Frigidaire FGBM19WNVD Installation Instructions - Page 11

Installation Overview, Attach The Mounting, Plate To The Wall, Non-vented Ductless

Page 11 highlights

Installation Instructions A RECIRCULATING (Non-Vented Ductless) INSTALLATION OVERVIEW A1. Attach Mounting Plate to Wall A2. Prepare Top Cabinet A3. Check Blower Plate A4. Mount the Microwave Oven A5. Install or change Charcoal Filter IMPORTANT NOTES: • Make sure the screws for the blower motor and blower plate are securely tightened when they are reinstalled. This will help to prevent excessive vibration. • Make sure the motor wiring has been properly routed and secured, and that the wires are not pinched. IRRBNmTNhoEEEOiusTFAAnTRtHORDiEenaEgR:rW ApIWEITlNaNAatPeDIlSLlSaTRTLnFeVOAdmTOEtLpCoELlLaRlEMLotAeYcOEPaTstDeW IeLIMrOvIAthNePNTeTsGOHhtEoIoNER.W rpizoSToDsInTiTAtIitoaRRHNnl UEeTtThxCCheHTaTbTOuIoSsIItOOttomNNSS 4" outlet. 1. Use a level to check that the template is positioned lo3s2ocf..crtDLaatraehhiocgtrwesaiiccholttluaumtnmdhrtdsseaioooc,iIdttfluradeeoneoinnsrlsroywitodltte.ilihamnfldamievntpthef3heasioe.r/erumr1ukMtcp6mapleapay"nnawtlrthiiktrenlieetkotodhtreaalwelidsutanoostfseltogsooeua.rgtcnddualwaeeddtttooi,islbtoeoidtoosnuadrnulsidstlsapsl.t.colp5Wo,rno/nee8hrevwt"tehetshwrehne.oeollFyleteohwofssdtereporfhiaoegrocrhilesetds toggle bolts. DO NOT INSTALL THE MOUNTING PLATE 54A..TRRinTeesHvmtaiIeSollwavTteitIohMtnheEesI.nitteusmtaatpliloalantit.oenfrIonmstrtuhcetiroenabr owoakll.for your DvearrsleióvnueenltaEasplaañhoolj.a para consultar la Locate and mark holes to align with holes in the mounting plate. IMPORTANT: LOCATE AT LEAST ONE STUD ON EITHER SIDE OF MSTHPAAERCKCEETDNHTTEOELRGOLGCINLAEET.IBOONLFTOSRIN2TAHDEDMITOIOUNNATLIN, EGVPELNALTYE AREA. Trim the rear wall template along the dotted line. 3/8" TO EDGE 12" Trim the rear wall template along the dotted line. Locate and mark holes to align with holes in the mounting plate. IMPORTANT: LOCATE AT LEAST ONE STUD ON EITHER SIDE OF MSTHPAAERCKCEETDNHTTEOELRGOLGCINLAEET.IBOONLFTOSRIN2TAHDEDMITOIOUNNATLIN, EGVPELNALTYE AREA. A1. ATTACH THE MOUNTING PLATE TO THE WALL Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud. NOTE: If the cabinet depth including the cabinet doors is more than 13'" ' then the unit must be spaced out from wall using adequate materials supporting 150 Ibs to allow proper top vent air exhaust/intake. 13" MAX. (33 cm) Cabinet Cabinet 1 Remove the toggle wings from the bolts. 2 Insert the bolts into the mounting plate through the holes designated to go into drywall and reattach the toggle wings to 3⁄4″ (19 mm) onto each bolt. To use toggle bolts: Mounting Plate Spacing for Toggles More Than Wall Thickness Toggle Wings Toggle Bolt Wall Bolt End 3 Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate. NOTE: Before tightening toggle bolts and wood screw, make sure the bottom of the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly centered under the cabinet. CAUTION: Be careful to avoid pinching fingers between the back of the mounting plate and the wall. 4 Tighten all bolts. Pull the plate away from the wall to help tighten the bolts. EN-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

INSTALLATION OVERVIEW
Attach Mounting Plate to Wall
Prepare Top Cabinet
Mount the Microwave Oven
IMPORTANT NOTES:
Make sure the screws for the blower motor and blower
plate are securely tightened when they are reinstalled.
This will help to prevent excessive vibration.
Make sure the motor wiring has been properly routed
and secured, and that the wires are not pinched.
Installation Instructions
Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
NOTE:
Before tightening toggle bolts and wood
screw, make sure the bott
m of the mounting plate
touch the bottom of the cabinet when pushed flush
against the wall and that the plate is properly
centered under the cabinet.
CAUTION:
Be careful to avoid pinching fingers
between the back of the mounting plate and the wall.
Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.
4
3
ATTACH THE MOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle bolts.
At least one wood screw must be used to attach
the plate to a wall stud.
Remove the toggle wings from the bolts.
Insert the bolts into the mounting plate through
the holes designated to go into drywall and
reattach the toggle wings to
3
/
4
(19 mm) onto
each bolt.
1
Wall
Mounting
Plate
Spacing for Toggles
More Than Wall
Thickness
Bolt End
Toggle
Bolt
Toggle Wings
To use toggle bolts:
2
RECIRCULATING
(Non-Vented Ductless)
Install or change Charcoal Filter
Check Blower Plate
NOTE:
If the cabinet depth including the cabinet doors
is more than 13
"
'' then the unit must be spaced
o
A
A1.
A2.
A3.
A4.
A5.
A1.
Cabinet
Cabinet
(33 cm)
13" MAX.
out from wall using adequate materials supporting
150 Ibs to allow proper top vent air exhaust/intake.
EN-10