24" Built-In Dishwasher w/Ready-Select Slim Controls (RSFDFISSCHCDW)24Aw1S3H/UPESRl/aWs/tBic Tub (PT) Baseline 24" BUILT-IN Front 24" Left 25" Right 49 1/4" 22 1/2" 33 1/2" Adjustable to 35" Door in 90° open position 16 3/8" 3 3/4" Water inlet valve Power supply location 17 3/4" (right bottom front) To junction box 90° 341/4" min. 24" min. 90° Electrical, water, and drain lines must be confined to shaded area 18" 4" 7 3/4" 3" Hot Electrical water wiring 6" line 6" 2 1/2" 2 1/2" 24" INSTALLATION SPECIFICATIONS • Product Shipping Weight (approx.) - 83 Lbs. • Voltage Rating - 120V / 60 Hz / 15 Amps (maximum 20 Amps if connected with disposer) • Connected Load (kW Rating) @ 120 Volts = 1.44 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120V = 10 Amps • Always consult local and national electric & plumbing codes. Meets requirements of ASSE 1006 - integral air gap on supply. • Water Pressure - Hot water line to dishwasher must provide between 20 and 120 pounds per square inch (psi) with at least 120° F hot water temperature. • Make sure location has correct drain, water and electrical outlets to make connections - MUST be confined to shaded areas. • Electrical and water supplies should enter cabinet opening on floor, or through back or side walls, as shown in shaded areas. • Keep back free of drain, water & electrical supply. • Connections preferably located toward left side of dishwasher. Do not cross drain, water or electrical lines in front of motor, blower or frame. • If connecting drain hose to sink trap, local code may require installation of Air Gap Kit (not included). • Leveling legs supplied to adjust height. (Note: Height only adjustable to 35-3/4" max. when installed in 35-3/4" max. standard cabinetry cutout. 5/16" min. clearance required from top of unit to underside of countertop. Dimensions do NOT include insulation - insulation blanket may be compressed during installation.) • When installing adjacent to wall, cabinet or other obstruction that extends beyond front edge of unit, allow 2" minimum clearance between opened door and obstruction. • Floor should be flat and free of obstructions with carpet removed to provide motor clearance. • When installing at end of cabinet line, sides and back must be fully enclosed. • Do not install unit under a cooktop, damage will occur. • Recommended to seal cabinets, enclosing all sides of dishwasher, including underside of countertop, with oil-based paint or moisture-proof polyurethane to prevent possible steam/moisture damage. Meets requirements of ASSE 1006 Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca. Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FFCD2413U 06/18 © 2018 Electrolux Home Products, Inc.

  • 1
  • 2
  • 3

INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 83 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
(maximum 20 Amps if connected
with disposer)
Connected Load (kW Rating) @ 120 Volts = 1.44 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire service
with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120V = 10 Amps
Always consult local and national electric & plumbing codes. Meets
requirements of ASSE 1006 — integral air gap on supply.
Water Pressure – Hot water line to dishwasher must provide between 20 and
120 pounds per square inch (psi) with at least 120° F hot water temperature.
Make sure location has correct drain, water and electrical outlets to make
connections — MUST be confined to shaded areas.
Electrical and water supplies should enter cabinet opening on floor, or through
back or side walls, as shown in shaded areas.
Keep back free of drain, water & electrical supply.
Connections preferably located toward left side of dishwasher. Do not cross
drain, water or electrical lines in front of motor, blower or frame.
If connecting drain hose to sink trap, local code may require installation of
Air Gap Kit (not included).
Leveling legs supplied to adjust height.
(Note: Height only adjustable to
35-3/4" max. when installed in 35-3/4" max. standard cabinetry cutout.
5/16" min. clearance required from top of unit to underside of countertop.
Dimensions do NOT include insulation — insulation blanket may be
compressed during installation.)
When installing adjacent to wall, cabinet or other obstruction that extends
beyond front edge of unit, allow 2" minimum clearance between opened door
and obstruction.
Floor should be flat and free of obstructions with carpet removed to provide
motor clearance.
When installing at end of cabinet line, sides and back must be fully enclosed.
Do not install unit under a cooktop, damage will occur.
Recommended to seal cabinets, enclosing all sides of dishwasher, including
underside of countertop, with oil-based paint or moisture-proof polyurethane
to prevent possible steam/moisture damage.
Specifications subject to change.
Accessories information available on the web at
frigidaire.com / frigidaire.ca
Note:
For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FFCD2413U 06/18
© 2018 Electrolux Home Products, Inc.
Power supply location
(right bottom front)
24"
Front
33
1
/
2
"
Adjustable
to 35"
Water inlet valve
49
1
/
4
"
22
1
/
2
"
Right
Left
25"
16
3
/
8
"
3
3
/
4
"
Door in 90°
open position
6"
2
1
/
2
"
2
1
/
2
"
4"
18"
24"
min.
Electrical, water,
and drain
lines
must be confined
to shaded
area
6"
24"
7
3
/
4
"
90°
90°
3"
34
1
/
4
"
min.
Hot
water
line
Electrical
wiring
17
3
/
4
"
To junction box
Meets
requirements of
ASSE 1006
FFCD2413U S/W/B
DISHWASHER
24" BUILT-IN