Fluke 718EX-300G Fluke 718Ex-300G Intrinsically Safe Pressure Calibrator Datas - Page 2
Specifications - to oz
View all Fluke 718EX-300G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Specifications continued Pressure display (external modules) Operating modes Pressure Module Readout Pressure range Determined by pressure module Resolution 5 digits Accuracy Determined by pressure module Engineering Units (in Hg) PSI, in. H2O (4 °C), in. H2O (20 °C), Kpa, cm H2O (4 °C), cm H2O (20 °C), BAR, mBAR, Kg/cm2, mmHg, in Hg Current specifications 18 °C to 28 °C, one year Current Measurement Range 0 mA to 24 mA Resolution .001 mA mA ± 5 °C .02 % Rdg ± 2 count Temp Coeff. to 18 °C, to 55 °C ± .005 % of range per °C Mode Measure pressure (using internal sensor) D isplay pressure module reading (automatically selected when pressure module connected) Measure current Input/output Pressure input Pressure module input Current input 1/8 in. NPT pressure fitting LEMO connector Shrouded banana jacks Battery Power One 9-volt alkaline battery Battery life 4 to 20 hours, depending on functions used Zeroing modes Mode Gage and differential Pushing Zero button stores present pressure value as an offset and subtracts it from the displayed value Absolute Pushing Zero button causes nominal barometric pressure to be displayed. User corrects to actual barometric pressure with up/down keys. Difference is used as zero offset calibration. Pressure module specification (All specifications in % of full span. Specifications reflect a confidence interval of 95 %.) Range/ Model Resolution Range (approx)/ Resolution Differential FLUKE-700P01Ex FLUKE-700P24Ex Gage FLUKE-700P05Ex FLUKE-700P06Ex FLUKE-700P27Ex FLUKE-700P09Ex Absolute FLUKE-700PA4Ex High FLUKE-700P29Ex 10 in. H2O/0.01 15 psi/0.001 30 psi/0.001 100 psi/0.01 300 psi / 0.01 1500 psi/0.1 15 psi/0.001 3000 psi/0.1 2.5 kPa/0.002 103 kPa/0.01 207 kPa/0.01 690 kPa/0.07 2070 kPa / 0.1 10 MPa/0.001 103 kPa/0.01 20.7 M Pa/0.001 Reference uncertainty Stability Temperature Total1 (23 ± 3 ºC) (1 year) (0 to 50 ºC) uncertainty 0.200 0.025 0.025 0.025 0.025 0.025 0.050 0.050 0.050 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.050 0.015 0.015 0.015 0.015 0.015 0.010 0.020 0.300 0.050 0.050 0.050 0.050 0.050 0.070 0.080 High2 side media Dry 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS C276 Low2 Max over- side Fitting pressure media material (x nominal) Dry 316 SS 3x Dry 316 SS 3x N/A 316 SS 3x N/A 316 SS 3x N/A 316 SS 3x N/A 316 SS 2x N/A 316 SS 3x N/A C276 2x 1 Total uncertainty, one year for temperature range 0 °C to +50 °C. Total uncertainty, 1.0 % of full span for temperature range -10 °C to 0 °C. 2 "Dry" indicates dry air or non-corrosive gas as compatible media. "316 SS" indicates media compatible with Type 316 Stainless Steel. "C276" indicates media compatible with Hastelloy C276. Environmental and safety requirements Operating temperature Non-operating temperature R elative humidity (%RH operating without condensation) Size (LxWxD) Weight Vibration Shock EMC -10 °C to 55 °C -40 °C to 71 °C 95 % (10 °C to 30 °C) 75 % (30 °C to 40 °C) 45 % (40 °C to 50 °C) 35 % (50 °C to 55 °C) 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) 35 oz (992 g) Random, 2g, 5-500 Hz 1 Meter Drop test EN61326 2002-02, Criteria C Fluke. Keeping your world up and running.® ©2007-2008 Fluke Corporation. All copyrights are the property of their respective owners. Specifications subject to change without notice. Printed in U.S.A. 5/2008 2116965 D-EN-N Rev E