Frigidaire FPRU19F8RF Wiring Diagram - Page 1

Frigidaire FPRU19F8RF Manual

Page 1 highlights

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Capacitor Run or Induction Run 70°F (21°C) Ambient 90°F (32°C) Ambient Operating Time 10 to 20% 20 to 30% Refrigerator Temperature 35° to 40° F 2° to 4° C 35° to 40° F 2° to 4° C Low Side Pressure (cut-in) 25 to 30 psig 175 to 205 kPa 25 to 30 psig 175 to 205 kPa Low Side Pressure (cut-out) 10 to 15 psig 70 to 100 kPa 10 to 15 psig 70 to 100 kPa High Side Pressure (last 1/3 cycle) 120 to 130 psig 810 to 880 kPa 175 to 185 psig 1180 to 1260 kPa Wattage (last 1/3 cycle) 120 to 180 140 to 155 Amps (running) .8 to 1.3 1.0 to 1.5 Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS Cabinet Size Thermostat Cut-in Cut-out Heater Watts Ohms 19' 37° F (3° C) 47° F (8° C) 550 24 Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time. CONDENSER FAN MOTOR Watts RPM Amps 2.3 1100 CW Opposite Shaft 0.13 Running important safety notice The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing. important If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured. caution: All electrical parts and wiring must be shielded from torch flame. Do not allow torch to contact insulation; it will char at 200°F. NOTE: Products come equipped with an Electronic Defrost Control. To initiate defrost, press and hold air filter and alarm reset key simultainiously for three seconds. To terminate defrost, press and hold air filter and alarm reset key simultainiously for three seconds service data sheet - 297299900 STANDARD - AUTOMATIC DEFROST REFRIGERATOR MODELS (r134a) IMPORTANT: PLEASE RETURN THIS SHEET TO IT'S ORIGINAL LOCATION

  • 1

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
Capacitor Run or
Induction Run
70°F (21°C) Ambient
90°F (32°C) Ambient
Operating Time
10 to 20%
20 to 30%
Refrigerator Temperature
35° to 40° F
2° to 4° C
35° to 40° F
2° to 4° C
Low Side Pressure
(cut-in)
25 to 30 psig
175 to 205 kPa
25 to 30 psig
175 to 205 kPa
Low Side Pressure
(cut-out)
10 to 15 psig
70 to 100 kPa
10 to 15 psig
70 to 100 kPa
High Side Pressure
(last 1/3 cycle)
120 to 130 psig
810 to 880 kPa
175 to 185 psig
1180 to 1260 kPa
Wattage (last 1/3 cycle)
120 to 180
140 to 155
Amps (running)
.8 to 1.3
1.0 to 1.5
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
19’
37° F (3° C)
47° F (8° C)
550
24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
2.3
1100 CW Opposite Shaft
0.13 Running
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S ORIGI-
NAL LOCATION
SERVICE DATA SHEET
-
297299900
STANDARD - AUTOMATIC DEFROST
REFRIGERATOR MODELS (
R134a)
IMPORTANT SAFETY NOTICE
The information provided herein is designed to assist qualified repair
personnel only. Untrained persons should not attempt to make repairs
due to the possibility of electrical shock. Disconnect power cord before
servicing.
IMPORTANT
If any green grounding wires are moved during servicing, they must
be returned to their original position and properly secured.
CAUTION:
All electrical parts and wiring must be shielded
from torch flame. Do not allow torch to contact insulation; it
will char at 200°F.
NOTE:
Products come equipped with an Electronic Defrost Control.
To initiate defrost, press and hold air filter and alarm reset key
simultainiously for three seconds.
To terminate defrost, press and
hold air filter and alarm reset key simultainiously for three seconds