ERROR CODES NOTES: • C0 errors are for errors applicable to the entire appliance and the user interface board. • C1 errors are for the left powerboard. • C2 errors are for the right powerboard. • Make sure all knobs are in the OFF position when cycling power to the appliance. Leaving the knobs in any ON position will result in further error messages and prevent accurate troubleshooting. UI Display C014 C016 C122 C222 C035 C149 C249 C157 C257 C158 C258 C159 C259 C161 C261 C164 C264 C165 C265 C167 C267 C168 C268 C169 C269 C170 C270 C171 C271 C172 C272 C173 C273 C174 C274 C175 C275 Error Description Corrective Action Keyboard, LED tail failure. 1. Confirm cooktop ON indicator LED is connected on J3. 2. If problem persists, replace cooktop ON indicator setup. 3. If problem persists, replace the user interface board. Potentiometer error. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace user interface board. Loss of communication between powerboard and user interface board. 1. Check the MACS connection (communication harness) between user interface board and induction powerboards. 2. If problem persists, check continuity of MACS harness between each control board. Replace harness if defective. 3. If harness is good and problem persists, replace the induction board indicated by the error code. 4. If problem persists, replace the user interface board. ON indicator display failure: the displays 1. cannot display the LEDs properly, the 2. mechanism for the displays has failed. Cycle power to the appliance, wait 30 seconds before reconnecting power. If problem persists, replace user interface board. Induction powerboard configuration compatibility error. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. Has the appliance been recently serviced? If so, verify the part numbers of the replaced components. Incorrect replacement parts will cause software errors. 3. If parts check correctly and the problem persists, replace the induction board indicated by the error code. 4. If problem persists, replace the user interface board. MAINS (power supply) relay stuck on induction powerboard. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace the induction board indicated by the error code. 400v detection error on induction powerboard. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace the induction board indicated by the error code. Too low MAINS (power supply) voltage 1. Check line voltage coming into the appliance. detected on induction powerboard. 2. If problem persists, replace the induction board indicated by the error code. 15v supply too high or too low in induction powerboard. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace the induction board indicated by the error code. Cooling fan on the induction powerboard is blocked or otherwise unable to turn. 1. Check for interference, blockages, debris, dust, or anything else that would physically prevent the fan from moving. 2. If problem persists, replace the induction board indicated by the error code. Temperature sensor open on induction 1. Check sensor connections on the the induction board indicated by the error code. powerboard. 2. If problem persists, replace the induction board indicated by the error code. Communication loss between control and power microprocessors on induction powerboard. 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace the induction board indicated by the error code. Failure check found inconsistent 1. voltage measurement between the two 2. induction powerboard microprocessors. Cycle power to the appliance, wait 30 seconds before reconnecting power. If problem persists, replace the induction board indicated by the error code. Failure check found inconsistent 1. current measurement between the two 2. induction powerboard microprocessors. Cycle power to the appliance, wait 30 seconds before reconnecting power. If problem persists, replace the induction board indicated by the error code. Failure check found inconsistent power 1. frequency detection between the two 2. induction powerboard microprocessors. Cycle power to the appliance, wait 30 seconds before reconnecting power. If problem persists, replace the induction board indicated by the error code. Failure check found inconsistent power 1. currents between the drive circuit for the 2. coils (IGBT) and the main power current on the induction powerboard. Cycle power to the appliance, wait 30 seconds before reconnecting power. If problem persists, replace the induction board indicated by the error code. Internal syncing error between the two 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. induction powerboard microprocessors. 2. If problem persists, replace the induction board indicated by the error code. Failure check found too-high 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. temperature on induction power board. 2. If problem persists, replace the induction board indicated by the error code. Drive circuit for the coils and/or the heat 1. sink for the induction power boards has 2. a failure. Check that the sensor is installed correctly, measure approximately 100K Ohm for NTC.. If problem persists, replace the induction board indicated by the error code. Failure check found a bad sensor or a shorted circuit on the induction powerboard. 