Fujitsu FI 5120C Getting Started Guide - Page 26
Appendix2 - scanner rollers
UPC - 000057129044
View all Fujitsu FI 5120C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Appendix2 DAILY CARE WARNING The glass surface inside the ADF becomes hot during the operation. Before you clean inside the scanner, turn off its power and unplug the AC adapter from the outlet. Wait for at least 15 minutes. Do not turn off the scanner when you clean the Feed rollers. ■ Cleaning Materials Cleaning Materials Cleaner F1 (or isopropyl alcohol) Lint-free dry cloth Parts Number Remarks CA995010013 1 bottle Moisten the cloth with this fluid and wipe the scanner clean. (*) Commercially available one * For details about cleaning materials, contact the FUJITSU scanner dealer where you purchased the scanner. ■ Cleaning Method The ADF must be cleaned with a lint-free cloth moistened with the Cleaner F1. ■ Parts to Clean and When Part to clean Pad ASSY Pick roller Feed rollers Plastic rollers Glass Standard Cleaning Cycle Clean these parts after every 1,000 scans. ATTENTION The scanner must be cleaned frequently if you scan any of the following type of paper sheets: • Documents of coated paper • Documents that are almost completely covered with printed text or graphics • Chemically treated documents such as carbonless paper • Documents containing a large amount of calcium carbonate • Handwritten documents For details on the cleaning the ADF, refer to "3.3 Cleaning the ADF" in fi-5120C/fi-5220C Operator's Guide on the Setup CD-ROM". AP-4