Page 2 highlights

PRE-INSTALLATION REQUIREMENTS Tools Required for Installation: 1. Phillips screwdriver 2. 10 mm socket with ratchet. 3. Channel-lock adjustable pliers. 4. Carpenter's level. ELECTRICAL REQUIREMENTS CIRCUIT - Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. NOTE: Because of potential inconsistent voltage capabilities, the use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended. OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to be located so the power supply cord is absence of local codes, with the National Electrical Codes, ANSI/NFPA 70 (latest edition). If in doubt, call a licensed electrician. DO NOT cut off or alter the grounding prong on the power supply cord. In situations where a two-slot receptacle is present, it is the owner's responsibility to have a licensed electrician replace it with a properly grounded three prong grounding type receptacle. WATER SUPPLY REQUIREMENTS Hot and cold water faucets MUST be installed within 42 inches (107 cm) of your washer's water inlet. The faucets MUST be 3/4 inch (1.9 cm) garden hose type so inlet hoses can be connected. Water pressure MUST be between 30 and 120 pounds per square inch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your water department can advise you of your water pressure. DRAIN REQUIREMENTS 1. Drain capable of eliminating 17 gals (64.3 L) per minute. 2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum. 3. The standpipe height above the floor should be: Minimum height: 24 in. (61 cm) Maximum height: 96 in. (244 cm) accessible when the washer is in an installed position. NOTE: GFI (Ground Fault Interrupter) receptacle is not required. GROUNDING REQUIREMENTS Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded. 1. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. 2. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the 96 in. (244 cm) Max. 24 in. (61 cm) Min. BACK NOTE: Drain hose attached to the washer can reach a 79 in. (201 cm) high standpipe. For higher standpipe, use hose P/N 134889610, available from an authorized parts distributor. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

2
PRE-INSTALLATION REQUIREMENTS
Tools Required for Installation:
1.
Phillips screwdriver
2.
10 mm socket with ratchet.
3.
Channel-lock adjustable pliers.
4.
Carpenter’s level.
ELECTRICAL REQUIREMENTS
CIRCUIT
- Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY
- 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
NOTE:
Because of
potential inconsistent voltage capabilities, the use of this
washer with power created by gas powered generators,
solar powered generators, wind powered generators or
any other generator other than the local utility company
is not recommended.
OUTLET RECEPTACLE
- Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
NOTE:
GFI (Ground Fault Interrupter) receptacle is not
required.
GROUNDING REQUIREMENTS
Improper connection of the equipment
grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.
1.
The washer
MUST
be grounded. In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
2.
Since your washer is equipped with a power supply
cord having an equipment-grounding conductor
and a grounding plug, the plug
MUST
be plugged
into an appropriate, copper wired receptacle that
is properly installed and grounded in accordance
with all local codes and ordinances or in the
24 in.
(61 cm)
Min.
96 in.
(244 cm)
Max.
BACK
absence of local codes, with the National Electrical
Codes, ANSI/NFPA 70 (latest edition). If in doubt,
call a licensed electrician.
DO NOT
cut off or alter
the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,
it is the owner’s responsibility to have a licensed
electrician replace it with a
properly grounded
three prong grounding type receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets
MUST
be installed within
42 inches (107 cm) of your washer’s water inlet. The
faucets
MUST
be 3/4 inch (1.9 cm) garden hose type
so inlet hoses can be connected. Water pressure
MUST
be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure.
DRAIN REQUIREMENTS
1.
Drain capable of eliminating 17 gals (64.3 L) per
minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3.
The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244 cm)
NOTE:
Drain hose attached to the washer can reach a
79
in. (2
01
cm) high standpipe. For higher standpipe,
use hose P/N
134
8896
10
, available from an
authorized parts distributor.