Frigidaire atf7000fe Data Sheet - Page 2
Error code chart - error code e41
UPC - 012505376948
View all Frigidaire atf7000fe manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Error code Error code chart Fault condition E11 Fill time too long. E13 Water leak in tub or air leak in air bell. E21 Water not pumping out fast enough. E23 Drain pump relay on control board failed or wire off pump. E24 Drain pump relay on control board failed or wire off pump. E31 Pressure sensor not communicating with control board. E35 Pressure sensor indicates water overfill. E36 Control board problem. E41 Control board thinks the door switch is open. E43 Control board problem. E44 Control board problem. E45 Control board problem. E46 Control board problem. E47 Board thinks the door PTC circuit is open in spin. E48 Board thinks the door PTC circuit is closed. E52 Bad signal from tacho generator. E56 High motor current. E57 High current on inverter. E58 High current on motor phase. E59 No tacho signal for 3 seconds. E5A High temperature on heat sink caused by overloading. E5B High temperature on heat sink. E5C High temperature on heat sink. E5D Communication problem. E5E Communication problem. E5F Communication problem. E66 Heating element relay failure. E67 Input voltage on microprocessor incorrect. E68 Current leakage to ground on heater or fuse opened. E71 Wash NTC failure. (Tub heater) E74 Wash temperature does not increase. E75 Water temperature sensor circuit. E76 NTC temperature for the cold water valve over the limits. E82 Console control problem. E83 Console control problem. E91 Comunnication error between UI board and control board. E93 Console control problem. E94 Console control problem. E95 Communication error. E97 Console control problem. E98 Console control problem. EB1 Incoming power frequency out of limits. EB2 Incoming line voltage above 130 VAC. EB3 Incoming line voltage below 90 VAC. EF1 Clogged drain pump. EF2 Too much soap. EBE Console control problem. EBF Console control problem. EF5 NTC temperature for the hot water valve over the limits. Check Refer to test (1). Refer to test (2). Refer to test (3). Replace control board or wire. Replace control board or wire. Refer to test (4). Refer to test (5). Replace the control board. Refer to test (6). Replace the control board. Replace the control board. Replace the control board. Replace the control board. Refer to test (7). Refer to test (7). Refer to test (8). Refer to test (9). Refer to test (9). Refer to test (9). Refer to test (10). Test first-if bad-rpl speed control brd. Replace the speed control board. Replace the speed control board. Refer to test (11). Refer to test (11). Refer to test (11). Refer to test (14). Refer to test (15). Refer to test (14). Replace control board or wire. Place NTC in correct position. Refer to test (12). Hot and cold water hoses switched. Replace the control board. Replace the control board. Check wiring. Replace the control board. Replace the control board. Replace the control board. Replace the control board. Replace the control board. Refer to test (13) Check voltage at the outlet. If below 130 VAC, replace the control board. Check voltage at the outlet. If above 90 VAC, replace the control board. Unclog the drain pump. Advise customer to reduce the amount of soap they are using. Replace the control board. Replace the control board. Hot and cold water hoses switched. 134879700A (0702) 2