GE AJEQ10DCD Use and Care Manual - Page 12

Before You Begin - appliances

Page 12 highlights

Installation Instructions Air Conditioner Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. • IMPORTANT - Save these instructions for local inspector's use. • IMPORTANT - Observe all governing codes and ordinances. • Note to Installer - Be sure to leave these instructions with the Consumer. • Note to Consumer - Keep these instructions for future reference. • Skill level - Installation of this appliance requires basic mechanical skills. • Completion time - Approximately 1 hour • We recommend that two people install this product. • Proper installation is the responsibility of the installer. • Product failure due to improper installation is not covered under the Warranty. ELECTRICAL REQUIREMENTS WARNING! Risk of electric shock. Can cause injury or death. This appliance must be properly grounded. Where a 2-prong wall outlet is encountered, it is your responsibility and obligation to have it replaced with a properly grounded 3-prong outlet. Some models require a 115/120-volt a.c., 60-Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Do not change the plug on the power cord of this air conditioner. Aluminum house wiring may present special problems-consult a qualified electrician. ELECTRICAL REQUIREMENTS (cont.) Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires. IMPORTANT! GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty. J-MODEL QUALIFYING QUESTIONS J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart on the next page for the proper kit. A What brand air conditioner will you be replacing? B What are the dimensions of the wall case currently in use? C What is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use? Frequently, the J-model adapter kit will apply to another brand model "series" or specific vintage. In these cases, you need the chassis model number and/or the wall case or "type" number to confirm the use of the correct adapter kit. D What type of outdoor grille is used with the current wall case? There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

ELECTRICAL REQUIREMENTS
WARNING!
Risk of electric shock. Can
cause injury or death. This appliance must be
properly grounded. Where a 2-prong wall outlet
is encountered, it is your responsibility and
obligation to have it replaced with a properly
grounded 3-prong outlet.
Some models require a 115/120-volt a.c.,
60-Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of
electric shock hazard. If the wall outlet you plan to use is
only a 2-prong outlet, it is your responsibility to have it
replaced with a properly grounded 3-prong wall outlet.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT
Save these instructions
for local inspector’s use.
IMPORTANT
Observe all governing codes
and ordinances.
Note to Installer –
Be sure to leave these instructions
with the Consumer.
Note to Consumer –
Keep these instructions
for future reference.
Skill level –
Installation of this appliance requires basic
mechanical skills.
Completion time –
Approximately 1 hour
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation
is not covered under the Warranty.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
Installation
Air Conditioner
Instructions
12
ELECTRICAL REQUIREMENTS (cont.)
Some models require 230/208-volt a.c., protected
with a time delay fuse or circuit breaker. These
models should be installed on their own single
branch circuit for best performance and to prevent
overloading house or apartment wiring circuits,
which could cause a possible fire hazard from
overheating wires.
IMPORTANT!
GE strongly recommends the removal of the old wall case
and the installation of a new GE Wall Case. If you decide to
keep the existing wall case, you may need a kit to ensure
proper performance. If you DO NOT use a kit, you run the
risk of poor performance or product failure. This is not
covered under the terms of the GE warranty.
J-MODEL QUALIFYING QUESTIONS
J-model air conditioners may fit in existing wall cases.
However, they often need a kit to properly adapt the case
to the GE air conditioner. Answer these questions and see
the chart on the next page for the proper kit.
What brand air conditioner will you be replacing?
What are the dimensions of the wall case currently
in use?
What is the model number of the chassis
currently in use? What is the model (or Type) number
of the wall case currently in use?
Frequently, the J-model adapter kit will apply to another
brand model “series” or specific vintage. In these cases,
you need the chassis model number and/or the wall
case or “type” number to confirm the use of the correct
adapter kit.
What type of outdoor grille is used with the current
wall case?
There may be an architectural grille attached to a wall
case to enhance the exterior appearance of the building.
Custom grilles may be used with J-model wall cases
provided a J-model adapter kit is also used to ensure
proper airflow.
D
C
B
A