Frigidaire FCRE3062AB Installation Instructions - Page 6

Wire Power Cord Connection, Existing installations ONLY, Wire Power Cord Connection

Page 6 highlights

30" ELECTRIC REAR CONTROL FREESTANDING INSTALLATION INSTRUCTIONS 4-Wire Power Cord Connection (New branch-circuit or mobile home) 1. Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely to the terminal block. IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these nuts are loosened or removed. 2. You must disconnect the ground strap. Remove the factory installed ground screw and plate to release the copper ground strap from the frame of the appliance. Cut and discard the copper ground strap and plate. Keep the ground screw. 3. Connect the GREEN ground wire lead with the eyelet to the frame of the appliance with the ground screw using the same hole in the frame where the ground screw was originally installed. 4. Follow the manufacturer's installation instructions supplied with the strain relief and install. 5. Make sure all screws are tightened securely and replace the rear access cover. 3-Wire Power Cord Connection (Existing installations ONLY) A ground strap is installed on this range which connects the center terminal of the terminal block (Neutral) to the range chassis. The ground strap is connected to the range by the center screw (see Fig. 15). The ground strap must not be removed unless National, State or Local Codes do not permit use of a ground strap. NOTE: If the ground strap is removed for any reason, a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source. 1. Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely to the terminal block. IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed. 2. Follow the manufacturer's installation instructions supplied with the strain relief and install. 3. Make sure all connections are tightened securely and replace the rear access cover. 4 BLACK GREEN Remove ground strap WHITE L1 NEUTRAL 3 BLACK Ground strap Ground screw and plate WHITE L1 NEUTRAL RED L2 Fig. 14 NOTE: Internal white wire not present on all models. RED L2 Fig. 15 NOTE: Internal white wire not present on all models. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

6
30” ELECTRIC REAR CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
3-Wire Power Cord Connection
(Existing installations ONLY)
A ground strap is installed on this range which connects
the center terminal of the terminal block (Neutral) to the
range chassis. The ground strap is connected to the range
by the center screw (see Fig. 15). The ground strap must
not be removed unless National, State or Local Codes do
not permit use of a ground strap.
NOTE:
If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
1.
Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block.
IMPORTANT NOTE:
DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these 3 nuts are
loosened or removed.
2.
Follow the manufacturer’s installation instructions
supplied with the strain relief and install.
3.
Make sure all connections are tightened securely and
replace the rear access cover.
Fig. 15
Fig. 14
NOTE: Internal white wire not present on all models.
4-Wire Power Cord Connection
(New branch-circuit or mobile home)
1.
Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block.
IMPORTANT NOTE: DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these nuts are
loosened or removed.
2.
You must disconnect the ground strap.
Remove the
factory installed ground screw and plate to release the
copper ground strap from the frame of the appliance.
Cut and discard the copper ground strap and plate.
Keep the ground screw.
3.
Connect the GREEN ground wire lead with the eyelet
to the frame of the appliance with the ground screw
using the same hole in the frame where the ground
screw was originally installed.
4.
Follow the manufacturer’s installation instructions
supplied with the strain relief and install.
5.
Make sure all screws are tightened securely and
replace the rear access cover.
4
BLACK
L1
RED
WHITE
NEUTRAL
GREEN
L2
Remove ground strap
3
BLACK
L1
RED
WHITE
NEUTRAL
L2
Ground screw
and plate
Ground
strap
NOTE: Internal white wire not present on all models.