Frigidaire FGGH3047VD Product Specifications Sheet - Page 3

Installation Specifications, Freestanding Range - canada

Page 3 highlights

Baseline FGGH3047V D/F FREESTANDING RANGE 30" GAS Minimum 5" clearance required to nearest combustible wall on either side of range 30" min. 30" 18" min.* min. above 36" height Wall CL 13" max. 18" min. 30" min. 47 " 61/2" 36" 25" max. 4" 22 5/8" stand. 121/16" 8" 121/16" Area MUST remain clear 41/3" Recommended area for 120V outlet on rear of wall Recommended area for through-the-wall or through- the-floor connection of pipe stub and shutoff valve Front *Note: 30" minimum clearance between top of cooking surface and bottom of unprotected wood or metal overhead cabinet; or 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/4" flame-retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. 0" clearance is minimum for rear of range. Follow all dimension requirements provided above to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts. Side 29" 26 3/4" Gas inlet location (right bottom rear*) Power cord location (middle bottom rear*) *when viewed from front 36 5/8" (Adjustable to ±1/4" max.) 29 7/8" INSTALLATION SPECIFICATIONS • PProduct Shipping Weight (approx.) - 220 Lbs. • Voltage Rating - 120V / 60 Hz / 5 Amps • Amps @ 120 Volts = 5 Amps • Always consult local and national electric and gas codes. • Make sure wall coverings around range can withstand heat generated by range. • Linoleum or any other synthetic floor covering located beneath range, must be capable of withstanding minimum heat of 90° F above room temperature without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood required between range and a carpeted floor. • Do not obstruct flow of combustion air at oven vent nor around base or beneath lower front panel of range. Range requires fresh air for proper burner combustion. • Do not install range beneath any downward-blowing, overhead vent hood or air curtain. • Range ships with 3/4" factory regulator. • Range is LP Gas convertible. (Optional LP Gas conversion kit available.) • Floor beneath range MUST be solid and level. • Overhead cabinetry should not exceed a 13" maximum depth. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Range can be installed flush to wall with 0" minimum rear clearance. • Minimum clearance required (from edge of rangetop to nearest combustible wall on either side of range above 36" height) is based on largest burner output rating on cooking surface. • To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Follow all dimension requirements provided to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts. OPTIONAL ACCESSORIES • LP Gas Conversion Kit - (PN # GRLP4). • Griddle - (Included). Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.ca. Specifications subject to change. Accessories information available on the web at frigidaire.ca USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FGGH3047V 08/19 © 2019 Electrolux Home Products, Inc.

  • 1
  • 2
  • 3

INSTALLATION SPECIFICATIONS
PProduct Shipping Weight (approx.) – 220 Lbs.
Voltage Rating – 120V / 60 Hz / 5 Amps
Amps @ 120 Volts = 5 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated by
range.
Linoleum or any other synthetic floor covering located beneath range, must
be capable of withstanding minimum heat of 90° F above room temperature
without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood
required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base or
beneath lower front panel of range. Range requires fresh air for proper burner
combustion.
Do not install range beneath any downward-blowing, overhead vent hood or
air curtain.
Range ships with 3/4" factory regulator.
Range is LP Gas convertible. (Optional LP Gas conversion kit available.)
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets installed to
either side of appliance must be no less than maximum width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum clearance required (from edge of rangetop to nearest combustible
wall on either side of range above 36" height) is based on largest burner
output rating on cooking surface.
To reduce risk of fire when using overhead cabinetry, install range hood that
projects horizontally a recommended minimum of 5" beyond bottom of
cabinets.
Follow all dimension requirements provided to prevent property damage,
potential fire hazard, and incorrect countertop and cabinet cuts.
OPTIONAL ACCESSORIES
LP Gas Conversion Kit – (PN # GRLP4).
Griddle - (Included).
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
Note:
For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.ca.
Specifications subject to change.
Accessories information available on the web at
frigidaire.ca
FGGH3047V 0
8
/19
© 2019 Electrolux Home Products, Inc.
FGGH3047V D/F
FREESTANDING RANGE
30" GAS
29"
47
"
*
Note:
30"
minimum clearance between top of cooking
surface and bottom of unprotected wood or metal
overhead cabinet; or 24"
minimum clearance when
bottom of wood or metal overhead cabinet is protected
by not less than 1/4" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or 0.020" copper.
0"
clearance is minimum for rear of range. Follow all
dimension requirements provided above to prevent
property damage, potential fire hazard, and incorrect
countertop and cabinet cuts.
12
1
/
16
"
30"
min.
13"
max.
25"
max.
Minimum
5" clearance
required
to nearest
combustible
wall on
either side
of range
above 36"
height
C
L
36"
stand.
30"
min.*
Recommended area for 120V outlet on rear of wall
18"
min.
8"
6
1
/
2
"
18"
min.
22
5
/
8
"
Wall
4"
4"
4
1
/
3
"
Front
Gas inlet location
(right bottom rear*)
Power cord location
(middle bottom rear*)
*when viewed from front
29
7
/
8
"
36
5
/
8
"
(Adjustabl
e
to ±
1
/
4
"
max.)
Side
30"
min.
Area MUST remain clear
26
3
/
4
"
12
1
/
16
"
Recommended area for through-the-wall or through-
the-floor connection of pipe stub and shutoff valve