Page 1 highlights

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time 25 to 35% 45 to 55% Freezer Temperature 2° to 8°F (-17° to -13°C) 0° to 5°F (-18° to -15°C) Refrigerator Temperature 35° to 40°F (2° to 4°C) 35° to 40°F (1° to 4°C) Low Side Pressure (cut-in) 8 to 16 psig ( 55 to 110 kPa) 8 to 16 psig (55 to 110 kPa) Low Side Pressure (cut-out) 1 to 4 psig (7 to 28 kPa) 1 to 4 psig (7 to 28 kPa) High Side Pressure (last 1/3 cycle) 110 to 120 psig (758 to 827 kPa) 150 to 175 psig (1034 to 1207 kPa) Wattage (last 1/3 cycle) 140 to 185 140 to 185 Amps (running) 1.1 to 1.6 1.1 to 1.6 Base Voltage 115 vac (127 vac max) 115 vac (127 vac max) Refrigerant Charge 4.25 oz. (121 g) DEFROST SPECIFICATIONS Safety Thermostat Heater Defrost Thermistor Cabinet Size: 18'/20' Cut-in Cut-out Watts Ohms Termination 110°F (43.3°C) 135°F (57.2°C) 375 35 47°F (8.3°C) CONDENSER FAN MOTOR Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running EVAPORATOR FAN MOTOR Watts RPM Amps 6.2 2600 CW 0.05 Running ICE MAKER SPECIFICATIONS Electrical 115 vac (127 vac max) 60 Hertz Thermostat Heater Wattage Opens at 48°F (9°C) 165 vac Closes at 15°F ( -9°C) (ice maker with black housing) 9°F (-13°C) (ice maker with white housing) ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green / Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral ICE MAKER INFORMATION Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. SERVICE DATA SHEET STANDARD - AUTOMATIC DEFROST TOP MOUNT FREEZER - R134a A01511901 IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. IMPORTANT PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. SERVICE MODE SERVICE MODE will step through available tests to diagnose individual electrical circuits. Fresh Food compartment light will be OFF while in SERVICE MODE. enter/exit --> Press the door switch 3 times and hold the 4th press until 1 long beep is heard. The door switch must be pressed 4 times in 2 seconds. initiate first/next test --> Press the door switch 2 times; 2 short beeps acknowledge selection. 1 Compressor 2 Heater 3 FF Light 4 Evaporator Fan Press the FF door switch twice to start the first test. In each test, the component listed will be powered on. The component will stay powered until the next test is activated, or until 5 minutes of inactivity expire. Listen for operating sounds; feel for heat or air flow, as appropriate, to determine the result of each test. Press the FF door switch twice again to advance between tests. Two beeps will sound to confirm the next test has started. CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. DOOR AJAR ALARM Condition: Fresh Food Door is left open for more than 5 minutes and alarm sounds. Duration: Alarm will sound for 2 minutes, then stop. If the "Door Ajar" condition remains, the alarm will repeat every 30 minutes for two intervals. Fresh Food Light: After 15 minutes of "Door Ajar" condition, the Fresh Food light will turn off. Reset: Close the Fresh Food door or Press the Fresh Food Door switch. MANUAL DEFROST Unit will complete normal defrost cycle. enter --> Press the FF door switch 5 times in 2 secs.; Alarm sounds 5 short beeps to acknowledge MANUAL DEFROST. exit --> Cycle power to the unit or enter and exit SERVICE MODE. (See SERVICE MODE) Defrost is terminated when defrost thermistor located on the evaporator coil reaches 47°F. Safety Thermostat in the defrost circuit is a safety device only. It will