PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time 74 to 84% 100% Freezer Temperature -5° to 2° F (-20° to -17° C) -1° to 3° F (-18° to -16° C) Refrigerator Temperature 34° to 39° F (1° to 4° C) 34° to 39° F (1° to 4° C) Low Side Pressure (cut-in) 5 to 12 psig (34 to 83 kPa) N/A Low Side Pressure (cut-out) -2 to 2 psig ( -14 to 14 kPa) -2 to 2 psig (-14 to 14 kPa) High Side Pressure (last 1/3 cycle) 85 to 95 psig (586 to 655 kPa) 120 to 135 psig (827 to 931 kPa) Wattage (last 1/3 cycle) 45 to 55 60 to 70 Amps (running) .6 to 1.1 .7 to .9 Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS Cabinet Size Thermostat Cut-in Cut-out Watts Heater Ohms 26' & 28' SD, 23' CD 25° F (-4° C) 47° F (8° C) 500 31 Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running ICE MAKER SPECIFICATIONS Electrical 115 vac (127 vac max) Thermostat Opens at 48° F ( 9° C), Closes at 15° F ( -9° C) Heater Voltage 85 vac ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green/Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral important safety NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. Caution All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. NOTE This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A "d" in the freezer temperature window and "F" in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A "d" and "F" will be displayed until the defrost cycle is complete. IMPORTANT PLEASE RETURN THIS SHEET TO IT'S ORIGINAL LOCATION. service data sheet 240389643 ICE & WATER - AUTOMATIC DEFROST BOTTOM FREEZER - R134a Ice Maker Errors Displayed on "UI" ERROR Ice Ice Ice Ice Er IM/RAM Error (on POR only)Detection - on POR only. This error is detected as "no com/data link with IM" by ERF 2500++ system controller (PB). IP Invalid Protocol (this error is detected when the version of I/M pcb does not match version of 2500++ system controller) CE IM Com Lost only after POR(no communication between the I/M pcb and the 2500++ system controller.) t3 TH3 Error (open or short) This error is detected when the thermister has failed on the suction line of the I/M. Test 48C 49C 50C 51C 52C 54C 56C 55C Diagnostic Mode Activate: Hold FF (+) and FZ (+) for 5 sec. Freezer Recover Mode, "1" ok "Fr" Recovery mode, Icemaker in "off" state. (See Note) EEV On=Open Off=Closed , EEV must be in the open state for sealed system evacuation. Com Link "1" ok "ER" error Note: 57C 58C 59C See Service Manual for complete description. Fan test, on or off Ice level sensor switch test Fill limit switch test (See Note) TH1 Status "1" ok "ER" Replace 60C Freeze limit switch test (See Note) TH3 Status "1" ok "ER" Replace 61C Mold heater test, on or off 62C Finger evap heater, on or off 63C Water valve test (See Note) 64C De-activate: Hold FF (+) for 5 sec. IM evap heater test EEV test Harvest motor system test (See Note) Software version System Error Codes Displayed on "UI" ERROR Test OP or 2 Freezer Sensor OPEN 1 SH or 3 Freezer Sensor SHORTED 2 OP or 2 FF Sensor OPEN 3 SH or 3 FF Sensor SHORTED 8 SY EF Evaporator Fan Circuit 9 SY CE Communication error 10 SY CF Communication error 11 dF In Manual Defrost 41 12 To initiate manual defrost press and hold, for 5 sec. FF(+) and FF(-), (d) and (f) 38 will be displayed. 15 Diagnostic Mode Activate: FZ (+) and FZ (-) for 5 sec. Standard compressor Defrost heater FF lighting Water valve,water disp. FZ lighting Auger motor Cube/crush solenoid Perfect Temp Drawer VCC Condensor fan VCC Compressor Note: See Service Manual for complete description. 22 Damper 23 Fresh food door 24 Freezer door 26 Defrost limit switch 28 Dispenser paddle 36 Ice door 29 FF Thermistor 30 FZ Thermistor 33 Ambient Thermistor 0- Software version Evaporator fan De-activate: Hold FF (+) for 5 sec. FREEZER iCE MAKER INFORMATION Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Adjustment Motor Gear Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Mounting Plate Screw LINE POWER BLK ICE MAKER BLK BRN P-3 THERMAL CUT-OUT ICE MAKER GRN / YEL P-1 MOLD BLK MOTOR RED HOLD SWITCH NO YEL RED C NC THERMOSTAT NO BLK MOLD HEATER 165 WATTS BLU C NC NO SHUT-OFF SWITCH MOUNTING PLATE ICE MAKER C NC WATER FILL SWITCH LT. BLU GRN / YEL YEL RED LT. BLU YEL WATER VALVE N ICE MAKER TUR Mounting Plate Screws Timing Gear NEUTRAL P-4 P-2 FF Ice Maker (2419801)

  • 1
  • 2

SERVICE DATA SHEET
240389643
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only.
Untrained persons should not attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to
their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.
