Frigidaire FGIP2468UD Product Specifications Sheet - Page 3

Front, Right

Page 3 highlights

24" Built-In Dishwasher with Integrated Controls (IC), PFlGaIsP2t4ic68TUuFb (PT) & Integrated handle (IH)_Frig Gallery DISHWASHER 24" BUILT-IN Front 24" Left 25" Right 49 1/4" 22 1/2" 33 1/2" Adjustable to 35" Door in 90° open position Water inlet (left bottom front) Power supply location (right bottom front) 90° 341/4" min. 24" min. 90° Electrical, water, and drain lines must be confined to shaded area 18" 4" 7 3/4" 3" Hot Electrical water wiring 6" line 6" 2 1/2" 2 1/2" 24" INSTALLATION SPECIFICATIONS • Product Shipping Weight (approx.) - 83 Lbs. • Voltage Rating - 120V / 60 Hz / 15 Amps (maximum 20 Amps if connected with disposer) • Connected Load (kW Rating) @ 120 Volts = 1.20kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120V = 10 Amps • Always consult local and national electric & plumbing codes. Meets requirements of ASSE 1006 - integral air gap on supply. • Water Pressure - Hot water line to dishwasher must provide between 20 and 120 pounds per square inch (psi) with at least 120° F hot water temperature. • Make sure location has correct drain, water and electrical outlets to make connections - MUST be confined to shaded areas. • Electrical and water supplies should enter cabinet opening on floor, or through back or side walls, as shown in shaded areas. • Keep back free of drain, water & electrical supply. • Connections preferably located toward left side of dishwasher. Do not cross drain, water or electrical lines in front of motor, blower or frame. • If connecting drain hose to sink trap, local code may require installation of Air Gap Kit (not included). • Leveling legs supplied to adjust height. • When installing adjacent to wall, cabinet or other obstruction that extends beyond front edge of unit, allow 2" minimum clearance between opened door and obstruction. • Floor should be flat and free of obstructions with carpet removed to provide motor clearance. • When installing at end of cabinet line, sides and back must be fully enclosed. • Do not install unit under a cooktop, damage will occur. • Recommended to seal cabinets, enclosing all sides of dishwasher, including underside of countertop, with oil-based paint or moisture-proof polyurethane to prevent possible steam/moisture damage. Meets requirements of ASSE 1006 Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com. Specifications subject to change. Accessories information available on the web at frigidaire.com USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FGIP2468U 02/19 © 2019 Electrolux Home Products, Inc.

  • 1
  • 2
  • 3

INSTALLATION SPECIFICATIONS
Product Shipping Weight (approx.) – 83 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
(maximum 20 Amps if connected
with disposer)
Connected Load (kW Rating) @ 120 Volts = 1.20kW
(For use on adequately wired 120V, dedicated circuit having 2-wire service
with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120V = 10 Amps
Always consult local and national electric & plumbing codes. Meets
requirements of ASSE 1006 — integral air gap on supply.
Water Pressure – Hot water line to dishwasher must provide between 20 and
120 pounds per square inch (psi) with at least 120° F hot water temperature.
Make sure location has correct drain, water and electrical outlets to make
connections — MUST be confined to shaded areas.
Electrical and water supplies should enter cabinet opening on floor, or through
back or side walls, as shown in shaded areas.
Keep back free of drain, water & electrical supply.
Connections preferably located toward left side of dishwasher. Do not cross
drain, water or electrical lines in front of motor, blower or frame.
If connecting drain hose to sink trap, local code may require installation of
Air Gap Kit
(not included)
.
Leveling legs supplied to adjust height.
When installing adjacent to wall, cabinet or other obstruction that extends
beyond front edge of unit, allow 2" minimum clearance between opened door
and obstruction.
Floor should be flat and free of obstructions with carpet removed to provide
motor clearance.
When installing at end of cabinet line, sides and back must be fully enclosed.
Do not install unit under a cooktop, damage will occur.
Recommended to seal cabinets, enclosing all sides of dishwasher, including
underside of countertop, with oil-based paint or moisture-proof polyurethane
to prevent possible steam/moisture damage.
6"
2
1
/
2
"
2
1
/
2
"
4"
18"
24"
min.
Electrical, water,
and drain
lines
must be confined
to shaded
area
6"
24"
7
3
/
4
"
90°
90°
3"
34
1
/
4
"
min.
Hot
water
line
Electrical
wiring
Front
33
1
/
2
"
Adjustable
to 35"
24"
Power supply location (right bottom front)
49
1
/
4
"
22
1
/
2
"
Right
Left
25"
Water inlet
(left bottom front)
Door in 90°
open position
FGIP2468UF
DISHWASHER
24" BUILT-IN
Meets
requirements of
ASSE 1006
Specifications subject to change.
Accessories information available on the web at
frigidaire.com
Note:
For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FGIP2468U 02/19