Garmin GPSMAP 4010 Technical Reference for Garmin NMEA 2000 Products - Page 34
Configuring the NMEA 2000 Tank Capacity, Calibrating the Fluid Level, Troubleshooting the Tank Number
View all Garmin GPSMAP 4010 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
NMEA 2000 Checklist • For other Garmin marine devices, select Config > Tank Number. 3. Select a tank number. 4. Select OK. Configuring the NMEA 2000 Tank Capacity You can indicate the capacity of the fluid tank that the GFL 10 adapter is associated with. 1. From the NMEA 2000 Devices list, select the GFL 10 device. 2. Select an option: • For most Garmin chartplotters, select Review > N2K Tank Capacity. • For other Garmin marine devices, select Config > N2K Tank Capacity. 3. Select the tank capacity. 4. Select Done. Calibrating the Fluid Level To use the GFL 10 adapter, you must calibrate the fluid level of the tank that the adapter is associated with, using a minimum of two calibration points. The greater the number of fluid calibration points, the greater the accuracy of the reading on the fluid-level gauge. 1. Turn the boat ignition key to the On position (not Start). 2. From the NMEA 2000 Devices list, select the GFL 10 device. 3. Select an option: • For most Garmin chartplotters, select Review > Level Calibration > Add Calibration Point. • For other Garmin marine devices, select Config > Level Calibration > Add Calibration Point. 4. Select the percentage of fluid currently in the tank, based on the total tank capacity. 5. Select Done. 6. Change the level of the fluid in the tank. 7. Select Add Calibration Point. 8. Select the percentage of fluid currently in the tank, based on the total tank capacity. 9. Select Done. 10.Repeat steps 6 through 9 to add additional, optional fluid-level calibration points. Troubleshooting the Tank Number If multiple GFL 10 adapters are assigned to the same NMEA 2000 fluid type, each adapter is assigned a unique tank number automatically. If the "Invalid NMEA 2000 tank configuration" error message appears, you must assign a unique tank number to each adapter. For example, if two adapters are assigned the NMEA 2000 fluid type value of Live Well and the error message appears, you must assign each adapter a unique tank number. 1. From the NMEA 2000 Devices list, select the GFL 10 device. 2. Select an option: • For most Garmin chartplotters, select Review > Tank Number. • For other Garmin marine devices, select Config > Tank Number. 3. Select a tank number. 4. Select OK. Troubleshooting the Gauge Type When connected to a gauge, the GFL 10 adapter gauge type is set to Auto Detect by default, and the adapter automatically detects the type of gauge it is connected to. If the fluid-level reading on a connected Garmin chartplotter or marine instrument changes with the engine RPM, the adapter may be detecting the wrong type of gauge. NOTE: The fluid level changes when the boat is moving. Test the gauge-type setting when the boat is not moving. 30 Technical Reference for Garmin NMEA 2000 Products