IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green/yellow grounding wires are removed during servicing, they must be returned to their original position and properly secured. PERFORMANCE AT FACTORY SETTING Ambient Temperature 70°F 90°F Operating Time 28 to 33% 42 to 47% Refrigerator Temperature 33 to 40°F Low Side Pressure (Cut-in) 10.71 to 3.70 psig 10.71 to 5.90 psig Low Side Pressure (Cut-off) -0.09 to -1.74 psig 2.36 to -0.09 psig High Side Pressure 35 to 37 psig 47 to 60 psig Wattage 35W 45W Amps 0.46 0.57 Base Voltage 115 Refrigerant Charge 46g Defrost Heater 206W Cabinet Size: 19´ DEFROST SPECIFICATIONS Thermal Cutout Heater Open Closed Watts Ohms n/a 206 n/a Specifications subject to change without notice. For complete performance data by model, refer to service manual. Options shown are not necessarily part of model. DEFROST CONTROL The defrost period will vary dependent on the heater on time, with a maximum of 60 minutes. There is a 4 minute idle (drip time) time after the heater turns off before the evaporator fan and compressor will turn on. During the defrosting period a temperature sensor monitors the evaporator temperature and the main control board turns the defrost heater off after the frost on the evaporator has melted. A manual defrost can be activated by simultaneously pressing and holding + and AIR FILTER for 10 seconds. The temperature display will show dF for a few seconds indicating manual defrost is activated. A beep will be heard, and then the unit will display the last set point. There may be up to a 3 minute delay before the defrost heater is energized. SERVICE DATA SHEET A16331203 Defrost Heater AUTOMATIC DEFROST UPRIGHT REFRIGERATOR - R600A Dispenser Water Valve IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. SERVICE MODE DIAGNOSTIC TESTS Allows technicians to step through available tests to diagnose individual electrical circuits. To Enter and Exit Service Mode: Press and hold - and + simultaneously for 10 secs Condenser Fan Auxiliary Water Valve Primary Water Valve 120 VAC OUTPUT LOAD TESTS Test Number Load 2 120 VAC, ≈206W 8 120 VAC, ≈15W 12 120 VAC, ≈3.1W 53 120 VAC, 82 ≈15W DIGITAL OUTPUT TESTS Test Number Load Display oF (OFF)/ on (ON) Display Refrigerator LED Lights 13 +12 VDC, ≈21.6W Total oF (OFF)/ on (ON) DC Evaporator Fan 15 +12 VDC, ≈1W oF (OFF) ՈI (MID SPEED) on (FULL SPEED) Controls: Upon entering Service Mode the User Interface illumination test begins. 1. All of the LEDs on the User Interface will illuminate. 2. Press and release + and all of the LEDs on the User Interface will turn off. 3. Press and release + to move to the Output Loads test. Press and release CHILL BOOST to energize load. 4. Pressing and releasing + moves through the Output Loads test, Input tests and Information Display Phase. Press and release - to go back to previous tests. 5. The table provides the test description, test number that is displayed to identify the specific test being performed and the displayed info when the test output or input is activated. Compressor Inverter Speed Control Refrigerator Magnetic Door Switch Icemaker Filtered Water Fill Input Water Dispenser Paddle Switch 38 12 V Square Wave oF (OFF)/ on (ON) DIGITAL INPUT TESTS Test Number Display 23 OP (OPEN)/CL (CLOSED) 27 oF (OFF = NO 12 VDC INPUT) on (ON = 12 VDC INPUT PRESENT) 28 OP (OPEN)/CL (CLOSED) Software Code Streaming During this phase all software parameters and codes which are programmed into the Main Control Board and User Interface board will be displayed in the following order: 1. Main Control Board parameters code (8 characters) 2. Main Control Board software name code (8 characters) 3. User Interface software name code (8 characters) The User Interface displays each character for 1 second, and then the buzzer emits a short beep and displays the next character. • Between the 3 different sets of code displays, the User Interface displays a horizontal bar. • Pressing and releasing + before the software streaming phase is completed the Service Mode goes straight to the lifetime information display phase. • After the software code streaming phase is complete the test automatically goes to the lifetime streaming phase. Lifetime Display During this phase the display shows the total number of days the appliance has been powered up. • Each number is shown on the display starting from the most significant one. Pressing and releasing + makes the buzzer emit a short beep and then display the next digit. • Pressing and releasing + when the fourth digit is displayed makes the Service Mode go straight to the final phase. Final Phase During this phase the User Interface shows a 1-sec upcounting timer. This phase communicates Service Mode has come to an end. To return to normal mode, press and hold - and + simultaneously for 10 secs. TEMPERATURE SENSOR TESTS Test Number Display Refrigerator Cabinet Temp Sensor 29 Main Board Ambient Temp Sensor 33 OP (OPEN)/SH (SHORT) Evaporator Defrost Temp Sensor 39 Error Type ERROR CODES Digit Display Communication error (communica- tion was never achieved at power up or lost communication between main CE board and UI board during normal system run) Refrigerator Cabinet NTC T3 Refrigerator Defrost NTC T2

  • 1
  • 2

SERVICE DATA SHEET
A16331203
AUTOMATIC DEFROST
UPRIGHT REFRIGERATOR - R600A
DEFROST CONTROL
The defrost period will vary dependent on the heater on time, with a maxi-
mum of 60 minutes. There is a 4 minute idle (drip time) time after the heater
turns off before the evaporator fan and compressor will turn on. During the
defrosting period a temperature sensor monitors the evaporator temperature
and the main control board turns the defrost heater off after the frost on the
evaporator has melted.