interrupt power to the defrost heater at 135°F. Normal Cooling Service Mode Mode Press Door Switch 3 Press Door Switch Times and Hold 4th Press Until 2 Times Long Beep Test 1: 2 Beeps Test 2: Power ON Press Door Switch Compressor ON Enters Service 2 Times Mode 2 Beeps Press Door Switch 2 Times Manual Defrost 2 Beeps to Defrost Heater To Exit Service Mode from Press Door Switch any Test Press Door Switch 2 Times 3 Times and Hold 4th Press 2 Beeps Press Door Switch 5 Times to Enter Manual Defrost. POR or Enter Service Mode to Exit Manual Defrost. Test 4: Evaporator Fan ON Press Door Switch 2 Times 2 Beeps Test 3: Fresh Food Light ON P/N A01437001 108 mm TEMPERATURE/RESISTANCE CHART FOR FRESH FOOD THERMISTOR AND DEFROST THERMISTOR °F kOHMS °F kOHMS °F kOHMS °F kOHMS -10 83.88 11 47.25 32 27.20 53 16.87 -9 81.56 12 46.02 33 27.04 54 16.49 -8 79.32 13 44.84 34 26.38 55 16.13 -7 77.15 14 43.67 35 25.75 56 16.77 -6 75.04 15 42.55 36 25.13 57 15.41 -5 73.02 16 41.45 37 24.53 58 15.07 -4 71.02 17 40.39 38 23.95 59 14.74 -3 69.08 18 39.36 39 23.38 60 14.42 -2 67.16 19 38.36 40 22.83 61 14.10 -1 65.34 20 37.39 41 22.29 62 13.79 0 63.55 21 36.44 42 21.77 63 13.49 1 61.82 22 35.53 43 21.26 64 13.21 2 60.15 23 34.63 44 20.77 65 12.92 3 58.20 24 33.78 45 20.29 66 12.65 4 56.97 25 32.94 46 19.83 67 12.38 5 55.43 26 32.13 47 19.37 68 12.11 6 53.97 27 31.33 48 18.92 69 11.85 7 52.53 28 30.57 49 18.49 70 11.60 8 51.16 29 29.83 50 18.07 71 11.36 9 49.81 30 29.10 51 17.66 72 11.12 10 48.51 31 28.39 52 17.26 73 10.88

  • 1
  • 2

SERVICE DATA SHEET
A01511901
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only.
Untrained persons should not attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their
original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
TEMPERATURE/RESISTANCE CHART
FOR FRESH FOOD THERMISTOR AND DEFROST THERMISTOR
°F
kOHMS
°F
kOHMS
°F
kOHMS
°F
kOHMS
-10
83.88
11
47.25
32
27.20
53
16.87
-9
81.56
12
46.02
33
27.04
54
16.49
-8
79.32
13
44.84
34
26.38
55
16.13
-7
77.15
14
43.67
35
25.75
56
16.77
-6
75.04
15
42.55
36
25.13
57
15.41
-5
73.02
16
41.45
37
24.53
58
15.07
-4
71.02
17
40.39
38
23.95
59
14.74
-3
69.08
18
39.36
39
23.38
60
14.42
-2
67.16
19
38.36
40
22.83
61
14.10
-1
65.34
20
37.39
41
22.29
62
13.79
0
63.55
21
36.44
42
21.77
63
13.49
1
61.82
22
35.53
43
21.26
64
13.21
2
60.15
23
34.63
44
20.77
65
12.92
3
58.20
24
33.78
45
20.29
66
12.65
4
56.97
25
32.94
46
19.83
67
12.38
5
55.43
26
32.13
47
19.37
68
12.11
6
53.97
27
31.33
48
18.92
69
11.85
7
52.53
28
30.57
49
18.49
70
11.60
8
51.16
29
29.83
50
18.07
71
11.36
9
49.81
30
29.10
51
17.66
72
11.12
10
48.51
31
28.39
52
17.26
73
10.88
PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A With Run/Start Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
25 to 35%
45 to 55%
Freezer Temperature
2° to 8°F (-17° to -13°C)
0° to 5°F
(-18° to -15°C)
Refrigerator Temperature
35° to 40°F (2° to 4°C)
35° to 40°F
(1° to 4°C)
Low Side Pressure (cut-in)
8 to 16 psig
( 55 to 110 kPa)
8 to 16 psig (55 to 110 kPa)
Low Side Pressure (cut-out)
1 to 4 psig (7 to 28 kPa)
1 to 4 psig (7 to 28 kPa)
High Side Pressure
(last 1/3 cycle)
110 to 120 psig
(758 to 827 kPa)
150 to 175 psig
(1034 to 1207 kPa)
Wattage (last 1/3 cycle)
140 to 185
140 to 185
Amps (running)
1.1 to 1.6
1.1 to 1.6
Base Voltage
115 vac (127 vac max)
115 vac (127 vac max)
Refrigerant Charge
4.25 oz. (121 g)
DEFROST SPECIFICATIONS
Cabinet Size: 18’/20’
Safety Thermostat
