Frigidaire FMV157GB Installation Instructions - Page 20
Adapting Microwave, Blower For Recirculation, Check Microwave Assembly - microwave parts
UPC - 012505558986
View all Frigidaire FMV157GB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation Instructions C3. CHECK MICROWAVE ASSEMBLY Exhaust Adaptor 5 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. Back of Microwave • Place the microwave in its upright position, with the top of the unit facing up. • The microwave oven may be shipped assembled for top exhaust (adaptor installed) or for recirculation exhaust (adaptor absent). • If the microwave was shipped for recirculation exhaust, remove the Exhaust Adaptor and proceed to C5. If the microwave was shipped for top exhaust, proceed to C4. C4. ADAPTING MICROWAVE BLOWER FOR RECIRCULATION 1 Remove tape securing damper. 2 Raise damper flap. Blower Plate 3 Slip the damper out of the track on the blower frame by pressing and twisting both ends. Back of Microwave 4 Remove the screw that holds the blower plate to the microwave. Remove and save the screw holding the blower motor to the microwave. 6 Roll the blower unit 90° so that fan blade openings are facing toward the front of the microwave. BEFORE: Fan Blade Openings Facing Up Roll AFTER: Fan Blade Openings Facing Forward Blower Plate Back of Microwave Blower Motor Screw NOTE: The blower plate will be reinstalled in a later step. The damper is not needed for recirculating models. Save any unused parts for possible future use. NOTE: Make sure wires remain routed in the grooves of the motor frame. 20