Fluke 77-IV Fluke 77IV Digital Multimeter Datasheet - Page 1
Fluke 77-IV Manual
View all Fluke 77-IV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Fluke 77IV Series Digital Multimeter Extended specifications Technical Data General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity of 0 % to 90 %. Accuracy specifications take the form of ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any 1000 V terminal and earth ground Surge protection 8 kV peak per IEC 61010 Fuse for mA inputs 440 mA, 1000 V FAST Fuse Fuse for A input 11 A, 1000 V FAST Fuse Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec Frequency: 10,000 counts; Capacitance: 1000 counts Altitude Operating: 2000 m; Storage: 12,000 m Temperature Operating: -10 °C to +50 °C; Storage: -40 °C to +60 °C Temperature coefficient 0.1 X (specified accuracy /°C) (< 18 °C or > 28 °C) Electromagnetic compatibility In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) except in temperature: specified accuracy ± 5 °C, ± 9 °F Relative humidity (maximum non-condensing) 90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C Battery life 400 hours typical (Alkaline) Size (H x W x L) 4.3 cm x 9 cm x 18.5 cm Weight 420 g Safety compliances ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV Certifications CSA, TÜV (EN61010), UL, CE, (N10140), VDE N10140 Function Volts ac Volts dc mV Overload Protection1 1000 V 1000 V 1000 V2 Input Impedance (Nominal) > 10 MW < 100 pF > 10 MW < 100 pF > 10 MW < 100 pF Common Mode Rejection Ratio (1 kW Unbalanced) > 60 dB @ dc, 50 Hz or 60 Hz > 120 dB @ dc, 50 Hz or 60 Hz > 120 dB @ dc, 50 Hz or 60 Hz Open Circuit Test Voltage Full Scale Voltage To: 6.0 MW 50 MW Ohms/ Capacitance Continuity/ Diode test 1000 V2 1000 V2 < 8.0 V dc < 660 mV dc < 4.6 V dc < 8.0 V dc 2.4 V dc 1 107 V-Hz maximum. 2 For circuits < 0.3 A short circuit. 660 V for high energy circuits. Normal Mode Rejection > 60 dB @ 50 Hz or 60 Hz > 60 dB @ 50 Hz or 60 Hz Short Circuit Current < 1.1 mA < 1.1 mA Function mA A Overload Protection Fused, 440 mA, 1000 V FAST Fuse Fused, 11 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest. 20 A overload for 30 seconds maximum, 10 minutes rest. Function AC volts (average responding) DC mV DC volts Continuity Range 6.000 V 60.00 V 600.0 V 1000 V 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 600 W Resolution 0.001 V 0.01 V 0.1 V 1 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1 W Accuracy ± ( [ % of Reading ] + [ Counts ] ) 2.0 % + 2 (45 Hz to 1 kHz) 0.3 % + 1 0.3 % + 1 Meter beeps at 250 W; detects opens or shorts of 250 µs or longer. Ohms 600.0 W 6.000 kW 60.00 kW 600.0 kW 6.000 MW 50.00 MW 0.1 W 0.001 kW 0.01 kW 0.1 kW 0.001 MW 0.01 MW 0.5 % + 2 0.5 % + 1 0.5 % + 1 0.5 % + 1 0.5 % + 1 2.0 % + 1 Diode test Capacitance AC amps2 (average responding) DC amps2 Hz5 (ac voltage input) MIN MAX AVG 2.400 V 0.001 V 1 % + 2 1000 nF 10.00 µF 100.0 µF 9999 µF1 1 nF 0.01 µF 0.1 µF 1 µF 1.2 % + 2 1.2 % + 2 1.2 % + 2 10 % typical 60.00 mA 400.0 mA3 6.000 A 10.00 A4 0.01 mA 0.1 mA 0.001 A 0.01 A 2.5 % + 2 (45 Hz to 1 kHz) 60.00 mA 400.0 mA3 6.000 A 10.00 A4 0.01 mA 0.1 mA 0.001 A 0.01 A 1.5 % + 2 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 % + 1 For dc functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 275 ms in duration. For ac functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 1.2 s in duration. 1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2. 2 Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A. 3 400.0 mA accuracy specified up to 600 mA overload. 4 > 10 A unspecified. 5 Frequency is specified from 2 Hz to 99.99 kHz. Below 2 Hz, the display shows zero Hz. Fluke. Keeping your world up and running.™ ©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 12/2006 2805757 D-EN-N Rev A