Heater
Defrost
Thermis-
tor
Cut-in
Cut-out
Watts
Ohms
Termina-
tion
110°F
(43.3°C)
135°F
(57.2°C)
375
35
47°F
(8.3°C)
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
EVAPORATOR FAN MOTOR
Watts
RPM
Amps
6.2
2600 CW
0.05 Running
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
60 Hertz
Thermostat
Opens at 48°F (9°C)
Closes at 15°F ( -9°C) (ice maker
with black housing)
9°F (-13°C) (ice maker
with white housing)
Heater Wattage
165 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow
Water Valve
3
Black
Line
4
Light Blue
Neutral
ICE MAKER INFORMATION
Test Cycling:
Remove cover by
inserting screwdriver in notch at
bottom and prying cover from housing. Use screwdriver to rotate motor gear counter-
clockwise until holding switch circuit is completed. All components of ice maker should
function to complete the cycle.
Water Fill Volume:
The water fill adjustment screw will change the fill time. One
full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.).
When a water valve is replaced, the fill volume must be checked.
Normal Cooling
Mode
Enters Service
Mode
Test 1:
Compressor
ON
Test 4:
Evaporator
Fan
ON
Test 2:
Power
ON
to Defrost Heater
To Exit Service Mode from
any Test Press Door Switch
3 Times and Hold 4th Press
Service Mode
Test 3:
Fresh
Food Light
ON
Press Door Switch
2 Times
2 Beeps
Press Door Switch 3
Times and Hold 4th Press Until
Long Beep
Manual Defrost
Press Door Switch 5 Times to
Enter Manual Defrost. POR
or Enter Service Mode to Exit
Manual Defrost.
Press Door Switch
2 Times
2 Beeps
Press Door Switch
2 Times
2 Beeps
Press Door Switch
2 Times
2 Beeps
Press Door Switch
2 Times
2 Beeps
DOOR AJAR ALARM
Condition:
Fresh Food Door is left open for more than 5 minutes and alarm sounds.
Duration:
Alarm will sound for 2 minutes, then stop. If the “Door Ajar” condition remains,
the alarm will repeat every 30 minutes for two intervals.
Fresh Food Light:
After 15 minutes of “Door Ajar” condition, the Fresh Food light will turn off.
Reset:
Close the Fresh Food door or Press the Fresh Food Door switch.
MANUAL DEFROST
Unit will complete normal defrost cycle.
enter
--> Press the FF door switch 5 times in 2 secs.; Alarm sounds 5 short beeps
to acknowledge MANUAL DEFROST.
exit
--> Cycle power to the unit or enter and exit
SERVICE MODE.
(See SERVICE MODE)
Defrost is terminated when defrost thermistor located on the evaporator coil reaches 47°F.
Safety Thermostat in the defrost circuit is a safety device only. It will interrupt power to the defrost
heater at 135°F.
SERVICE MODE
SERVICE MODE will step through available tests to diagnose individual electrical circuits. Fresh
Food compartment light will be OFF while in SERVICE MODE.
enter/exit
--> Press the door switch 3 times and hold the 4th press until 1 long
beep is heard. The door switch must be pressed 4 times in 2 seconds.
initiate first/next test
--> Press the door switch 2 times; 2 short beeps acknowledge selection.
1
Compressor
Press the FF door switch twice to start the first test.
In each test, the
component listed will be powered on. The component will stay powered
until the next test is activated, or until 5 minutes of inactivity expire. Listen
for operating sounds; feel for heat or air flow, as appropriate, to determine
the result of each test. Press the FF door switch twice again to advance
between tests. Two beeps will sound to confirm the next test has started.
2
Heater
3
FF Light
4
Evaporator Fan