Carefully Slide Range Into Final Location.

Page 5 highlights

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS (For 3 or 4 Wire, 60 Hz. Systems) 4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS. 3 - Wire Permanent Connection - follow Steps 1,2 & 5 below. 4 - Wire Permanent Connection - follow Steps 1 thru 5 below. Before wiring the range, review the suggested power source location drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-circuit or mobile home requires 4-Wire connection): 1. (3 & 4 - Wire Permanent Connections) Follow the manufacturer's installation instructions supplied with the strain relief and install. 2. (3 & 4 - Wire Permanent Connections) Strip insulation away from the ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal block (Follow wire locations shown in Fig. 14). IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed. NOTE: For 3-Wire Permanent Connections skip Steps 3 & 4 and continue with Step 5. 3. (4-Wire Permanent Connection ONLY) Disconnect the ground strap. Remove the factory installed ground screw & plate to release the factory installed copper ground strap from frame of the appliance. Cut and discard the copper strap from the terminal block. KEEP the ground screw, ground plate and go to Step 4. 4. (4-Wire Permanent Connection ONLY) Connect the ground wire lead (Green) to the frame of the appliance using the ground screw & plate as shown in Fig. 15. Be sure to install using the same hole in the frame where the ground screw was originally installed. 5. (3 & 4 - Wire Permanent Connections) Make sure all connections are tightened securely and replace the rear access cover (See Fig. 9). Fig. 14 NOTE: Non-terminated field wire compression connections must be set at approximately 90in./lbs. 5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION. Be sure to provide all the adequate clearances and dimensions shown in Figs. 1, 2 & 3 on Page 1 before moving range into final location. Fig. 15 Carefully slide range into final position while inserting rear leveling leg into and FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7). Make sure the power cord folds into the remaining open floor area behind the range Warmer or storage drawer. Be sure to check the level of the range. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 3 or 4 Wire, 60 Hz. Systems)
5
NOTE:
Non-terminated field wire compression connections
must be set at approximately 90in./lbs.
4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.
3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.
Before wiring the range, review the suggested power source
location drawings in Fig. 3. If connecting to a 4-Wire electrical
system (new branch-circuit or mobile home requires 4-Wire
connection):
1.
(3 & 4 - Wire Permanent Connections)
Follow the
manufacturer’s installation instructions supplied with the
strain relief and install.
2.
(3 & 4 - Wire Permanent Connections)
Strip insulation
away from the ends of the permanent wiring for Line 1, Line
2, Neutral (also strip ground wire on 4-Wire Connections).
Tighten all 3 wire leads to the terminal block (Follow wire
locations shown in Fig. 14).
IMPORTANT NOTE:
DO NOT LOOSEN the factory
installed nut connections which secure the range wiring to
the terminal block. Electrical failure or loss of electrical
connection may occur if these 3 nuts are loosened or
removed.
NOTE: For 3-Wire Permanent Connections
skip Steps 3 & 4 and continue with Step 5.
3.
(4-Wire Permanent Connection ONLY)
Disconnect the
ground strap.
Remove the factory installed ground screw &
plate to release the factory installed copper ground strap
from frame of the appliance. Cut and discard the copper
strap from the terminal block. KEEP the ground screw,
ground plate and go to Step 4.
4.
(4-Wire Permanent Connection ONLY)
Connect the
ground wire lead (Green) to the frame of the appliance
using the ground screw & plate as shown in Fig. 15. Be sure
to install using the same hole in the frame where the ground
screw was originally installed.
5.
(3 & 4 - Wire Permanent Connections)
Make sure all
connections are tightened securely and replace the rear
access cover (See Fig. 9).
Fig. 14
Fig. 15
5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.
Be sure to provide all the adequate clearances and dimensions
shown in Figs. 1, 2 & 3 on Page 1 before moving range into
final location.
Carefully slide range into final position while inserting rear
leveling leg into and FULLY ENGAGING THE ANTI-TIP
BRACKET (See Fig. 7). Make sure the power cord folds into
the remaining open floor area behind the range Warmer or
storage drawer. Be sure to check the level of the range.