Frigidaire FPUH19D7LF Complete Owner's Guide (English) - Page 7

Leveling Instructions - trim kit for

Page 7 highlights

LEVELING INSTRUCTIONS To Level The Freezer: While unit is lying on its back for wood skid removal, note the location of the four (4) leg levelers installed at each corner. These leg levelers will be used to level the freezer and to adjust the height. Use a carpenter's level to level the freezer from front to back and side to side.  NOTE Make sure to allow for the Trim and Leveling Kit if it is to be installed with the unit. Level Front to Back & Side to Side • Slide second unit into place leaving a minimum gap of 3/16" between units for door swing clearance. • This last step may require at least one extraction of the second unit to properly align units in a "built-in" application. Leveling Door with Adjustable Hinge Use the lower hinge adjustment to fine tune the door height and for final cabinet spacing. Use a 7/16" socket or wrench to adjust the screw at the bottom of the lower hinge. Adjusting Doors For Matching Tall Refrigerator / Tall Freezer Pair The doors may also be adjusted side to side with the slotted hinge for aligning the doors parallel to each other. Loosen the two bolts with a 3/8" wrench and one screw with a Phillips screwdriver. Shift the doors until parallel, then retighten the screws securely. (See illustration below.) Lower Hinge Adjustment For Leveling The Doors Of The Matching Tall Refrigerator / Tall Freezer Pair To level the doors using the adjustable lower hinge (some models): 1. If the freezer door is lower than the freezer door, raise the freezer door by turning the adjustment screw clockwise using a 7/16 inch socket wrench. (See illustration below.) 2. If the freezer door is lower than the freezer door, raise the freezer door by turning the adjustment screw clockwise using a 7/16 inch socket wrench. (See illustration below.) Leveling Instructions For Matching Tall Freezer / Tall Freezer Pair: • Level door of first unit using all four levelers and slide unit into place. Recheck for levelness and adjust if necessary. • Measure distance from floor to bottom of door on first unit. Adjust and level second unit so door height matches. • Leg Level Adjustments: • One full turn of all four leg levelers will raise door 5/32". Freezer Slotted Hinge Adjustment 3/8" Bolts Screw Refrigerator 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

7
LEVELING INSTRUCTIONS
To Level The Freezer:
While unit is lying on its back for wood skid removal,
note the location of the four (4) leg levelers installed at
each corner.
These leg levelers will be used to level the
freezer and to adjust the height.
Use a carpenter’s level
to level the freezer from front to back and side to side.
Leveling Instructions For Matching Tall
Freezer / Tall Freezer Pair:
Level door of
rst unit using all four levelers and slide
unit into place.
Recheck for levelness and adjust if
necessary.
Measure distance from
oor to bottom of door on
rst unit.
Adjust and level second unit so door height
matches.
Leg Level Adjustments:
One full turn of all four leg levelers will raise door
5/32”.
Slide second unit into place leaving a minimum
gap of 3/16” between units for door swing clearance.
This last step may require at least one extraction of
the second unit to properly align units in a “built-in”
application.
Leveling Door with Adjustable Hinge
Use the lower hinge adjustment to
ne tune the door
height and for
nal cabinet spacing.
Use a 7/16” socket
or wrench to adjust the screw at the bottom of the lower
hinge.
Adjusting Doors For Matching Tall
Refrigerator / Tall Freezer Pair
The doors may also be adjusted side to side with the
slotted hinge for aligning the doors parallel to each other.
Loosen the two bolts with a 3/8” wrench and one screw
with a Phillips screwdriver.
Shift the doors until parallel,
then retighten the screws securely.
(See illustration
below.)
Refrigerator
Freezer
3/8” Bolts
Screw
Slotted Hinge
Adjustment
Level Front to Back
& Side to Side
Lower Hinge Adjustment For Leveling The
Doors Of The Matching Tall Refrigerator /
Tall Freezer Pair
To level the doors using the adjustable lower hinge (some
models):
1.
If the freezer door is lower than the freezer door,
raise the freezer door by turning the adjustment
screw clockwise using a 7/16 inch socket wrench.
(See illustration below.)
2.
If the freezer door is lower than the freezer door,
raise the freezer door by turning the adjustment
screw clockwise using a 7/16 inch socket wrench.
(See illustration below.)
NOTE
Make sure to allow for the Trim and Leveling Kit if it is
to be installed with the unit.