Outdoor unit installation

Page 13 highlights

Outdoor unit installation 1. Install the outdoor part of the unit on a flat surface to avoid excess noise and vibration. A condenser pad is recommended. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5. Be sure there is no obstacle which blocks exhausting air, including schrubs or bushes. Strong wind Settlement of outdoor unit. Anchor the outdoor unit tightly and horizontally on a concrete or flat mount with a bolt and nut 2/5" or 5/16" diameter (Purchased separately). Air inlet Air inlet Air outlet Capacity (BTU/h) 9000 12000 18000 22000 28000 33600 26000 34400 Outdoor unit dimension inch(WxHxD) 33-9/25 x 21-6/25 x 12-3/5 33-9/25 x 23-6/25 x 12-3/5 37-3/5 x 27-3/5 x 15-3/5 38-3/5 x 31-1/10 x 16-3/5 38-3/5 x 31-1/10 x 16-3/5 38-3/5 x 31-1/10 x 16-3/5 38-3/5 x 31-1/10 x 16-3/5 42-4/5 x 43-4/5 x 17-3/10 A (inch) B (inch) 21-6/25 22-2/25 24-6/25 26-4/25 26-4/25 26-4/25 26-4/25 31-3/25 11-7/25 14-4/25 15-9/25 17-7/25 17-7/25 17-7/25 17-7/25 18-3/25 Outdoor unit installation 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Outdoor unit installation
12
Outdoor unit installation
Strong wind
1. Install the outdoor part of the unit
on a flat surface to avoid excess
noise and vibration. A condenser
pad is recommended.
2. Direct the air vent toward an area
without obstacles.
3. Install the unit at the site where
it is exposed to as little wind as
possible, especially in areas where
it is frequently windy.
4. If the installation site is exposed to
heavy winds, such as in coastal
areas, place the unit along the
widest part of the wall or use
protective plates.
5. Be sure there is no obstacle which
blocks exhausting air, including
schrubs or bushes.
Air inlet
Air
inlet
Air outlet
Settlement of outdoor unit. Anchor the
outdoor unit tightly and horizontally
on a concrete or flat mount with a
bolt and nut 2/5" or 5/16" diameter
(Purchased separately).
A (inch)
B (inch)
Outdoor unit dimension
inch(WxHxD)
33-9/25 x 21-6/25 x 12-3/5
33-9/25 x 23-6/25 x 12-3/5
38-3/5 x 31-1/10 x 16-3/5
38-3/5 x 31-1/10 x 16-3/5
38-3/5 x 31-1/10 x 16-3/5
38-3/5 x 31-1/10 x 16-3/5
42-4/5 x 43-4/5 x 17-3/10
37-3/5 x 27-3/5 x 15-3/5
21-6/25
9000
12000
18000
22000
28000
33600
26000
34400
22-2/25
24-6/25
26-4/25
26-4/25
26-4/25
26-4/25
31-3/25
11-7/25
14-4/25
15-9/25
17-7/25
17-7/25
17-7/25
17-7/25
18-3/25
Capacity (BTU/h)