Frigidaire FGC30C3AW Installation Instructions - Page 4

Typical Under Counter Installation of an Electric Built-in, Oven with a Cooktop Mounted Above

Page 4 highlights

GAS COOKTOP INSTALLATION INSTRUCTIONS (For 30" & 36" Models) Typical Under Counter Installation of an Electric Built-in Oven with a Cooktop Mounted Above All mounting hardware must be used to secure the built-in oven to the cabinets. Refer to the built-in oven installation instructions. Junction box must be located approx. 3" to the left of the built-in oven cutout. This cooktop may be installed over certain built-in electric oven models. G Side filler panels are necessary to isolate the unit from adjoining cabinets. Panel height should allow for installation of approved cooktop models. See "Typical Gas Cooktop Installation Over an Electric Built-in Oven Installed Under the Counter" on previous page. 32" Min.** (81.3 cm) 36" (91.4 cm) Min. E 208/240 Volt grounded junction F box for built-in oven. Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. Must be capable of supporting 150 lbs. Cut an opening in wood base minimum 9" (22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from left side filler panel, to route armoured cable to junction box. 4 1/2" (11.4 cm) Max.* * If no cooktop is installed directly over the oven unit, 5" (12.7 cm) maximum is allowed. ** 32" (81.3 cm) min. from top of cabinet to top of runners must be maintained. OVEN SIZE 30" (76.2 cm) 27" (68.6 cm) CUTOUT DIMENSIONS (inches) E Min. Max. 27¼" - 285/8" (69.2 cm) - (72.7 cm) F G Min. Max. 28½" - 29" 23½" (72.4 cm) - (73.7 cm) (59.7 cm) 27¼" - 285/8" 247/8" - 25¼" 23½" (69.2 cm) - (72.7 cm) (63.1 cm) (64.1 cm) (59.7 cm) Figure 3 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" & 36" Models)
4
*
If no cooktop is installed directly
over the oven unit, 5” (12.7 cm)
maximum is allowed.
** 32" (81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
G
F
E
Use 3/4” (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting 150 lbs.
Cut an opening in wood base minimum 9”
(22.9 cm) x 9” (22.9 cm), 2” (5.1 cm) from
left side filler panel, to route armoured
cable to junction box.
4 1/2” (11.4 cm)
Max.*
208/240 Volt grounded junction
box for built-in oven.
All mounting hardware
must be used to secure
the built-in oven to the
cabinets. Refer to the
built-in oven installa-
tion instructions.
Side filler panels are necessary to
isolate the unit from adjoining
cabinets.
Panel height should allow
for installation of approved cooktop
models.
See “Typical Gas Cooktop
Installation Over an Electric Built-in
Oven Installed Under the Counter”
on previous page.
32” Min.**
(81.3 cm)
36”
(91.4 cm)
Min.
CUTOUT DIMENSIONS (inches)
OVEN SIZE
E
F
G
Min.
Max.
Min.
Max.
30"
27¼"
-
28
5
/
8
"
28½"
-
29"
23½"
(76.2 cm)
(69.2 cm)
-
(72.7 cm)
(72.4 cm)
-
(73.7 cm)
(59.7 cm)
27"
27¼"
-
28
5
/
8
"
24
7
/
8
"
-
25¼"
23½"
(68.6 cm)
(69.2 cm)
-
(72.7 cm)
(63.1 cm)
(64.1 cm)
(59.7 cm)
Junction box must
be located approx.
3" to the left of
the built-in oven
cutout.
This cooktop may
be installed over
certain built-in elec-
tric oven models.
Figure 3