Frigidaire FMV152KB Wiring Diagram (All Languages) - Page 1
Frigidaire FMV152KB - 1.5 Cu Ft Microwave Manual
UPC - 012505560163
View all Frigidaire FMV152KB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
MICROWAVE OVEN TECH SHEET CAUTION Disconnect from Electrical Supply Before Servicing Unit PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID PROSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY A. Do not operate or allow the oven to be operated with the door open. B. Make the following safety checks on all ovens to be serviced before activating the Magnetron or other microwave source, and make repairs as necessary. 1. Interlock operating. 2. Proper door closing. 3. Seal and sealing surfaces ( Arcing, wear and other damage.) 4. Damage to or loosening of hinges and latch. 5. Evidence of dropping or abuse. C. Before turning on microwave power for any service test or inspection within the microwave generating compartments. check the magnetron. Waveguide or transmission line. And cavity for proper alignment, integrity and connection. D. Any detective or mis-adjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired. replaced. or adjusted by producers. designed in this manual before the oven Is released to the owner. E. A microwave leakage check to verify Compliance with the Federal performance Standard should be performed on each oven prior to release to the owner. F. Do not attempt to operate the oven if the door glass is broken. OVEN THERMOSTAT Parts Layout VENT MOTOR MOTOR CONDENSER NOISE FILTER OVEN LAMP T/TABLE MOTOR COOK TOP LAMPS Made in china PRIMARY SWITCH H.V.CAPACITOR H.V.DIODE MAGNETRON MAGNETRON THERMOSTATA MONITOR SWITCH H.V.TRANSFORMER FAN MOTOR DOOR SENSING SWITCH HOOD THERMOSTAT BOTTOM THERMOSTAT Schematic Diagram Warning : Power must be disconnected before servicing this appliance MODEL NO. : (C)/FMV152K; C/FFMV162L;C/FFMV164L Wiring Diagram Warning : Power must be disconnected before servicing this appliance MODEL NO. : (C)/FMV152K; C/FFMV162L;C/FFMV164L POWER SUPPLY : FILTER ASS'Y SINGLE PHASE ONLY BK WH GN GN CONTROL P.W.B. ASS'Y LAMP RELAY VENT RELAY OG:ORANGE BR:BROWN YW:YELLOW WH:WHITE RD:RED BK:BLACK BL:BLUE GY:GREY GN:GREEN PK:PINK 26 GY 25 BL 7 HI (RY5) 8 LOW (RY4) 9 24 BK ON (RY3) 6 23 GN 5 RD 1 L.V.T 3 22 BR SUB RELAY (RELAY 1) 4 18 OG 16 WH 21 YW 27 OG (40/70) CUT-OUT 17 BK HOOD THERMAL FUSE VENT MOTOR 1 BK CAVITY THERMAL CUT-OUT (1 10/0) MOTOR CAPACITOR 28 GN 29 YW T.P. 19 YW 20 BL L COOKTOP LAMP L L 120V OVEN LAMP 120V TURNTABLE MOTOR TTM FAN MOTOR FM 6 YW 15 WH 12 WH POWER RELAY (RELAY 2) 10 BK MONITOR INTERLOOK SWITCH 9 WH 11 WH 12 11 H.V. TRANS F 31 WH 32 YW DOOR SENSE SWITCH (BOTTOM) MAGNETRON FA NOTE: Door is open H.V. CAPACITOR H.V.DIODE PRIMARY INTERLOCK ( UPPER) 8 BK 7 YW 2 BK 30 WH 4 BK CUT-OUT (1 20/0) 3 BK MGT THERMAL CUT-OUT (1 60/95) BOTTOM THERMAL 12 YW-32 WH-31 BK-24 BL-25 GY-26 GN-23 OG-18 BR-22 1 RD-5 POWER RELAY WH-12 BK-10 P C B YW-32 WH-31 BK-17 WH-15 WH-15 YW-7 WH-16 OG-18 BL-20 YW-6 BK-17 WH-16 BL-20 GN-23 WH-30 GN-28 YW-29 OG-27 BL-25 BK-1 BK-2 BK-2 BK-3 BK-3 BK-4 GY-26 BK-24 OG-27 DOOR SENSING SWITCH T/TABLE MOTOR FAN MOTOR OG:ORANGE BR:BROWN YW:YELLOW WH:WHITE RD:RED BK:BLACK BL:BLUE GN:GREEN GY:GREY PK:PINK GROUND HARNESS LEADS PARTS LEADS OVEN LAMP YW-19 YW-21 VENT MOTOR CAVITY THERMOSTAT MGT THERMOSTAT BOTTOM THERMOSTAT HOOD THERMOSTATA BK WH COOKTOP LAMP H.V.CAPACITOR RD RD WH H.V.DIODE FA MGT TUBE POWER CORD F RD H.V.TRANS GND WH-11 BK-10 WH-9 BK-8 WH BK BK-4 YW-6 YW-7 BK-8 WH-11 WH-9 GN-28 YW-29 BK-1 WH-12 BK WH PRIMARY SWITCH MONITOR SWITCH MOTOR CONDENSER OUT IN NOISE FILTER NOTE: For servicing replacement use 16GA,105 C thermoplastic covered wire except for high voltage leads or as noted on special leads. Switch Chart Component tests SWITCH CHECK BY Primary Interlock Disconnect the wires at the Primary Interlock Switch. Check from the common terminal to the normally opened terminal. Door sensing Interlock Disconnect the wires at the sensing interlock Switch. Check from the common terminal and Normally closed terminal Monitor Interlock Disconnect the wires at the Monitor Switch. Check from the common terminal and Normally closed terminal . DOOR _ _ + DOOR CLOSE + + _ L DOOR OPEN L DOOR CLOSE Primary Interlock Switch Primary Interlock Switch Door Sensing Switch Door Sensing Switch _+( ) CONTINUITY ( ) NO CONTINUITY N Monitor Interlock Switch N