24" ELECTRIC RANGE INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Clearances and Dimensions 1. Provide adequate clearances between the range and adjacent combustible surfaces. 2. Location-Check location where the range will be installed. Check for proper electrical supply, and the stability of the floor. 3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level. FRONT VIEW SIDE VIEW Minimum to wall on either side range above 36'' (914 mm) of 1" (2.5 cm) height. 24" 30" (61 cm) (76 cm) Minimum Minimum to 18" cabinets on (46 cm) either side of range. 36" (92 cm) 13" 33 cm Maximum depth for cabinets above range top. 25" 64 cm Refer to your serial plate for applicable agency certifications 24" (61 cm) 0" (0 mm) clearance below cooking top and at rear of range. All dimensions for electrical outlet location are maximum. Shaded area shows where the electrical outlet must be installed for flush to the wall installation. 24" (61 cm) 35" 89 cm 23.5" 60 cm 23-5/8" 60 cm 41.5" 105 cm Maximum door open 3-3/4" (9.5 cm) 10" (25 cm) Wall Edge *30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" (0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS. TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF THE CABINETS. 1 P/N 809019202 REV A (2018/11) English - Pages 1-7 Español - Páginas 5-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

1
24" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
P/N
809019202 REV A (2018/11)
Clearances and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location—Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE
BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT
LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR
THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE,
POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE
LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN
BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE
BOTTOM OF THE CABINETS.
English - Pages 1-7
Español - Páginas 5-8
35”
89 cm
23.5”
60 cm
35”
89 cm
23-5/8”
60 cm
41.5”
105 cm
Maximum
door open
All dimensions for electrical outlet location
are maximum.
Shaded area
shows where the electrical outlet must be
installed
for flush to the wall installation.
Wall
Edge
3-3/4” (9.5 cm)
10”
(25 cm)
24”
(61 cm)
FRONT
VIEW
Minimum to wall
on either side of
range above
36’’ (914 mm)
height.
SIDE
VIEW
1”
(2.5 cm)
36”
(92 cm)
24”
(61 cm)
18”
(46 cm)
Minimum to
cabinets on
either side of
range.
13”
33 cm
Maximum depth
for cabinets
above range top.
0” (0 mm) clearance below cooking top and at rear of range.
24”
(61 cm)
25”
64 cm
30”
(76 cm)
Minimum
Refer to your serial plate for applicable
agency certifications