A manual defrost can be activated by simultaneously pressing and holding
+
and
AIR FILTER
for 10 seconds. The temperature display will show
dF
for
a few seconds indicating manual defrost is activated. A beep will be heard,
and then the unit will display the last set point. There may be up to a 3 minute
delay before the defrost heater is energized.
Specifications subject to change without notice. For complete perfor-
mance data by model, refer to service manual. Options shown are not
necessarily part of model.
PERFORMANCE AT FACTORY SETTING
Ambient Temperature
70°F
90°F
Operating Time
28 to 33%
42 to 47%
Refrigerator Temperature
33 to 40°F
Low Side Pressure (Cut-in)
10.71 to 3.70 psig
10.71 to 5.90 psig
Low Side Pressure (Cut-off)
-0.09 to -1.74 psig
2.36 to -0.09 psig
High Side Pressure
35 to 37 psig
47 to 60 psig
Wattage
35W
45W
Amps
0.46
0.57
Base Voltage
115
Refrigerant Charge
46g
Defrost Heater
206W
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair
personnel only. Untrained persons should not attempt to make repairs due to
the possibility of electrical shock. Disconnect power cord before servicing this
appliance.
IMPORTANT
If any green/yellow grounding wires are removed during servicing, they
must be returned to their original position and
properly secured.
SERVICE MODE DIAGNOSTIC TESTS
Allows technicians to step through available tests to diagnose individual
electrical circuits.
To Enter and Exit Service Mode:
Press and hold
and
+
simultaneously for 10 secs
Controls:
Upon entering Service Mode the User Interface illumination test begins.
1.
All of the LEDs on the User Interface will illuminate.
2. Press and release
+
and all of the LEDs on the User Interface will turn off.
3. Press and release
+
to move to the Output Loads test. Press and release
CHILL BOOST
to energize load.
4.
Pressing and releasing + moves through the Output Loads test, Input
tests and Information Display Phase. Press and release
to go back to
previous tests.
5.
The table provides the test description, test number that is displayed to
identify the specific test being performed and the displayed info when
the test output or input is activated.
IMPORTANT: PLEASE RETURN THIS SHEET TO
ITS ORIGINAL LOCATION.
DEFROST SPECIFICATIONS
Cabinet Size: 19´
Thermal Cutout
Heater
Open
Closed
Watts
Ohms
n/a
206
n/a
120 VAC OUTPUT LOAD TESTS
Test Number
Load
Display
Defrost Heater
2
120 VAC,
≈206W
oF (OFF)/
on (ON)
Dispenser Water
Valve
8
120 VAC,
≈15W
Condenser Fan
12
120 VAC,
≈3.1W
Auxiliary Water
Valve
53
120 VAC,
≈15W
Primary Water
Valve
82
DIGITAL OUTPUT TESTS
Test Number
Load
Display
Refrigerator LED
Lights
13
+12 VDC,
21.6W Total
oF (OFF)/
on (ON)
DC Evaporator
Fan
15
+12 VDC,
1W
oF (OFF)
Ո
I (MID SPEED)
on (FULL SPEED)
Compressor
Inverter Speed
Control
38
12 V Square Wave
oF (OFF)/
on (ON)
DIGITAL INPUT TESTS
Test Number
Display
Refrigerator Mag-
netic Door Switch
23
OP (OPEN)/CL (CLOSED)
Icemaker Filtered
Water Fill Input
27
oF (OFF = NO 12 VDC INPUT)
on (ON = 12 VDC INPUT PRESENT)
Water Dispenser
Paddle Switch
28
OP (OPEN)/CL (CLOSED)
TEMPERATURE SENSOR TESTS
Test Number
Display
Refrigerator Cabinet
Temp Sensor
29
OP (OPEN)/SH (SHORT)
Main Board Ambient
Temp Sensor
33
Evaporator Defrost
Temp Sensor
39
Software Code Streaming
During this phase all software parameters and codes which are programmed
into the Main Control Board and User Interface board will be displayed in the
following order:
1.
Main Control Board parameters code (8 characters)
2.
Main Control Board software name code (8 characters)
3.
User Interface software name code (8 characters)
The User Interface displays each character for 1 second, and then the buzzer
emits a short beep and displays the next character.
Between the 3 different sets of code displays, the User Interface displays a
horizontal bar.
Pressing and releasing
+
before the software streaming phase is completed
the Service Mode goes straight to the lifetime information display phase.
After the software code streaming phase is complete the test automatically
goes to the lifetime streaming phase.
Lifetime Display
During this phase the display shows the total number of days the appliance has
been powered up.
Each number is shown on the display starting from the most significant
one. Pressing and releasing
+
makes the buzzer emit a short beep and then
display the next digit.
Pressing and releasing
+
when the fourth digit is displayed makes the
Service Mode go straight to the final phase.
Final Phase
During this phase the User Interface shows a 1-sec upcounting timer.
This phase communicates Service Mode has come to an end. To return to
normal mode, press and hold
and
+
simultaneously for 10 secs.
ERROR CODES
Error Type
Digit Display
Communication error (communica-
tion was never achieved at power up
or lost communication between main
board and UI board during normal
system run)
CE
Refrigerator Cabinet NTC
T3
Refrigerator Defrost NTC
T2