Installation Instructions, EXHAUSTING THE DRYER cont.
UPC - 084691079354
View all GE DPGT750ECWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Installation Instructions EXHAUSTING THE DRYER (cont.) WARNING USE ONLY METAL 4" DUCT. DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE. Ducting longer than 150 equivalent feet will: • Increase the drying times and the energy cost. • Reduce the dryer life. • Accumulate lint, creating a potential fire hazard. EXAMPLE ONLY The following chart describes an example of one possible ductwork installation. The correct exhaust installation is your responsibility. Problems due to incorrect installation are not covered by the warranty. The length of the exhaust system depends upon the type of duct, number of turns and the type of exhaust hood (wall cap), and all conditions noted below. For satisfactory air movement, the total duct length should not exceed 150 equivalent feet. DUCT PIECES EQUIVALENT RIGID NUMBER LENGTH X USED Rigid Metal Ducting (Preferred) 1 Ft. X (4) EQUIVALENT = LENGTH = 4 Ft. TRANSITION DUCTING (DRYER TO WALL) INSIDE WALLS/CEILING (WALL TO WALL CAP) Elbows (90°/45°) 10 Ft. X (3) = Turns Less 2 Ft. X (1) = Than 4 Ft. Less Than 4 Ft. Rigid Ducting 1 Ft. X (5) = 4" Wall Cap 5 Ft. X (1) = 4" (10.2 cm) Total Ductwork Length = TOTAL MUST BE LESS THAN OR EQUAL TO 150 FT. 30 30 Ft. 2 Ft. 5 Ft. 5 Ft. 46 Ft. WALL CAPS