ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES GROUNDING INSTRUCTIONS The operating voltage (Volts), Amperage (Amps) and Frequency (Hz) of this dryer are indicated on the Rating Plate located to the right of the loading port. Connect this dryer to a circuit corresponding to that indicated on rating plate and protected by fuses or a circuit breaker in accordance with local codes. Use a power supply cord kit marked for use with clothes dryer. This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electrical current. WARNING: Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is For 208V and 240V models, use a power supply cord kit marked for use properly grounded. with clothes dryers. Do not modify the plug provided with the appliance - if it will not fit the DO NOT USE EXTENSION CORD WITH THIS APPLIANCE outlet, have a proper outlet installed by a qualified electrician. For alternate 208V or 240V power supply hook-up, proceed as follows: Remove rear access panel. Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation. WARNING: Appliance grounded to neutral conductor through a link. If used in a mobile home or if local codes do not permit grounding through neutral, a 4-conductor cord or cable assembly for use with clothes dryers must be used with the following specifications: Type St. Cable, 125/250 Min Volt, 30 Amp with closed-loop terminals and secured with a UL recognized strain relief. See manufacturer's instructions Make sure screws on terminal block are tight. FOR THREE-WIRE SUPPLY (208V & 240V MODELS) Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block. Connect Neutral line to center screw (N) of terminal block. REAR HOT WIRE GREEN GROUNDING SCREW GROUND STRAP L1 N HOT WIRE WHITE NEUTRAL WIRE L 2 208V or 240V FRONT INSIDE TOP VIEW OF DRYER POWER SUPPLY CORD 3#10 AWG MINIMUM COPPER CONDUCTORS 30 AMP, 240V, WITH TYPE UL RECOGNIZED MINIMUM RATED 90°C 208 OR 240 VOLT OPERATION 120/208 OR 120/240 VOLT SUPPLY (USE ONLY 30 AMP FUSES) FOR FOUR-WIRE SUPPLY (208V & 240V MODELS) Remove ground strap and discard. Rescrew green grounding screw in place. Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block. Connect NEUTRAL line to center screw (N) of terminal block. Attach ground wire of power supply to green grounding screw beside terminal block. REAR GREEN OR YELLOW GROUND WIRE GREEN GROUNDING SCREW HOT WIRE WHITE NEUTRAL WIRE POWER SUPPLY CORD 4 #10 AWG MINIMUM COPPER CONDUCTORS, 30 AMP, 240V, WITH CLOSED-LOOP TERMINALS TYPE UL RECOGNIZED MINIMUM RATED 90°C. HOT WIRE L1 N L2 208V or 240V FRONT REMOVE GROUND STRAP AND DISCARD 208 OR 240 VOLT OPERATION 120/208 OR 120/240 VOLT SUPPLY (USE ONLY 30 AMP FUSES) FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Properly strain relief the cord set or cable to the cable entry hole with UL recognized strain relief. Make sure cordset or the cable is away from the rotating drum. Replace access panel. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Properly strain relief the cord set or cable to the cable entry hole with UL recognized strain relief. Make sure cordset or the cable is away from the rotating drum. Replace access panel. 3 WIRE RECEPTACLE (10-30R) Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail). X G W Y 4-WIRE RECEPTACLE (14-30R) Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail). 4-CONDUCTOR CORD ASSEMBLY ( Type ST Cable) Typical 30 amp cord assembly for use where local codes do not permit grounding through neutral. PAGE 2

  • 1
  • 2
  • 3
  • 4

PAGE 2
ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
GROUNDING INSTRUCTIONS
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
FOR THREE-WIRE SUPPLY
FOR FOUR-WIRE SUPPLY
(208V & 240V MODELS)
(208V & 240V MODELS)
The operating voltage (Volts), Amperage (Amps) and Frequency
(Hz) of this dryer are indicated on the Rating Plate located to the
right of the loading port.
Connect this dryer to a circuit corresponding to that indicated on
rating plate and protected by fuses or a circuit breaker
in accordance with local codes.
Use a power supply cord kit marked for use with clothes dryer.
For 208V and 240V models, use a power supply cord kit marked for use
with clothes dryers.
Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block.
Connect Neutral line to center screw (N) of terminal block.
Remove ground strap and discard. Rescrew green grounding screw in
place.
Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block.
Connect NEUTRAL line to center screw (N) of terminal block.
Attach ground wire of power supply to green grounding screw beside
terminal block.
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
Typical 30 amp receptacle for use
where
local codes
permit use
of
flexible
type
power
supply
cord (pigtail).
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through
neutral.
Properly strain relief the cord set or cable to the cable entry hole with
UL recognized strain relief.
Make sure cordset or the cable is away from the rotating drum.
Replace access panel.
Properly strain relief the cord set or cable to the cable entry hole with
UL recognized strain relief.
Make sure cordset or the cable is away from the rotating drum.
Replace access panel.
POWER SUPPLY CORD 3#10
AWG MINIMUM COPPER
CONDUCTORS
30 AMP, 240V, WITH
TYPE UL RECOGNIZED
MINIMUM RATED 90°C
208 OR 240
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
(USE ONLY
30 AMP FUSES)
REMOVE GROUND
STRAP AND DISCARD
208 OR 240
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
(USE ONLY
30 AMP FUSES)
4-WIRE RECEPTACLE
(14-30R)
4-CONDUCTOR CORD
ASSEMBLY ( Type ST Cable)
POWER SUPPLY CORD 4 #10
AWG MINIMUM COPPER
CONDUCTORS, 30 AMP, 240V,
WITH CLOSED-LOOP TERMINALS
TYPE UL RECOGNIZED MINIMUM
RATED 90°C.
REAR
HOT WIRE
HOT WIRE
FRONT
208V or 240V
GREEN
GROUNDING
SCREW
WHITE
NEUTRAL
WIRE
GROUND
STRAP
L
1
L
2
N
INSIDE TOP VIEW OF DRYER
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
3 WIRE RECEPTACLE
(10-30R)
Remove rear access panel.
Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation.
WARNING:
Appliance grounded to neutral conductor through a link. If used in a mobile home or if local codes do not permit grounding through neutral, a
4-conductor cord or cable assembly for use with clothes dryers must be used with the following specifications: Type St. Cable, 125/250 Min Volt, 30 Amp
with closed-loop terminals and secured with a UL recognized strain relief. See manufacturer’s instructions
Make sure screws on terminal block are tight.
For alternate 208V or 240V power supply hook-up, proceed as follows:
This
appliance
must
be
grounded.
In
the
event
of
malfunction
or
breakdown, grounding will reduce the risk of
electric shock by providing
a path of least resistance for electrical current.
WARNING:
Improper connection of the equipment grounding conductor
can result in a risk of
electric
shock. Check with a qualified electrician
or serviceman if you are in doubt as to whether the appliance is
properly grounded.
Do not modify the plug provided with the appliance - if it will not fit the
outlet, have a proper outlet installed by a qualified electrician.
REAR
HOT WIRE
HOT WIRE
FRONT
208V or 240V
GREEN
GROUNDING
SCREW
WHITE
NEUTRAL
WIRE
GREEN OR YELLOW
GROUND WIRE
L
1
L
2
N
X
W
G
Y