30F"GGGFa3s0F4r7eTeFstanding Ranges FrFigRiEdEaSiTrAeNGDaINllGerRyANGE 30" GAS 13" max. 25" Minimum clearance (A) required to nearest combustible wall on either side of range 30"min. 30" min.* 18" min. above 36" height Wall CL 18" min. 30" 111/2" 23" 8" 36" stand. 46 5/8" 15" 101/2" 2" 24" Recommended area for 120V outlet on rear of wall and area for through-the-wall connection of pipe stub and shutoff valve Front Recommended area for through-the-floor connection of pipe stub and shutoff valve * Min. distance from cooking surface to underside of overhead cabinetry Clearance (A) Based on Largest Burner Output Rating on Cooking Surface 9,500 BTU or less 10,000-16,999 BTU 17,000 BTU or greater Minimum Clearance Required 2" 3" 5" 48 1/2" max. 29 7/8" Side 29 1/4" 25 3/4" Gas inlet location (right bottom rear*) Power cord location (left bottom rear*) *when viewed from front Note: Overall product dimensions are model specific and may vary slightly from illustration. Refer to model's product specifications for actual dimensions. 36" (Adjustable to ±1/8") INSTALLATION SPECIFICATIONS • Product Shipping Weight (approx.) - 205 Lbs. • Voltage Rating - 120V / 60 Hz / 5 Amps • Amps @ 120 Volts = 5 Amps • Always consult local and national electric and gas codes. • Make sure wall coverings around range can withstand heat generated by range. • Linoleum or any other synthetic floor covering located beneath range, must be capable of withstanding minimum heat of 90° F above room temperature without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood required between range and a carpeted floor. • Do not obstruct flow of combustion air at oven vent nor around base or beneath lower front panel of range. Range requires fresh air for proper burner combustion. • Do not install range beneath any downward-blowing, overhead vent hood or air curtain. • Range ships with 3/4" factory regulator. • Range is LP Gas convertible. (Optional LP Gas conversion kit available.) • Floor beneath range MUST be solid and level. • Overhead cabinetry should not exceed a 13" maximum depth. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Range can be installed flush to wall with 0" minimum rear clearance. • Minimum clearance required (from edge of rangetop to nearest combustible wall on either side of range above 36" height) is based on largest burner output rating on cooking surface. • To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Follow all dimension requirements provided to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts.. OPTIONAL ACCESSORIES • LP Gas Conversion Kit - (PN # GRLP4). • Griddle - Included Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com. Specifications subject to change. Accessories information available on the web at frigidaire.com USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FGGF3047T 10/17 © 2017 Electrolux Home Products, Inc.

  • 1
  • 2
  • 3

INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 205 Lbs.
Voltage Rating – 120V / 60 Hz / 5 Amps
Amps @ 120 Volts = 5 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated by range.
Linoleum or any other synthetic floor covering located beneath range, must
be capable of withstanding minimum heat of 90° F above room temperature
without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood
required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base or
beneath lower front panel of range. Range requires fresh air for proper burner
combustion.
Do not install range beneath any downward-blowing, overhead vent hood
or air curtain.
Range ships with 3/4" factory regulator.
Range is LP Gas convertible.
(Optional LP Gas conversion kit available.)
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets installed
to either side of appliance must be no less than maximum width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum clearance required
(from edge of rangetop to nearest combustible
wall on either side of range above 36" height)
is based on largest burner
output rating on cooking surface.
To reduce risk of fire when using overhead cabinetry, install range hood that
projects horizontally a recommended minimum of 5" beyond bottom of cabinets.
Follow all dimension requirements provided to prevent property damage,
potential fire hazard, and incorrect countertop and cabinet cuts..
OPTIONAL ACCESSORIES
LP Gas Conversion Kit – (PN # GRLP4).
Griddle - Included
Specifications subject to change.
Accessories information available on the web at
frigidaire.com
Note:
For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FGGF3047T 10/17
© 2017 Electrolux Home Products, Inc.
30" min.
13"
max.
25"
Minimum
clearance
(A)
required to
nearest
combustible
wall on
either side
of range
above 36"
height
30"
C
L
36"
stand.
Wall
15"
11
1
/
2
"
Recommended area for through-the-floor
connection of pipe stub and shutoff valve
8"
Recommended area for 120V outlet on rear of
wall and area for through-the-wall connection
of pipe stub and shutoff valve
23"
18"
min.
24"
10
1
/
2
"
2"
18"
min.
Front
29
7
/
8
"
48
1
/
2
"
max.
46
5
/
8
"
Side
25
3
/
4
"
29
1
/
4
"
30"
min.*
Clearance (A)
Based on Largest
Minimum
Burner Output Rating
Clearance
on Cooking Surface
Required
9,500 BTU or less
2"
10,000
-
16,999 BTU
3"
17,000 BTU or greater
5"
* Min. distance from cooking surface
to underside of overhead cabinetry
36"
(Adjustabl
e
to ±
1
/
8
")
Gas inlet location
(right bottom rear*)
Power cord location
(left bottom rear*)
*when viewed from front
Note:
Overall
product dimensions
are model specific
and may vary slightly
from illustration. Refer
to model’s product
specifications for
actual dimensions.
FGGF3047TF
FREESTANDING RANGE
30" GAS