Fluke T5-600 Fluke T5-600 and T5-1000 Electrical Tester Datasheet - Page 2
Auto Off, Specifications, Replacement Parts, Accessories - test leads
View all Fluke T5-600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Auto Off 45 min LO M + + 2 AA + + OFF Do not overtighten screw WWarning • Disconnect test leads from power source before opening battery door. • Débranchez les cordons d'essai avant d'ouvrir le couvercle de la pile. • Prima di aprire lo sportello del vano della pila, scollegare i cavetti dal circuito di alimentazione. • Die Prüfleiter vor dem Öffnen des Batteriefachs von der Stromquelle trennen. • Desconecte los conductores de prueba de la fuente de alimentación antes de abrir la cubierta de la batería. • Antes de abrir a tampa do compartimento das pilhas, desconecte os terminais de teste da fonte de alimentação. • Maak de meetkabels los van de stroombron voordat u de batterijklep opent. • Koble prøveledningene fra strømkilden før batteridekselet åpnes. • Søgeledningerne skal tages evt. emne, inden batteridækslet åbnes. • Irrota koestusjohtimet virtalähteestä ennen paristolokeron avaamista. • Koppla bort mätsladdarna från strömkällan innan du öppnar batteriluckan. • • • • • Specifications Specifications subject to change without notice. Calibration 1-year calibration cycle Temperature Operating: Storage: -10 °C to +50 °C (14 °F to 122 °F) -30 °C to +60 °C (-22 °F to +140 °F) Altitude Operating: Storage: 2000 m (6562 ft) 10,000 m (32808 ft) Relative Humidity 0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F); 0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F); 0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F) Battery Type and Life AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V / m Enclosure Rating IP 52 per IEC 60529, no vacuum applied Safety Complies with ANSI/ISA-S82.01-94, UL classified to IEC 61010, CSA/CAN C22.2 No.1010.1-92, and EN 610101: 1995. EMC EN 61326 Temperature coefficient Accuracy 0.1 x (specified accuracy) / °C for 28 °C (< 64.4 °F or > 82.4 °F) ± ( [ % of reading] + [number of least significant digits] ) Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are accoupled, average responding, and calibrated to the rms value of a sine wave input. CAT III protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings. CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service. Function T5-600 Range K 600 V rms L 600 V T5-1000 Range 1000 V rms 1000 V Resolution Accuracy 1 V ± (1.5 % + 2 digits) 1 V ± (1 % + 1 digit) ? 100.0 A 100.0 A 0.1 A ± (3 % + 3 digits) 1000 V CAT III 600 V CAT IV e 1000 Ω 1000 Ω 1 Ω ± (1 % + 2 digits) P Certifications: $ In accordance with IEC 61010-1, 54CJ Replacement Parts Test Lead Assembly. Replace only with Fluke double-insulated T leads ( ) See "Accessories" for available probes. Battery Door Battery Door Screw PN 648029 PN 1626588 PN 1618578 Accessories H5 Belt Holster TP1 Probe Set, Flat-Blade AC285 SureGrip™ Alligator Clips AC220 SureGrip™ Alligator Clips Service Information Sheet, PN 686953 To contact Fluke, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Visit Fluke's Web site at www.fluke.com.