Monitor Interlock Switch Note: These Diagrams are not intended to show a complete circuit, they represent the position of switches during "DOOR OPEN" and "DOOR CLOSED". (continuity checks only) OUTPUT POWER OF MAGNETRON CAUTION MICROWAVE RADIATION PERSONNEL SHOULD NOT ALLOW EXPOSURE TO MICROWAVE RADIATION FROM MICROWAVE GENERATOR OTHER PARTS CONDUCTING MICROWAVE ENERGY. The output power of the magnetron can be measured by performing a water temperature rise test. Equipment needed: * Two 1-liter cylindrical borosilicate glass vessel (Outside diameter 190 mm) * One glass thermometer with mercury column NOTE: Check line voltage under load. Low voltage will lower the magnetron output. Make all temperature and time tests with accurate equipment. 1. 2. Fill the one liter glass vessel with water. Stir water in glass vessel with thermometer, and record glass vessel's temperature ("T1", 10 +_ 1 C). 3. After moving the water into another glass vessel, place it in the center of the cooking tray. Set the oven to high power and operate for 47 seconds exactly. ( 3 seconds included as a holding time of magnetron oscillation) 4. When heating is finished, stir the water again with the thermometer and measure the temperature ( "T2"). 5. Subtract T1 from T2. This will give you the water temperature rise. ( T ) 6. The output power is obtained by the following formula; Output = 4.187x1000x T+0.55xMcx(T2-T0) 45 : Heating Times (sec) 42 ( 3 seconds included as a holding time of magnetron oscillation.) 4.187 : Coefficient for water 1000 : Water ( cc ) T : Temperature Rise (T2-T1) T0 : Room Temperature Mc : Cylindrical borosilicate glass weight 7. Normal temperature rise for this model is 9.9 C to 10.3 C at 'HIGH'. NOTE 1: Variations or errors in the test procedure will cause a variance in the temperature rise. Additional power test should be made if temperature rise is marginal. NOTE 2: Output power in watts is computed by multiplying the temperature rise (step 5) by a factor of 91 times the of centigrade temperature. WARNING Personal injury/Product Hazard Disconnect the power supply cord from the outlet before removing the outer cabinet from the unit. after performing any test or repairs to the microwave. Check that all wire leads are in the Discharge the high voltage capacitor and remove the lead wires from The primary winding of the high voltage transformer before conducting any of the following tests. Correct position before operating The microwave oven. Grasp wire connectors when removing the wire leads from microwave parts. Conduct all operation tests with 1 liter Failure to follow these instructions may of water in the oven. result in electrical shock or other Conduct a microwave energy test Personal injury or in product damage. High voltage components Transformer Secondary Terminal Filament Terminals Primary Terminal Magnetron Cooling Fins 1. Remove wire leads. 2. Measure resistance .( ohm meter scale: Rx1) Primary winding Secondary winding Filament winding 3. Measure resistance .( ohm meter scale: Rx1000) Primary winding to ground Filament winding to ground 1. Remove wire leads. Install the magnetron seal in the correct position .Check that the seal is in good condition. 2. Measure resistance .( ohm meter scale: Rx1) Filament winding 3. Measure resistance .( ohm meter scale: Rx1000) Filament to chassis Approx. 0.334+2% ohm. Approx. 118.7+2% ohm. 0 ohm.. Normal: Infinite. Normal: Infinite. Normal: Less than 1 ohm Normal: Infinite. Capacitor 1. Remove wire leads. 2. Measure resistance .( ohm meter scale: Rx1000) Terminal to terminal Normal: Momentarily indicates several ohm, and then gradually returns to infinite. Diode Some inexpensive Meters may indicate Infinite resistance in both directions Terminal to case 1. Measure continuity. Forward .( ohm meter scale: Rx1000) 2. Measure continuity. Reverse .( ohm meter scale: Rx1000) Normal: Infinite. Normal: Continuity. Abnormal: Infinite. Normal: Infinite. Abnormal: Continuity. Ventilation Motor 1. Remove wire leads. 2. Measure resistance .( ohm meter scale: Rx1) 2 level: White and Blue wire Approximately 35.2 ohms Components T/Table Motor Fan Motor Other component tests Test 1. Remove wire leads. 2. Measure resistance. ( ohm meter scale: Rx1000) Results Normal: Approximately: 3.3k ohms 1. Remove wire leads. 2. Measure resistance. ( ohm meter scale: Rx1) Normal: Approximately: 97.4 ohms p/n 316495069