Frigidaire FFMV1745TS Product Specifications Sheet - Page 3

Microwave Specifications, Ducted Option Specifications, Optional Accessories

Page 3 highlights

Baseline (FFMV1645T_FFMV1745T - 1.7 Cu. Ft.) Microwaves FFMV1745T S / W/ B 30" Over-The-Range Locate 120V/60Hz grounded outlet inside upper cabinet Microwave MUST be mounted to BOTH a top cabinet† AND a wall.* Bottom edge of cabinet MUST be 30" min. from cooking surface 16 1/2" 66" min. from floor to top of microwave Rear Wall 30" min. 30" min. 2" min. 13" max.** Backsplash Cabinet MUST be capable of supporting a total load of 135 lbs. (or 150 lbs.**) Blower plate allows for vertical or horizontal ducting Power cord location 16 13/32" †When installing beneath smooth, flat cabinets, refer to cabinet template for detailed power cord clearance instructions *Can NOT be installed in island or peninsula cabinet arrangements **If cabinet depth (including doors) is deeper than 13", unit MUST be spaced out from rear wall using adequate materials (supporting 150 lbs.) to allow proper top vent air exhaust/intake rear extrusion 15 1/32" 29 7/8" lower extrusion Allow at least 26" clearance for door depth when open Microwave Specifications • Product Shipping Weight (approx.) - 59 Lbs. • Voltage Rating - 120V / 60 Hz / 15 Amps • Connected Load (kW Rating) @ 120 Volts = 1.6 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 13 Amps • Always consult local and national electric codes. • Grounded outlet should be located in cabinet above, with hole in base to route power cord. Carefully follow top template instructions for power cord clearance when installing beneath smooth, flat cabinets. • Microwave's exhaust ventilation system is preset to recirculate air inside with no ducting system required. Exhausting air outside is optional, using either vertical or horizontal ducting system. (Refer to Ducted Option Specifications for outside ventilation.) • For safe and proper installation, microwave MUST be mounted to BOTH a top cabinet AND a wall, and connected to at least one wall stud. Can NOT be installed in island or peninsula cabinet arrangements. • Cabinet bottom MUST be level to insure proper installation. • Cabinet MUST be capable of supporting a total load of 135 lbs. • When installing beneath smooth, flat cabinets, refer to cabinet template for detailed power cord clearance instructions. • If cabinet depth (including doors) is deeper than 13", unit MUST be spaced out from rear wall using adequate materials (supporting 150 lbs.) to allow proper top vent air exhaust/intake. • Filler blocks recommended for installation when cabinet front hangs below recessed bottom shelf. • Minimum distance of 30" required from cooking surface to bottom edge of top cabinet. • Minimum distance of 66" required from floor to top of microwave. • Opening between cabinets MUST be 30" wide and free of obstructions. For openings up to 36" wide, order optional 36" Filler Panel Kit to fill in gap between unit and cabinets. • Allow 26" minimum clearance for 90° door swing. Ducted Option Specifications • For outside ventilation. • Exhaust duct adapter will be needed for outside ventilation, to mate with standard 3-1/4" x 10" rectangular duct. If round duct required, rectangular-to-round transition adapter will be needed with no less than 6" diameter. • For most efficient airflow exhaust, use a straight run or as few elbows as possible with a maximum duct length of 3-1/4" x 10" rectangular or 6" diameter round duct, not to exceed 120 equivalent feet. • For horizontal installation, be sure to allow enough space between wall studs to accommodate exhaust. • Refer to installation instructions on web for detailed duct preparation and converting exhaust vent blower system for exterior exhaust ventilation. Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions. Optional Accessories • 36" Stainless Steel Filler Panel Kit - (PN # MWFILKTSS). • 36" White Filler Panel Kit - (PN # MWFILKTWH). • 36" Black Filler Panel Kit - (PN # MWFILKTBK). • 15" Bump-Out Kit - (PN # 5304508807). • Charcoal Filter - (PN # 5304464577). USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FFMV1745T 03/17 © 2017 Electrolux Home Products, Inc. Accessories information available on the web at frigidaire.com Specifications subject to change.