NOTE
This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual
defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-)
keys for 5 seconds. A “d” in the freezer temperature window and “F” in the refrigerator
temperature window will display when the heater is activated. To deactivate manual
defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-)
keys for 5 seconds. A “d” and “F” will be displayed until the defrost cycle is complete.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING
Type A with Run/Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
74 to 84%
100%
Freezer Temperature
-5° to 2° F (-20° to -17° C)
-1° to 3° F
(-18° to -16° C)
Refrigerator Temperature
34° to 39° F (1° to 4° C)
34° to 39° F
(1° to 4° C)
Low Side Pressure
(cut-in)
5 to 12 psig
(34 to 83 kPa)
N/A
Low Side Pressure
(cut-out)
-2 to 2 psig
( -14 to 14 kPa)
-2 to 2 psig
(-14 to 14 kPa)
High Side Pressure (last 1/3 cycle)
85 to 95 psig
(586 to 655 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle)
45 to 55
60 to 70
Amps (running)
.6 to 1.1
.7 to .9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
26’ & 28’ SD, 23’ CD
25° F (-4° C)
47° F (8° C)
500
31
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Heater Voltage
85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green/Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
IMPORTANT
PLEASE RETURN THIS SHEET TO IT’S ORIGINAL LOCATION.
Ice Maker Errors Displayed on “UI”
Diagnostic Mode
Note:
See Service Manual for
complete description.
ERROR
Test
Activate: Hold FF (+) and FZ (+)
for 5 sec.
Ice
Er
IM/RAM Error
(on POR only)Detection – on POR
only. This error is detected as “no com/data link
with
IM”
by
ERF 2500++ system controller (PB).
48C
Freezer Recover Mode, “1” ok
“Fr” Recovery mode, Icemaker in
“off” state. (See Note)
57C
Fan test, on or off
Ice
IP
Invalid Protocol (this error is detected when the
version of I/M pcb does not match version of 2500++
system controller)
49C
EEV On=Open Off=Closed , EEV
must be in the open state for sealed
system evacuation.
58C
Ice level sensor switch test
Ice
CE
IM Com Lost only after POR(no communication
between the I/M pcb and the 2500++ system
controller.)
50C
Com Link “1” ok “ER” error
59C
Fill limit switch test
(See Note)
Ice
t3
TH3 Error (open or short) This error is detected
when the thermister has failed on the suction line
of the I/M.
51C
TH1 Status “1” ok
“ER” Replace
60C
Freeze limit switch test
(See Note)
52C
TH3 Status “1” ok
“ER” Replace
61C
IM evap heater test
54C
Mold heater test, on or off
62C
EEV test
56C
Finger evap heater, on or off
63C
Harvest motor system test
(See Note)
55C
Water valve test (See Note)
64C
Software version
De-activate: Hold FF (+) for 5 sec.
System Error Codes Displayed on “UI”
Diagnostic Mode
Note:
See Service Manual for
complete description.
ERROR
Test
Activate: FZ (+) and FZ (-) for
5 sec.
OP or 2
Freezer Sensor OPEN
1
Standard compressor
22
Damper
SH or 3
Freezer Sensor SHORTED
2
Defrost heater
23
Fresh food door
OP or 2
FF Sensor OPEN
3
FF lighting
24
Freezer door
SH or 3
FF Sensor SHORTED
8
Water valve,water disp.
26
Defrost limit switch
SY
EF
Evaporator Fan Circuit
9
FZ lighting
28
Dispenser paddle
SY
CE
Communication error
10
Auger motor
36
Ice door
SY
CF
Communication error
11
Cube/crush solenoid
29
FF Thermistor
dF
In Manual Defrost
41
Perfect Temp Drawer
30
FZ Thermistor
12
VCC Condensor fan
33
Ambient Thermistor
To initiate manual defrost press and hold,
for 5 sec. FF(+) and FF(-),
(d) and (f)
will be displayed.
38
VCC Compressor
0-
Software version
15
Evaporator fan
De-activate: Hold FF (+) for 5 sec.
FF Ice Maker
(2419801)
FREEZER ICE MAKER INFORMATION
Test Cycling:
Remove cover by inserting
screwdriver in notch at
bottom and prying cover
from housing. Use screwdriver to rotate motor
gear counterclockwise until holding switch circuit
is completed. All components of ice maker should
function to complete the cycle.
Water Fill Volume:
The water fill adjust
-
ment screw will change the fill time. One full turn
is equal to 20cc (.68 oz.). The correct fill is 102
to 130cc (3.4 to 4.3 oz.). When a water valve is
replaced, the fill volume must be checked.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
POWER
ICE MAKER
I
CE MAKER
ICE
MAKER
WA
TER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUT-OFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
LT. BLU
LT
. BLU
BRN
RED
GRN / YEL
GRN / YEL
RED
RED
YEL
YEL
YEL
P-3
P-1
P-2
P-4
ICE MAKER