Garmin GSD 28 Sonar Module Installation Instructions - Page 8

Dual-Element Transducers, Two Single-Element Transducers

Page 8 highlights

Dual-Element Transducers NOTICE Connecting the high-frequency wires to the low-frequency terminal block, or the low-frequency wires to the high-frequency terminal block, damages the device and the transducer. For dual-element transducers, the low-frequency element wires must be connected to the terminals labelled LOW and the high-frequency element wires must be connected to the terminals labelled HIGH. Ground (GRND), temperature (TEMP), XID and GID wires can be connected to either set of terminals. Two Single-Element Transducers To ensure proper transducer identification and safe operation, you must connect each single-element transducer to its own set of terminals. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Dual-Element Transducers
NOTICE
Connecting the high-frequency wires to the low-frequency terminal block, or the low-frequency wires to the
high-frequency terminal block, damages the device and the transducer.
For dual-element transducers, the low-frequency element wires must be connected to the terminals labelled
LOW and the high-frequency element wires must be connected to the terminals labelled HIGH. Ground (GRND),
temperature (TEMP), XID and GID wires can be connected to either set of terminals.
Two Single-Element Transducers
To ensure proper transducer identification and safe operation, you must connect each single-element
transducer to its own set of terminals.