Frigidaire FPRU19F8WF Complete Owners Guide - Page 13
Plastic Water Tubing to, Copper Water Line
View all Frigidaire FPRU19F8WF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
13 WATER SUPPLY CONNECTION To Connect Water Supply Line To Water Inlet Valve 1. Disconnect the refrigerator from electrical power source. 2. Place the end of the water supply line into a sink or bucket. Turn ON the water supply and flush the supply line until the water is clear. Turn OFF the water supply at the shutoff valve. 3. Remove the plastic cap from the water valve inlet and discard the cap. 4. If you use copper tubing - Slide the brass compression nut, and then the ferrule (sleeve) onto the water supply line. Push the water supply line into the water valve inlet as far as it will go (¼"/6.4 mm). Slide the ferrule (sleeve) into the valve inlet and finger tighten the compression nut onto the valve. Tighten another half turn with a wrench; DO NOT overtighten. See Figure 1. If you use braided flexible stainless steel tubing - The nut is already assembled on the tubing. Slide the nut onto the valve inlet and finger tighten the nut onto valve. Tighten another half turn with a wrench; DO NOT overtighten. See Figure 2. A Plastic Water Tubing to Water Dispenser (foamed within the cabinet) B Steel Clamp (Fig. 1: ¼"; Fig. 2: ½") C Brass Compression Nut D Ferrule (Sleeve) E Copper Water Line F Water Valve Bracket G Valve Inlet H Water Valve I Copper Water Line from Household Water Supply* J Braided Flexible Stainless Steel Water Line *Include enough tubing in the loop to allow moving the refrigerator out for cleaning B A C DE G F H I Figure 1 B A C G F H J Figure 2