Frigidaire FFGC3613LW Installation Instructions (All Languages) - Page 5

Typical Gas Cooktop Installation Over, an Electric Built-in Oven Installed Under the Counter

Page 5 highlights

GAS COOKTOP INSTALLATION INSTRUCTIONS Typical Gas Cooktop Installation Over an Electric Built-in Oven Installed Under the Counter GAS COOKTOP Manifold Pipe Flexible Connector Cabinet sides or filler panel Wall Oven Cabinet 18" (45.7 cm) Max. 6½" 5" (16.5 cm) Flare (12.7 cm) Min. Union Flare Union 4" (10.2 cm) 120V/60Hz Grounded Outlet Pressure Regulator Right Side of Cabinet Manual Shutoff Valve (To be accessible for shut-off valve operation) 1. Wall Outlet Location NOTE: If an outlet is not available, have one installed by a qualified technician. 12" (30.5 cm) 8" (20.3 cm) 10" (25.4 cm) Recommended area for 120V grounded outlet on rear wall 22" (55.9 cm) CL of unit 3. Clamp Down Information Once the cooktop is installed in the counter opening, you must clamp the unit down as shown. To clamp down, insert the bracket with the offset side of the angle into the slots on each side of the unit. The thumb screw should then be run through the bracket, up against the bottom of the counter. Tighten until the unit draws down. Cooktop Countertop Angle Bracket Thumb Screw CL of unit 2. Installation Figure 3 Insert the cooktop into the countertop opening. Note: After inserting the cooktop into the countertop opening, make sure the unit is sitting on the metal flange around the top of the burner box. Cooktop must not sit on the porcelain top. Avoid cutting an oversized hole in the countertop. 5 Figure 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

GAS COOKTOP INSTALLATION INSTRUCTIONS
5
Wall Oven Cabinet
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
GAS COOKTOP
18” (45.7 cm) Max.
5”
(12.7 cm)
Flare
Union
4” (10.2 cm)
120V/60Hz
Grounded
Outlet
Right Side
of Cabinet
Pressure
Regulator
Flare
Union
Flexible Connector
Cabinet sides or
filler panel
6½”
(16.5 cm)
Min.
Manifold Pipe
Manual Shutoff Valve
(To be accessible for shut-off
valve operation)
Figure 3
12" (30.5 cm)
8"
(20.3 cm)
10"
(25.4 cm)
22"
(55.9 cm)
CL
of unit
Recommended
area for 120V
grounded outlet
on rear wall
CL
of unit
NOTE:
If an outlet
is not available,
have one installed
by a qualified
technician.
1. Wall Outlet
Location
2. Installation
Insert the cooktop into the countertop opening.
Note: After inserting the cooktop into the
countertop opening, make sure the unit is sitting
on the metal flange around the top of the burner
box. Cooktop must not sit on the porcelain top.
Avoid cutting an oversized hole in the countertop.
3. Clamp Down Information
Once the cooktop is installed in the counter opening,
you must clamp the unit down as shown.
To clamp down, insert the bracket with the offset side
of the angle into the slots on each side of the unit. The
thumb screw should then be run through the bracket, up
against the bottom of the counter. Tighten until the unit
draws down.
Cooktop
Countertop
Angle Bracket
Thumb Screw
Figure 4