080 High 2 Low 2 Max over- side side Fitting pressure media media material (x nominal) Dry Dry 316 SS 30x Dry Dry 316 SS 3x Dry Dry 316 SS 3x 316 SS Dry 316 SS 3x Dry Dry 316 SS 3x 316 SS Dry 316 SS 3x Dry Dry 316 SS 3x 316 SS Dry 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 2x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS Dry 316 SS 3x 316 SS Dry 316 SS 3x 316 SS Dry 316 SS 3x 316 SS Dry 316 SS 3x 316 SS Dry 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x 316 SS N/A 316 SS 3x C276 N/A C276 2x C276 N/A C276 2x C276 N/A C276 1.5x 1 Total uncertainty, one year for temperature range 0°C to +50°C. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C. For P00 module only, compensated temperature range is 15° to 35° C. 2 "Dry" indicates dry air or non-corrosive gas as compatible media. "316 SS" indicates media compatible with Type 316 Stainless Steel. "C276" indicates media compatible with Hastelloy C276. Use of pressure zero is required prior to measurement or source. Maximum overpressure specification includes common mode pressure. Modules are rated. Metric adapter(s): 1/4" NPT female to male BSP/ISO 1/4-19, tapered thread, included with all modules except P29, P30, and P31. Effective October 1996, all modules include a NIST traceable certificate and test data.