1. Check the sensor connections on the induction board indicated by the error code. 2. If problem persists, replace the induction board indicated by the error code. ERROR CODES NOTES: • C0 errors are for errors applicable to the entire appliance and the user interface board. • C1 errors are for the left powerboard. • C2 errors are for the right powerboard. • Make sure all knobs are in the OFF position when cycling power to the appliance. Leaving the knobs in any ON position will result in further error messages and prevent accurate troubleshooting. UI Display C180 C280 C181 C281 Error Description Power supply and/or frequency lost on the induction powerboard. Cooling fan not connected on the induction powerboard. Corrective Action 1. Cycle power to the appliance, wait 30 seconds before reconnecting power. 2. If problem persists, replace the induction board indicated by the error code. 1. Check cooling fan connections on the induction board indicated by the error code. 2. If problem persists, replace the induction board indicated by the error code. ADDITIONAL ERROR (FAULT) CONDITIONS Symptom or failure Control Display Pan does not heat up. Normal operation. Flashing "Power level" and pan does not heat. Individual cooking zones cannot be used or cannot always be used. Cooking power too low or shuts down prematurely. None. Normal operation HE in display when cooking "HE" zone is cold and switched off. Possible cause or condition Pan too small for proper pan detection and only works with low power. Pan not detected. Induction coil not correctly connected or induction coil open. Distance between coil and glass ceramic too large. Test cables & connections. User interface defective. Suggested Corrective Action Use larger pan or this pan on a smaller cooking zone. Refer to owners guide for proper pan selection. Check whether the pots or pans are suitable for induction. Refer to owners guide for proper pan selection. Check the coil wire terminal connections. Ensure that they are properly connected and tightened. Test continuity of coil (should be less than 1 ohm). Check whether the coil is properly positioned and touching the glass cooktop surface. 1. Follow instructions for proper use of touch controls. 2. Replace user interface. Ventilation slots obstructed. Unsuitable pots ( bottom bent). Distance between coil and glass ceramic too large. Temperature sensor defect. Clear vent openings. Follow owners guide for proper pan selection. Check whether the glass ceramic was pushed down when being screwed in position and the coil has been correctly positioned. 1. Test coil sensor , approximately 100K ohms at room temperature. Replace coil if resistance is incorrect. 2. Replace power generator board.

  • 1
  • 2
  • 3
  • 4

ERROR CODES
NOTES:
C0 errors are for errors applicable to the entire appliance and the user interface board.
C1 errors are for the left powerboard.
C2 errors are for the right powerboard.
Make sure all knobs are in the OFF position when cycling power to the appliance. Leaving the knobs in any ON position will result in further error messages
and prevent accurate troubleshooting.
UI Display
Error Description
Corrective Action
C014
Keyboard, LED tail failure.
1.
Confirm cooktop ON indicator LED is connected on J3.
2.
If problem persists, replace cooktop ON indicator setup.
3.
If problem persists, replace the user interface board.
C016
Potentiometer error.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace user interface board.
C122
C222
Loss of communication between
powerboard and user interface board.
1.
Check the MACS connection (communication harness) between user interface board and induction
powerboards.
2.
If problem persists, check continuity of MACS harness between each control board. Replace harness
if defective.
3.
If harness is good and problem persists, replace the induction board indicated by the error code.
4.
If problem persists, replace the user interface board.
C035
ON indicator display failure: the displays
cannot display the LEDs properly, the
mechanism for the displays has failed.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace user interface board.
C149
C249
Induction powerboard configuration
compatibility error.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
Has the appliance been recently serviced? If so, verify the part numbers of the replaced components.
Incorrect replacement parts will cause software errors.
3.
If parts check correctly and the problem persists, replace the induction board indicated by the error code.
4.
If problem persists, replace the user interface board.
C157
C257
MAINS (power supply) relay stuck on
induction powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C158
C258
400v detection error on induction
powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C159
C259
Too low MAINS (power supply) voltage
detected on induction powerboard.
