Frigidaire FFEC3005LS Installation Instructions (All Languages) - Page 4
U.S.A. Only - installation instructions
UPC - 057112990156
View all Frigidaire FFEC3005LS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS This appliance is equipped with a copper conductor flexible cable. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. This appliance is manufactured with a frame connected green (or bare copper) ground wire. 1. If connecting to a 3-wire supply cable (U.S.A. only): If local codes permit connection of the frame grounding conductor to the neutral (white) wire: (The 3-conductor cord or cable must be replaced with a 4-conductor cord or cable where grounding through the neutral conductor is prohibited in new installations, mobile homes, recreational vehicles or in other areas where local codes do not permit neutral grounding) Connect the green (or bare copper) wire (and the white wire for model with warmer zone) from the appliance cable to the supply cable ground wire (white or bare) inside the junction box. Connect the remaining wires inside the junction box (see Figure 4 or 5) from the power supply cable to the matching colors of the appliance cable wires. Cable from Power Supply Ground Wire Red Wires Black Wires Junction Box Ground Wire (Bare or Green Wire) U.L.-Listed Conduit Cable from appliance Connector (or CSA listed) Figure 4 - U.S.A. Only 3-WIRE GROUNDED JUNCTION BOX Cable from Power Supply Ground Wire Red Wires Black Wires Junction Box White Wire Ground Wire (Bare or Green Wire) U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 5 - U.S.A. Only Models 36" with Warmer Zone Only 3-WIRE GROUNDED JUNCTION BOX WARNING Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Use only connectors designed for joining copper to aluminum, and follow the manufacturer's recommended procedure closely. 2. If connecting to a 4-wire supply cable (also mobile homes): The appliance frame must not be connected to the neutral wire of the 4-wire electrical system. Connect the appliance white wire (if a 4-wire appliance cable is supplied) to the power supply cable white wire. Cap the white wire from the power supply cable if a 3-wire appliance cable is supplied. Connect the remaining wires from the supply cable to the matching color wires from the appliance cable (see Figure 6 or 7). The green (or bare copper) wire must now be used to ground the appliance in accordance with local electrical codes. The green (or bare copper) wire from the power supply cable is grounded inside the house service panel. Cable from Power Supply Ground Wire Red Wires White Wire Black Wires Junction Box Ground Wire (Bare or Green Wire) U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 6 - 4-WIRE GROUNDED JUNCTION BOX Cable from Power Supply Ground Wire Red Wires White Wire Ground Wire (Bare or Green Wire) Black Wires Junction Box White Wire U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 7 - 4-WIRE GROUNDED JUNCTION BOX Models 36" with Warmer Zone Only WARNING DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power. 4