5.3 Host Commands Table 5.4 Information to be read by IDENTIFY DEVICE command (2 of 6) Word 23-26 27-46 47 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 66 67 68 69-79 80 81 82 Value - Set by a device X'8010' X'0000' X'0B00' X'0000' X'0200' X'0000' X'0007' (Variable) (Variable) (Variable) (Variable) *6 *2 X'0000' X'xx07' X'0003' X'0078' X'0078' X'00F0' X'0078' X'0000' X'001E' X'0000' X'346B' Description Firmware revision (ASCII code, 8 characters, left) Model name (ASCII code, 40 characters, left) Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command Reserved Capabilities *3 Reserved PIO data transfer mode *4 Reserved Enable/disable setting of words 54-58 and 64-70, 88 *5 Number of current Cylinders Number of current Head Number of current sectors per track Total number of current sectors Transfer sector count currently set by READ/WRITE MULTIPLE command *6 Total number of user addressable sectors (LBA mode only) *2 Reserved Multiword DMA transfer mode *7 Advance PIO transfer mode support status *8 Minimum multiword DMA transfer cycle time per word : 120 [ns] Manufacturer's recommended DMA transfer cycle time : 120 [ns] Minimum PIO transfer cycle time without IORDY flow control : 240 [ns] Minimum PIO transfer cycle time with IORDY flow control : 120 [ns] Reserved Major version number *9 Minor version number (not reported) Support of command sets *10 C141-E070-01EN 5-33