Frigidaire FFHD2250TS Complete Owner s Guide - Page 37

Concern, Potential Cause, Common Solution, Automatic Ice Maker Cont'd

Page 37 highlights

BEFORE YOU CALL Concern Potential Cause Automatic Ice Maker (Cont'd) Common Solution Ice maker is not making enough ice. • Ice maker is producing less ice than you expect. • The ice maker will produce approximately 2.3 pounds of ice (fresh food ice maker) and 2.5 pounds of ice (freezer ice maker) every 24 hours depending on usage conditions. • The water filter may be clogged with foreign material. • If water dispenses slower than normal, or if the filter is six months old or older, it should be replaced. • The water supply line is kinked. • Ensure that the supply line does not kink when the refrigerator is pushed into place against the wall. • Saddle valve on cold water pipe is clogged or restricted by foreign material. • Turn off household water line valve. Remove valve. Clean valve. Replace valve if necessary. • Heavy traffic, opening or closing of the doors excessively. • Freezer control is set too warm (freezer ice maker). • Press Fast Freeze to temporarily increase ice production rate. (Freezer ice maker only.) • Set freezer control to colder setting to improve performance of the ice maker (freezer ice maker). Allow 24 hours for temperature to stabilize. • Water pressure is extremely low. Cut-off and cut-on pressures are too low (well systems only). • Reverse osmosis system is in regenerative phase. • Have someone turn up the cut-off and cut-on pressure on the water pump system (well systems only). • It is normal for a reverse osmosis system to be below 20 psi during the regenerative phase. Freezer ice maker will not stop making ice (select models). • Ice maker wire signal arm is being held down by a package in the freezer that has fallen against ice maker. • Move any item or frozen ice cubes that may block the signal arm from being in the off or upward position. See Automatic Ice Maker-Freezer section in manual. Ice cubes are freezing together. • Ice cubes are not being used frequently enough or interruption of power for prolonged time. • Remove ice container and discard ice. The ice maker will produce fresh supply. Ice should be used at least twice weekly to keep the cubes separated. • Ice cubes are hollow (shells of ice with water inside). The hollow cubes break open in the bin and leak their water onto existing ice, which causes it to freeze together. • This generally occurs when the ice maker does not get enough water. This is usually the result of a clogged water filter or restricted water supply. Replace the water filter and if the condition still occurs check for a clogged Saddle Valve, water valve not turned on all the way or kinked water supply line. 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

37
BEFORE YOU CALL
Concern
Potential Cause
Common Solution
Automatic Ice Maker (Cont’d)
Ice maker is
not making
enough ice.
• Ice maker is producing less
ice than you expect.
The water filter may be
clogged with foreign
material.
• The water supply line is
kinked.
• Saddle valve on cold water
pipe is clogged or restricted
by foreign material.
Heavy traffic, opening
or closing of the doors
excessively.
• Freezer control is set too
warm (freezer ice maker).
• Water pressure is extremely
low. Cut-off and cut-on
pressures are too low (well
systems only).
• Reverse osmosis system is in
regenerative phase.
• The ice maker will produce approximately
2.3 pounds of ice (fresh food ice maker)
and 2.5 pounds of ice (freezer ice maker)
every 24 hours depending on usage
conditions.
• If water dispenses slower than normal,
or if the filter is six months old or older, it
should be replaced.
• Ensure that the supply line does not kink
when the refrigerator is pushed into place
against the wall.
• Turn off household water line valve.
Remove valve. Clean valve. Replace valve
if necessary.
• Press Fast Freeze to temporarily increase
ice production rate. (Freezer ice maker
only.)
• Set freezer control to colder setting to
improve performance of the ice maker
(freezer ice maker). Allow 24 hours for
temperature to stabilize.
• Have someone turn up the cut-off and
cut-on pressure on the water pump
system (well systems only).
• It is normal for a reverse osmosis
system to be below 20 psi during the
regenerative phase.
Freezer ice
maker will
not stop
making
ice (select
models).
• Ice maker wire signal arm
is being held down by a
package in the freezer that
has fallen against ice maker.
• Move any item or frozen ice cubes that
may block the signal arm from being in
the off or upward position. See Automatic
Ice Maker-Freezer section in manual.
Ice cubes
are freezing
together.
• Ice cubes are not being
used frequently enough or
interruption of power for
prolonged time.
• Ice cubes are hollow (shells
of ice with water inside). The
hollow cubes break open in
the bin and leak their water
onto existing ice, which
causes it to freeze together.
• Remove ice container and discard ice. The
ice maker will produce fresh supply. Ice
should be used at least twice weekly to
keep the cubes separated.
• This generally occurs when the ice maker
does not get enough water. This is usually
the result of a clogged water filter or
restricted water supply. Replace the water
filter and if the condition still occurs check
for a clogged Saddle Valve, water valve
not turned on all the way or kinked water
supply line.