Fujitsu MAV2036RC Manual/User Guide - Page 8

AC noise filter recommended, Connection Requirements, Connector, Connector

Page 8 highlights

Installation Requirements (5) Noise filter To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the HDD power supply unit. The specification of this noise filter is as follows: • Attenuation: 40 dB or more at 10 MHz • Circuit construction: T-configuration as shown in Figure 4.8 is recommended. Figure 4.8 AC noise filter (recommended) 4.3 Connection Requirements 4.3.1 Connector Figure 4.9 shows the locations of interface connector. Interface connector (CN1) (power lines included) Figure 4.9 Connector location 4-8 C141-E219

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Installation Requirements
4-8
C141-E219
(5)
Noise filter
To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the HDD
power supply unit.
The specification of this noise filter is as follows:
Attenuation: 40 dB or more at 10 MHz
Circuit construction:
T-configuration as shown in Figure 4.8 is recommended.
Figure 4.8
AC noise filter (recommended)
4.3
Connection Requirements
4.3.1
Connector
Figure 4.9 shows the locations of interface connector.
Interface connector (CN1)
(power lines included)
Figure 4.9
Connector location