1.
Check line voltage coming into the appliance.
2.
If problem persists, replace the induction board indicated by the error code.
C161
C261
15v supply too high or too low in
induction powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C164
C264
Cooling fan on the induction
powerboard is blocked or otherwise
unable to turn.
1.
Check for interference, blockages, debris, dust, or anything else that would physically prevent the fan
from moving.
2.
If problem persists, replace the induction board indicated by the error code.
C165
C265
Temperature sensor open on induction
powerboard.
1.
Check sensor connections on the the induction board indicated by the error code.
2.
If problem persists, replace the induction board indicated by the error code.
C167
C267
Communication loss between control
and power microprocessors on
induction powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C168
C268
Failure check found inconsistent
voltage measurement between the two
induction powerboard microprocessors.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C169
C269
Failure check found inconsistent
current measurement between the two
induction powerboard microprocessors.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C170
C270
Failure check found inconsistent power
frequency detection between the two
induction powerboard microprocessors.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C171
C271
Failure check found inconsistent power
currents between the drive circuit for the
coils (IGBT) and the main power current
on the induction powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C172
C272
Internal syncing error between the two
induction powerboard microprocessors.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C173
C273
Failure check found too-high
temperature on induction power board.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C174
C274
Drive circuit for the coils and/or the heat
sink for the induction power boards has
a failure.
1.
Check that the sensor is installed correctly, measure approximately 100K Ohm for NTC..
2.
If problem persists, replace the induction board indicated by the error code.
C175
C275
Failure check found a bad sensor
or a shorted circuit on the induction
powerboard.
1.
Check the sensor connections on the induction board indicated by the error code.
2.
If problem persists, replace the induction board indicated by the error code.
ADDITIONAL ERROR (FAULT) CONDITIONS
Symptom or failure
Control Display
Possible cause or condition
Suggested Corrective Action
Pan does not heat up.
Normal operation.
Pan too small for proper pan detec-
tion and only works with low power.
Use larger pan or this pan on a smaller cooking zone. Refer to
owners guide for proper pan selection.
Flashing "Power level"
and pan does not heat.
Pan not detected.
Check whether the pots or pans are suitable for induction. Refer to
owners guide for proper pan selection.
Induction coil not correctly
connected or induction coil open.
Check the coil wire terminal connections. Ensure that they are
properly connected and tightened. Test continuity of coil (should be
less than 1 ohm).
Distance between coil and glass
ceramic too large.
Check whether the coil is properly positioned and touching the glass
cooktop surface.
Individual cooking zones
cannot be used or cannot
always be used.
None.
Test cables & connections. User
interface defective.
1. Follow instructions for proper use of touch controls. 2. Replace
user interface.
Cooking power too low or
shuts down prematurely.
Normal operation
Ventilation slots obstructed.
Clear vent openings.
Unsuitable pots ( bottom bent).
Follow owners guide for proper pan selection.
Distance between coil and glass
ceramic too large.
Check whether the glass ceramic was pushed down when being
screwed in position and the coil has been correctly positioned.
HE in display when cooking
zone is cold and switched off.
"HE"
Temperature sensor defect.
1. Test coil sensor , approximately 100K ohms at room
temperature. Replace coil if resistance is incorrect. 2. Replace
power generator board.
ERROR CODES
NOTES:
C0 errors are for errors applicable to the entire appliance and the user interface board.
C1 errors are for the left powerboard.
C2 errors are for the right powerboard.
Make sure all knobs are in the OFF position when cycling power to the appliance. Leaving the knobs in any ON position will result in further error messages
and prevent accurate troubleshooting.
UI Display
Error Description
Corrective Action
C180
C280
Power supply and/or frequency lost on
the induction powerboard.
1.
Cycle power to the appliance, wait 30 seconds before reconnecting power.
2.
If problem persists, replace the induction board indicated by the error code.
C181
C281
Cooling fan not connected on the
induction powerboard.
1.
Check cooling fan connections on the induction board indicated by the error code.