Frigidaire FRE5711KW Installation Instructions (All Languages) - Page 10
Gas connection, Electrical connection non-Canada 3-wire cord - service manual
UPC - 012505380716
View all Frigidaire FRE5711KW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Gas connection 1. Remove the shipping cap from gas pipe at the rear of the dryer. DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician. 2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections. Manual Shutoff Flare Valve Union GAS FLOW Flare Union 3. Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line. to dryer Shutoff Valve Open position from gas supply Closed Nipple Open Flexible Connector Inlet Pipe on Back of Dryer All connections must be wrench-tightened The supply line must be equipped with an approved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the gas shutoff valve. 4. Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing on a soapy water solution. - EXPLOSION HAZARD - NEVER test for gas leaks with an open flame. Electrical connection (non-Canada) 3-wire cord - ELECTRICAL SHOCK HAZARD - Failure to disconnect power source before servicing could result in personal injury or even death. 1. Turn off power supply to outlet. 2. Remove the screw securing the terminal block access cover in the upper corner on the back of the dryer. 3. Install a UL-approved strain relief according to the power cord/ strain relief manufacturer's instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place. 4. Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief. 5. Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely. 6. Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely. - ELECTRICAL SHOCK HAZARD - Do not make a sharp bend or crimp wiring/conductor at connections. 3-wire receptacle (NEMA type 10-30R) 30 AMP NEMA 10-30 DO NOT remove internal ground in a 3-wire system! Neutral (center wire) Neutral terminal 7. Follow manufacturer's guidelines for firmly securing the strain relief and power cord. 8. Reinstall the terminal block cover. 10 If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block.