  • 1
  • 2
  • 3

Accessories information available
on the web at
frigidaire.com
Microwaves
FFMV1745T S / W/ B
30" Over-The-Range
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FFMV1745T 03/17
© 2017 Electrolux Home Products, Inc.
Specifications
subject to change.
Microwave Specifications
Product Shipping Weight (approx.) – 59 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.6 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @ 120 Volts = 13 Amps
Always consult local and national electric codes.
Grounded outlet should be located in cabinet above, with hole in base
to route power cord. Carefully follow top template instructions for
power cord clearance when installing beneath smooth, flat cabinets.
Microwave’s exhaust ventilation system is preset to recirculate air
inside with no ducting system required. Exhausting air outside is
optional, using either vertical or horizontal ducting system.
(Refer to
Ducted Option Specifications for outside ventilation.)
For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall
stud. Can NOT be installed in island or peninsula cabinet arrangements.
Cabinet bottom MUST be level to insure proper installation.
Cabinet MUST be capable of supporting a total load of 135 lbs.
When installing beneath smooth, flat cabinets, refer to cabinet
template for detailed power cord clearance instructions.
If cabinet depth (including doors) is deeper than 13", unit MUST be
spaced out from rear wall using adequate materials (supporting
150 lbs.) to allow proper top vent air exhaust/intake.
Filler blocks recommended for installation when cabinet front hangs
below recessed bottom shelf.
Minimum distance of 30" required from cooking surface to bottom
edge of top cabinet.
Minimum distance of 66" required from floor to top of microwave.
Opening between cabinets MUST be 30" wide and free of obstructions.
For openings up to 36" wide, order optional 36" Filler Panel Kit to fill
in gap between unit and cabinets.
Allow 26" minimum clearance for 90° door swing.
Ducted Option Specifications
For outside ventilation.
Exhaust duct adapter will be needed for outside ventilation, to mate
with standard 3-1/4" x 10" rectangular duct. If round duct required,
rectangular-to-round transition adapter will be needed with no less
than 6" diameter.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible with a maximum duct length of 3-1/4" x 10" rectangular or
6" diameter round duct, not to exceed 120 equivalent feet.
For horizontal installation, be sure to allow enough space between
wall studs to accommodate exhaust.
Refer to installation instructions on web for detailed duct
preparation and converting exhaust vent blower system for exterior
exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
36" Stainless Steel Filler Panel Kit – (PN # MWFILKTSS).
36" White Filler Panel Kit – (PN # MWFILKTWH).
36" Black Filler Panel Kit – (PN # MWFILKTBK).
15" Bump-Out Kit – (PN # 5304508807).
Charcoal Filter – (PN # 5304464577).
†When installing beneath smooth, flat cabinets, refer to cabinet
template for detailed power cord clearance instructions
*Can NOT be installed in island or peninsula cabinet arrangements
**If cabinet depth (including doors) is deeper than 13"
, unit MUST
be spaced out from rear wall using adequate materials (supporting
150 lbs.) to allow proper top vent air exhaust/intake
13"
max.**
2"
min.
Backsplash
Rear Wall
30"
min.
66"
min.
from floor
to top of
microwave
Bottom edge of
cabinet MUST be
30"
min. from
cooking surface
Cabinet MUST
be capable of
supporting a total
load of 135 lbs.
(or 150 lbs.**)
30"
min.
16
1
/
2
"
Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall.*
Locate 120V/60Hz grounded outlet inside upper cabinet
29
7
/
8
"
16
13
/
32
"
15
1
/
32
"
Power cord
location
Allow at least 26" clearance
for door depth when open
lower
extrusion
rear
extrusion
Blower plate allows for vertical
or horizontal ducting